Effect of Walking Modes and Temperatures on the Robustness of Ventilation Systems in the Control of Walking-induced Disturbances

Abstract Ventilation system’s effectiveness can be affected by walking-induced disturbances. A series of experiments were performed in a chamber in this study considering the following parameter variations: four types of ventilation systems (i.e., ceiling supply and side return, ceiling supply and c...

Full description

Saved in:
Bibliographic Details
Main Authors: Jianlin Ren, Junjie He, Leihong Guo, Hongwan Li, Xiangfei Kong
Format: Article
Language:English
Published: Springer 2022-06-01
Series:Aerosol and Air Quality Research
Subjects:
Online Access:https://doi.org/10.4209/aaqr.220115
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1825197635866198016
author Jianlin Ren
Junjie He
Leihong Guo
Hongwan Li
Xiangfei Kong
author_facet Jianlin Ren
Junjie He
Leihong Guo
Hongwan Li
Xiangfei Kong
author_sort Jianlin Ren
collection DOAJ
description Abstract Ventilation system’s effectiveness can be affected by walking-induced disturbances. A series of experiments were performed in a chamber in this study considering the following parameter variations: four types of ventilation systems (i.e., ceiling supply and side return, ceiling supply and ceiling return, side supply and ceiling return, side supply and side return), three temperature levels (18°C, 23°C, 28°C), and three walking modes (W1, W2, W3). The test results showed that the cumulative particle exposure levels under walking modes W1, W2 and W3 were 2.04 ± 0.27, 1.72 ± 0.26 and 0.87 ± 0.12 times the exposure levels without human walking. The four ventilation systems can maintain a high stability of the indoor temperature field; however, different walking modes and ventilation systems would result in different walking-induced disturbances of the pollutant and flow fields. For the flow field, the range scale robustness (RSr) value with ventilation system was 4.0%–18.2% higher than that without ventilation system. The highest RSr value was achieved by the side supply and side return (SS) system. For the pollutant field, the RSr and time scale robustness (TSr) can be increased by 23.0%–44.0% and 11.5%–23.3% due to the ventilation systems, respectively. The RSr value of the SS system was still the largest, 18.7% larger than the smallest value. With the increase in temperature from 18°C to 28°C, the RSr and TSr of the different ventilation systems decreased by 7.7%–18.4% and 1.3%–15.7%, respectively. A ventilation system with high particle-removal efficiency may not be effective in controlling indoor disturbances. The database and method developed in this study could be beneficial for the control of human walking-induced disturbances in those settings that require a highly controlled indoor environment.
format Article
id doaj-art-8562a4e57a634aaf9cea693c7944ba8c
institution Kabale University
issn 1680-8584
2071-1409
language English
publishDate 2022-06-01
publisher Springer
record_format Article
series Aerosol and Air Quality Research
spelling doaj-art-8562a4e57a634aaf9cea693c7944ba8c2025-02-09T12:17:36ZengSpringerAerosol and Air Quality Research1680-85842071-14092022-06-0122711710.4209/aaqr.220115Effect of Walking Modes and Temperatures on the Robustness of Ventilation Systems in the Control of Walking-induced DisturbancesJianlin Ren0Junjie He1Leihong Guo2Hongwan Li3Xiangfei Kong4School of Energy and Environmental Engineering, Hebei University of TechnologySchool of Energy and Environmental Engineering, Hebei University of TechnologyTianjin Jin’an Thermal Power Co., Ltd.Department of Environmental Engineering Sciences, University of FloridaSchool of Energy and Environmental Engineering, Hebei University of TechnologyAbstract Ventilation system’s effectiveness can be affected by walking-induced disturbances. A series of experiments were performed in a chamber in this study considering the following parameter variations: four types of ventilation systems (i.e., ceiling supply and side return, ceiling supply and ceiling return, side supply and ceiling return, side supply and side return), three temperature levels (18°C, 23°C, 28°C), and three walking modes (W1, W2, W3). The test results showed that the cumulative particle exposure levels under walking modes W1, W2 and W3 were 2.04 ± 0.27, 1.72 ± 0.26 and 0.87 ± 0.12 times the exposure levels without human walking. The four ventilation systems can maintain a high stability of the indoor temperature field; however, different walking modes and ventilation systems would result in different walking-induced disturbances of the pollutant and flow fields. For the flow field, the range scale robustness (RSr) value with ventilation system was 4.0%–18.2% higher than that without ventilation system. The highest RSr value was achieved by the side supply and side return (SS) system. For the pollutant field, the RSr and time scale robustness (TSr) can be increased by 23.0%–44.0% and 11.5%–23.3% due to the ventilation systems, respectively. The RSr value of the SS system was still the largest, 18.7% larger than the smallest value. With the increase in temperature from 18°C to 28°C, the RSr and TSr of the different ventilation systems decreased by 7.7%–18.4% and 1.3%–15.7%, respectively. A ventilation system with high particle-removal efficiency may not be effective in controlling indoor disturbances. The database and method developed in this study could be beneficial for the control of human walking-induced disturbances in those settings that require a highly controlled indoor environment.https://doi.org/10.4209/aaqr.220115DenoisingGaussian fittingRobustnessVentilation systemParticle control
spellingShingle Jianlin Ren
Junjie He
Leihong Guo
Hongwan Li
Xiangfei Kong
Effect of Walking Modes and Temperatures on the Robustness of Ventilation Systems in the Control of Walking-induced Disturbances
Aerosol and Air Quality Research
Denoising
Gaussian fitting
Robustness
Ventilation system
Particle control
title Effect of Walking Modes and Temperatures on the Robustness of Ventilation Systems in the Control of Walking-induced Disturbances
title_full Effect of Walking Modes and Temperatures on the Robustness of Ventilation Systems in the Control of Walking-induced Disturbances
title_fullStr Effect of Walking Modes and Temperatures on the Robustness of Ventilation Systems in the Control of Walking-induced Disturbances
title_full_unstemmed Effect of Walking Modes and Temperatures on the Robustness of Ventilation Systems in the Control of Walking-induced Disturbances
title_short Effect of Walking Modes and Temperatures on the Robustness of Ventilation Systems in the Control of Walking-induced Disturbances
title_sort effect of walking modes and temperatures on the robustness of ventilation systems in the control of walking induced disturbances
topic Denoising
Gaussian fitting
Robustness
Ventilation system
Particle control
url https://doi.org/10.4209/aaqr.220115
work_keys_str_mv AT jianlinren effectofwalkingmodesandtemperaturesontherobustnessofventilationsystemsinthecontrolofwalkinginduceddisturbances
AT junjiehe effectofwalkingmodesandtemperaturesontherobustnessofventilationsystemsinthecontrolofwalkinginduceddisturbances
AT leihongguo effectofwalkingmodesandtemperaturesontherobustnessofventilationsystemsinthecontrolofwalkinginduceddisturbances
AT hongwanli effectofwalkingmodesandtemperaturesontherobustnessofventilationsystemsinthecontrolofwalkinginduceddisturbances
AT xiangfeikong effectofwalkingmodesandtemperaturesontherobustnessofventilationsystemsinthecontrolofwalkinginduceddisturbances