SCANNING TRANSMISSION ELECTRON MICROSCOPY FOR QUANTITATIVE MAPPING OF MACROELEMENT CONTENTS OF CARDIAC TISSUE

Aim. Development of semiquantitative and quantitative nondestructing method to analyze the spread of chemical elements in myocardium mass up to 100 mg (autopsy).Material and methods. The development was performed on biological specimens of cardiac autopsy of 18 healthy persons without cardiovascular...

Full description

Saved in:
Bibliographic Details
Main Authors: A. A. Komisov, O. A. Osipova, R. N. Shepel, O. M. Drapkina, P. G. Osipov, K. G. Plaksina, N. V. Malay
Format: Article
Language:Russian
Published: «FIRMA «SILICEA» LLC 2016-12-01
Series:Российский кардиологический журнал
Subjects:
Online Access:https://russjcardiol.elpub.ru/jour/article/view/724
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849249844118421504
author A. A. Komisov
O. A. Osipova
R. N. Shepel
O. M. Drapkina
P. G. Osipov
K. G. Plaksina
N. V. Malay
author_facet A. A. Komisov
O. A. Osipova
R. N. Shepel
O. M. Drapkina
P. G. Osipov
K. G. Plaksina
N. V. Malay
author_sort A. A. Komisov
collection DOAJ
description Aim. Development of semiquantitative and quantitative nondestructing method to analyze the spread of chemical elements in myocardium mass up to 100 mg (autopsy).Material and methods. The development was performed on biological specimens of cardiac autopsy of 18 healthy persons without cardiovascular pathology died in traffic accidents. Biological specimens were divided into 3 parts, of those 2 parts by1 gand one —0,1 g, respectively. Parts of1 gmass were used for reference range grounding and fine tune of the detector, and the0,1 gpart was the studied specimen. Preparation of specimens was done by standard methodology. The results of macroelements concentration measurement were taken as reference range. Mapping of element contents was done with nanotechnologies: scanning (SEM FEIQuanta 200) and scanning-transmission (STEM; FEI NovaNanoSEM) electronic microscopy.Results. As a result of the study, first time the method for quality improvement was defined for the mapping of macroelementary contents of biological specimens, i. e. tissues of human organs, with x-ray fluorescent analysis. The data makes it to study the spread of microand macroelements in myocardium that provides benefits in comparatory analysis, assessing dislocations, foci of pathological concentrations of elements in tissues of cardiovascular patients.Conclusion. The method of macroelement contents mapping of biological specimens with x-ray fluorescence makes it to improve the precision of mapping of macroelementary contents in biological specimens 100 times up to 10-30 ppm, which is itself a quantitative mapping, and has benefits for practical implication in clinical medicine. The data makes it to study the spread of microand macroelements in myocardium, which opens the opportunity to do comparison of the spread, foci and regions of pathological concentration of chemical elements in the tissue of cardiovascular patients.
format Article
id doaj-art-85d818845e7d414c8867a8ae63dbbf46
institution Kabale University
issn 1560-4071
2618-7620
language Russian
publishDate 2016-12-01
publisher «FIRMA «SILICEA» LLC
record_format Article
series Российский кардиологический журнал
spelling doaj-art-85d818845e7d414c8867a8ae63dbbf462025-08-20T03:57:26Zrus«FIRMA «SILICEA» LLCРоссийский кардиологический журнал1560-40712618-76202016-12-01012182210.15829/1560-4071-2016-12-18-22699SCANNING TRANSMISSION ELECTRON MICROSCOPY FOR QUANTITATIVE MAPPING OF MACROELEMENT CONTENTS OF CARDIAC TISSUEA. A. Komisov0O. A. Osipova1R. N. Shepel2O. M. Drapkina3P. G. Osipov4K. G. Plaksina5N. V. Malay6Belgorod State National Research UniversityBelgorod State National Research UniversityI.M. Sechenov First Moscow State Medical UniversityNational Research Center for Preventive Medicine of the Ministry of HealthBelgorod State National Research UniversityBelgorod State National Research UniversityBelgorod State National Research