Influence of Segment Shape Optimization Parameter in Radiotherapy Volumetric Modulated Arc Therapy Planning of Cervical Cancer
Introduction: The aim of this study is to find out the influence of different Segment shape optimization (SSO) parameters in radiotherapy Volumetric Modulated Arc therapy (VMAT) planning of Cervical Cancer and to find out the optimized value for cervical cancer patients.Material and Methods: It was...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mashhad University of Medical Sciences
2024-07-01
|
Series: | Iranian Journal of Medical Physics |
Subjects: | |
Online Access: | https://ijmp.mums.ac.ir/article_25065_9b27e8f4a5ed797034fd815a1b2d5e20.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832595693056819200 |
---|---|
author | Nidhi Jain Alok Kumar Ashok Kumar |
author_facet | Nidhi Jain Alok Kumar Ashok Kumar |
author_sort | Nidhi Jain |
collection | DOAJ |
description | Introduction: The aim of this study is to find out the influence of different Segment shape optimization (SSO) parameters in radiotherapy Volumetric Modulated Arc therapy (VMAT) planning of Cervical Cancer and to find out the optimized value for cervical cancer patients.Material and Methods: It was a retrospective study of 20 Ca cervix patients. Every patient had six plans named SL1, SL5, SL10, SL15, SL20, and NSL. In each case, the value of the shaping loop will be changed during the VMAT plan, while the other optimization parameters and constraint functions will remain the same in each case. All Dosimetric parameters have been measured and analysed for Planning Target Volume (PTV) and Organ at risk (OAR) dose, Monitor Unit (MU), memory, Plan Delivery Time (PDT), and Gamma Passing Rate (GPR) for comparison purposes.Results: In NSL cases, the PTV dose derived from the DVH did not meet the clinical standards D95% = 86.8% (<95%) with a poorer homogeneity index (HI = 0.2). As the SL value increases, plan quality increases, monitor units increase slightly and plan delivery time decreases while there is a parallel increase in memory consumption. There is no statistical difference in target dose and OAR dose between the SL5 and SL1 plans (P > 0.05) compared with the other groups. SL5 has the least plan memory compared to other SL values.Conclusion: Based on the plan quality, the dose accuracy, and the efficiency of delivery, SL1 and SL5 have similar characteristics in cervical cancer cases. Both SL1 and SL5 values should recommend for cervical cancer VMAT planning. |
format | Article |
id | doaj-art-85168ce722cd496fb910d3135d2c3f63 |
institution | Kabale University |
issn | 2345-3672 |
language | English |
publishDate | 2024-07-01 |
publisher | Mashhad University of Medical Sciences |
record_format | Article |
series | Iranian Journal of Medical Physics |
spelling | doaj-art-85168ce722cd496fb910d3135d2c3f632025-01-18T07:32:32ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722024-07-0121425826410.22038/ijmp.2023.69271.222025065Influence of Segment Shape Optimization Parameter in Radiotherapy Volumetric Modulated Arc Therapy Planning of Cervical CancerNidhi Jain0Alok Kumar1Ashok Kumar2Department of Physics, AIAS, Amity University, U.P., IndiaDepartment of Radiation Oncology, Netaji Subhas Chandra Bose Cancer Hospital and Institute, Kolkata, West Bengal, IndiaDepartment of Physics, AIAS, Amity University, U.P., IndiaIntroduction: The aim of this study is to find out the influence of different Segment shape optimization (SSO) parameters in radiotherapy Volumetric Modulated Arc therapy (VMAT) planning of Cervical Cancer and to find out the optimized value for cervical cancer patients.Material and Methods: It was a retrospective study of 20 Ca cervix patients. Every patient had six plans named SL1, SL5, SL10, SL15, SL20, and NSL. In each case, the value of the shaping loop will be changed during the VMAT plan, while the other optimization parameters and constraint functions will remain the same in each case. All Dosimetric parameters have been measured and analysed for Planning Target Volume (PTV) and Organ at risk (OAR) dose, Monitor Unit (MU), memory, Plan Delivery Time (PDT), and Gamma Passing Rate (GPR) for comparison purposes.Results: In NSL cases, the PTV dose derived from the DVH did not meet the clinical standards D95% = 86.8% (<95%) with a poorer homogeneity index (HI = 0.2). As the SL value increases, plan quality increases, monitor units increase slightly and plan delivery time decreases while there is a parallel increase in memory consumption. There is no statistical difference in target dose and OAR dose between the SL5 and SL1 plans (P > 0.05) compared with the other groups. SL5 has the least plan memory compared to other SL values.Conclusion: Based on the plan quality, the dose accuracy, and the efficiency of delivery, SL1 and SL5 have similar characteristics in cervical cancer cases. Both SL1 and SL5 values should recommend for cervical cancer VMAT planning.https://ijmp.mums.ac.ir/article_25065_9b27e8f4a5ed797034fd815a1b2d5e20.pdfcervical cancervmatsequencing parametervolumetric modulated arc therapy |
spellingShingle | Nidhi Jain Alok Kumar Ashok Kumar Influence of Segment Shape Optimization Parameter in Radiotherapy Volumetric Modulated Arc Therapy Planning of Cervical Cancer Iranian Journal of Medical Physics cervical cancer vmat sequencing parameter volumetric modulated arc therapy |
title | Influence of Segment Shape Optimization Parameter in Radiotherapy Volumetric Modulated Arc Therapy Planning of Cervical Cancer |
title_full | Influence of Segment Shape Optimization Parameter in Radiotherapy Volumetric Modulated Arc Therapy Planning of Cervical Cancer |
title_fullStr | Influence of Segment Shape Optimization Parameter in Radiotherapy Volumetric Modulated Arc Therapy Planning of Cervical Cancer |
title_full_unstemmed | Influence of Segment Shape Optimization Parameter in Radiotherapy Volumetric Modulated Arc Therapy Planning of Cervical Cancer |
title_short | Influence of Segment Shape Optimization Parameter in Radiotherapy Volumetric Modulated Arc Therapy Planning of Cervical Cancer |
title_sort | influence of segment shape optimization parameter in radiotherapy volumetric modulated arc therapy planning of cervical cancer |
topic | cervical cancer vmat sequencing parameter volumetric modulated arc therapy |
url | https://ijmp.mums.ac.ir/article_25065_9b27e8f4a5ed797034fd815a1b2d5e20.pdf |
work_keys_str_mv | AT nidhijain influenceofsegmentshapeoptimizationparameterinradiotherapyvolumetricmodulatedarctherapyplanningofcervicalcancer AT alokkumar influenceofsegmentshapeoptimizationparameterinradiotherapyvolumetricmodulatedarctherapyplanningofcervicalcancer AT ashokkumar influenceofsegmentshapeoptimizationparameterinradiotherapyvolumetricmodulatedarctherapyplanningofcervicalcancer |