Structural and hemodynamic analysis of Weaire-Phelan scaffolds made of Ti-alloy as bone replacement component: A preclinical investigation.

In recent years, additively manufactured metallic scaffolds have generated significant interest among researchers working in the field of bone tissue engineering and orthopaedic implants. Although such intricate, porous architectures are promising as bone substitutes, they need to be thoroughly test...

Full description

Saved in:
Bibliographic Details
Main Authors: Jaideep Singh Bhardwaj, Souptick Chanda
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2024-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0312880
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850245998808399872
author Jaideep Singh Bhardwaj
Souptick Chanda
author_facet Jaideep Singh Bhardwaj
Souptick Chanda
author_sort Jaideep Singh Bhardwaj
collection DOAJ
description In recent years, additively manufactured metallic scaffolds have generated significant interest among researchers working in the field of bone tissue engineering and orthopaedic implants. Although such intricate, porous architectures are promising as bone substitutes, they need to be thoroughly tested for structural robustness as well as their capacity for bony integration. In this present work, we introduced and preclinically evaluated the biomechanical viability of Weaire-Phelan (WP) Ti-alloy scaffolds as bone replacement components. Two distinct groups of WP scaffolds, namely WPA and WPD, of varying porosities were examined for comparative assessment. Finite element (FE) analysis, computational fluid dynamics (CFD) and uniaxial compression tests were performed on 3D printed as-built scaffolds to comprehensively evaluate the structural, hemodynamic, fatigue and morphometric properties of the two groups. The mechanical performances of the WP scaffolds of 70%, 80% 90% porous group (relative density 0.3 and lower) were found to accord with the natural trabecular bone tissue. However, WPA scaffolds demonstrated slightly superior mechanical performances as compared to WPD scaffolds (22%- 63% greater compressive modulus depending on the porosity). On the other hand, WPD scaffolds showed improved hemodynamic properties thereby implying enhanced osteogenic potential. Moreover, the range of effective elastic moduli corresponding to the WP scaffolds was found to be in good agreement with that of the natural bone tissue. As such, these designs were categorized based on their suitability at different anatomical sites. The overall performance metrics of the WP scaffolds underscore its potential for improved osseointegration, structural conformities and greater capacity for customization with enhanced manufacturability.
format Article
id doaj-art-8421c01e35014bf294e314b874dbd5cf
institution OA Journals
issn 1932-6203
language English
publishDate 2024-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj-art-8421c01e35014bf294e314b874dbd5cf2025-08-20T01:59:17ZengPublic Library of Science (PLoS)PLoS ONE1932-62032024-01-011912e031288010.1371/journal.pone.0312880Structural and hemodynamic analysis of Weaire-Phelan scaffolds made of Ti-alloy as bone replacement component: A preclinical investigation.Jaideep Singh BhardwajSouptick ChandaIn recent years, additively manufactured metallic scaffolds have generated significant interest among researchers working in the field of bone tissue engineering and orthopaedic implants. Although such intricate, porous architectures are promising as bone substitutes, they need to be thoroughly tested for structural robustness as well as their capacity for bony integration. In this present work, we introduced and preclinically evaluated the biomechanical viability of Weaire-Phelan (WP) Ti-alloy scaffolds as bone replacement components. Two distinct groups of WP scaffolds, namely WPA and WPD, of varying porosities were examined for comparative assessment. Finite element (FE) analysis, computational fluid dynamics (CFD) and uniaxial compression tests were performed on 3D printed as-built scaffolds to comprehensively evaluate the structural, hemodynamic, fatigue and morphometric properties of the two groups. The mechanical performances of the WP scaffolds of 70%, 80% 90% porous group (relative density 0.3 and lower) were found to accord with the natural trabecular bone tissue. However, WPA scaffolds demonstrated slightly superior mechanical performances as compared to WPD scaffolds (22%- 63% greater compressive modulus depending on the porosity). On the other hand, WPD scaffolds showed improved hemodynamic properties thereby implying enhanced osteogenic potential. Moreover, the range of effective elastic moduli corresponding to the WP scaffolds was found to be in good agreement with that of the natural bone tissue. As such, these designs were categorized based on their suitability at different anatomical sites. The overall performance metrics of the WP scaffolds underscore its potential for improved osseointegration, structural conformities and greater capacity for customization with enhanced manufacturability.https://doi.org/10.1371/journal.pone.0312880
spellingShingle Jaideep Singh Bhardwaj
Souptick Chanda
Structural and hemodynamic analysis of Weaire-Phelan scaffolds made of Ti-alloy as bone replacement component: A preclinical investigation.
PLoS ONE
title Structural and hemodynamic analysis of Weaire-Phelan scaffolds made of Ti-alloy as bone replacement component: A preclinical investigation.
title_full Structural and hemodynamic analysis of Weaire-Phelan scaffolds made of Ti-alloy as bone replacement component: A preclinical investigation.
title_fullStr Structural and hemodynamic analysis of Weaire-Phelan scaffolds made of Ti-alloy as bone replacement component: A preclinical investigation.
title_full_unstemmed Structural and hemodynamic analysis of Weaire-Phelan scaffolds made of Ti-alloy as bone replacement component: A preclinical investigation.
title_short Structural and hemodynamic analysis of Weaire-Phelan scaffolds made of Ti-alloy as bone replacement component: A preclinical investigation.
title_sort structural and hemodynamic analysis of weaire phelan scaffolds made of ti alloy as bone replacement component a preclinical investigation
url https://doi.org/10.1371/journal.pone.0312880
work_keys_str_mv AT jaideepsinghbhardwaj structuralandhemodynamicanalysisofweairephelanscaffoldsmadeoftialloyasbonereplacementcomponentapreclinicalinvestigation
AT souptickchanda structuralandhemodynamicanalysisofweairephelanscaffoldsmadeoftialloyasbonereplacementcomponentapreclinicalinvestigation