UniversityAim. Development of semiquantitative and quantitative nondestructing method to analyze the spread of chemical elements in myocardium mass up to 100 mg (autopsy).Material and methods. The development was performed on biological specimens of cardiac autopsy of 18 healthy persons without cardiovascular pathology died in traffic accidents. Biological specimens were divided into 3 parts, of those 2 parts by1 gand one —0,1 g, respectively. Parts of1 gmass were used for reference range grounding and fine tune of the detector, and the0,1 gpart was the studied specimen. Preparation of specimens was done by standard methodology. The results of macroelements concentration measurement were taken as reference range. Mapping of element contents was done with nanotechnologies: scanning (SEM FEIQuanta 200) and scanning-transmission (STEM; FEI NovaNanoSEM) electronic microscopy.Results. As a result of the study, first time the method for quality improvement was defined for the mapping of macroelementary contents of biological specimens, i. e. tissues of human organs, with x-ray fluorescent analysis. The data makes it to study the spread of microand macroelements in myocardium that provides benefits in comparatory analysis, assessing dislocations, foci of pathological concentrations of elements in tissues of cardiovascular patients.Conclusion. The method of macroelement contents mapping of biological specimens with x-ray fluorescence makes it to improve the precision of mapping of macroelementary contents in biological specimens 100 times up to 10-30 ppm, which is itself a quantitative mapping, and has benefits for practical implication in clinical medicine. The data makes it to study the spread of microand macroelements in myocardium, which opens the opportunity to do comparison of the spread, foci and regions of pathological concentration of chemical elements in the tissue of cardiovascular patients.https://russjcardiol.elpub.ru/jour/article/view/724x-ray fluorescent analysismacroelementsmicroelementsmyocardiummapping
spellingShingle A. A. Komisov
O. A. Osipova
R. N. Shepel
O. M. Drapkina
P. G. Osipov
K. G. Plaksina
N. V. Malay
SCANNING TRANSMISSION ELECTRON MICROSCOPY FOR QUANTITATIVE MAPPING OF MACROELEMENT CONTENTS OF CARDIAC TISSUE
Российский кардиологический журнал
x-ray fluorescent analysis
macroelements
microelements
myocardium
mapping
title SCANNING TRANSMISSION ELECTRON MICROSCOPY FOR QUANTITATIVE MAPPING OF MACROELEMENT CONTENTS OF CARDIAC TISSUE
title_full SCANNING TRANSMISSION ELECTRON MICROSCOPY FOR QUANTITATIVE MAPPING OF MACROELEMENT CONTENTS OF CARDIAC TISSUE
title_fullStr SCANNING TRANSMISSION ELECTRON MICROSCOPY FOR QUANTITATIVE MAPPING OF MACROELEMENT CONTENTS OF CARDIAC TISSUE
title_full_unstemmed SCANNING TRANSMISSION ELECTRON MICROSCOPY FOR QUANTITATIVE MAPPING OF MACROELEMENT CONTENTS OF CARDIAC TISSUE
title_short SCANNING TRANSMISSION ELECTRON MICROSCOPY FOR QUANTITATIVE MAPPING OF MACROELEMENT CONTENTS OF CARDIAC TISSUE
title_sort scanning transmission electron microscopy for quantitative mapping of macroelement contents of cardiac tissue
topic x-ray fluorescent analysis
macroelements
microelements
myocardium
mapping
url https://russjcardiol.elpub.ru/jour/article/view/724
work_keys_str_mv AT aakomisov scanningtransmissionelectronmicroscopyforquantitativemappingofmacroelementcontentsofcardiactissue
AT oaosipova scanningtransmissionelectronmicroscopyforquantitativemappingofmacroelementcontentsofcardiactissue
AT rnshepel scanningtransmissionelectronmicroscopyforquantitativemappingofmacroelementcontentsofcardiactissue
AT omdrapkina scanningtransmissionelectronmicroscopyforquantitativemappingofmacroelementcontentsofcardiactissue
AT pgosipov scanningtransmissionelectronmicroscopyforquantitativemappingofmacroelementcontentsofcardiactissue
AT kgplaksina scanningtransmissionelectronmicroscopyforquantitativemappingofmacroelementcontentsofcardiactissue
AT nvmalay scanningtransmissionelectronmicroscopyforquantitativemappingofmacroelementcontentsofcardiactissue