Early evaluation of the aortic root after Nicks' procedureCentral MessagePerspective

Objective(s): To determine the influence of surgical techniques adopted to avoid suture line disruption, periprosthetic leakage, patch dislodgement, pericardial patch aneurysm formation, and the long-term stability of aortic root enlargement (ARE) during aortic valve replacement (AVR). Methods: One...

Full description

Saved in:
Bibliographic Details
Main Authors: Ujjwal Kumar Chowdhury, MCh, Diplomate NB, Sukhjeet Singh, MCh, Niwin George, MCh, Suruchi Hasija, DM, Lakshmikumari Sankhyan, MCh, Niraj Nirmal Pandey, DM, Sanjoy Sengupta, Diplomate, MCh, Mani Kalaivani, PhD
Format: Article
Language:English
Published: Elsevier 2020-12-01
Series:JTCVS Techniques
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666250720303928
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective(s): To determine the influence of surgical techniques adopted to avoid suture line disruption, periprosthetic leakage, patch dislodgement, pericardial patch aneurysm formation, and the long-term stability of aortic root enlargement (ARE) during aortic valve replacement (AVR). Methods: One hundred fifteen patients undergoing AVR or combined aortic and mitral valve replacements with Nicks' posterior ARE between 1997 and 2019 underwent long-term echocardiographic and angio-computed tomographic evaluation. Age was 11-72 years (AVR: median, 30; interquartile range, 21-47 years; AVR and mitral valve replacement: median, 27.5; interquartile range, 20-37.5 years). The aortotomy was closed using autologous pericardial patch and Teflon-buttressed sutures. Results: Hospital mortality was 1.7% (n = 2), with 4 (3.5%) late deaths. At a mean follow-up of 123.11 ± 77.67 months, the survival probability from Kaplan–Meier was 93.25 ± 0.03%. No cases of severe prosthesis–patient mismatch (PPM) were observed, and only 2 patients had moderate PPM. Median aortic root diameters at the level of sinus of Valsalva and sinotubular junction were 32 (29-35) mm and 33 (30-36) mm, respectively, at discharge, and were 33 (30-36) mm, and 33 (31-37) mm, respectively, at latest follow-up, with no cases of late pericardial patch aneurysm. Conclusions: ARE is a safe adjunct to AVR in patients with a small aortic annulus to prevent PPM. Retention of a pericardial collar and Teflon-buttressed sutures is an expedient, safe, and effective technique in reducing bleeding at the enlarged ventriculo-aortic junction. Autologous pericardial patch aortoplasty is not associated with late aneurysm/pseudoaneurysm formation.
ISSN:2666-2507