HPLC method with monolithic column for simultaneous determination of irbesartan and hydrochlorothiazide in tablets

A simple, sensitive and accurate HPLC method with high throughput has been developed and validated for the simultaneous determination of irbesartan (IRB) and hydrochlorothiazide (HCT) in combined pharmaceutical dosage forms. The proposed method employed, for the first time, a monolithic column in th...

Full description

Saved in:
Bibliographic Details
Main Authors: Alanazi Amer M., Abdelhameed Ali S., Khalil Nasr Y., Khan Azmat A., Darwish Ibrahim A.
Format: Article
Language:English
Published: Sciendo 2014-06-01
Series:Acta Pharmaceutica
Subjects:
Online Access:http://www.degruyter.com/view/j/acph.2014.64.issue-2/acph-2014-0014/acph-2014-0014.xml?format=INT
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832574303626854400
author Alanazi Amer M.
Abdelhameed Ali S.
Khalil Nasr Y.
Khan Azmat A.
Darwish Ibrahim A.
author_facet Alanazi Amer M.
Abdelhameed Ali S.
Khalil Nasr Y.
Khan Azmat A.
Darwish Ibrahim A.
author_sort Alanazi Amer M.
collection DOAJ
description A simple, sensitive and accurate HPLC method with high throughput has been developed and validated for the simultaneous determination of irbesartan (IRB) and hydrochlorothiazide (HCT) in combined pharmaceutical dosage forms. The proposed method employed, for the first time, a monolithic column in the analysis. Optimal chromatographic separation of the analytes was achieved on Chromolith® Performance RP-18e column using a mobile phase consisting of phosphate buffer (pH 4)/acetonitrile (50:50, V/V) pumped isocratically at a flow rate of 1.0 mL min-1. The eluted analytes were monitored with a UV detector set at 270 nm. Under the optimum chromatographic conditions, linear relationship with a good correlation coefficient (R ≥ 0.9997) was found between the peak area and the corresponding concentrations of both IRB and HCT in the ranges of 10-200 and 1-20 ng mL-1. The limits of detection were 2.34 and 0.03 ng mL-1 for IRB and HCT, respectively. The intra- and inter-assay precisions were satisfactory as the RSD values did not exceed 3 %. The accuracy of the proposed method was > 97 %. The proposed method had high throughput as the analysis involved a simple procedure and a very short run- -time of < 3 min. The results demonstrated that the method is applicable in the quality control of combined pharmaceutical tablets containing IRB and HCT
format Article
id doaj-art-83d0371cb9314b97bbfb392995cf552b
institution Kabale University
issn 1330-0075
1846-9558
language English
publishDate 2014-06-01
publisher Sciendo
record_format Article
series Acta Pharmaceutica
spelling doaj-art-83d0371cb9314b97bbfb392995cf552b2025-02-02T00:04:16ZengSciendoActa Pharmaceutica1330-00751846-95582014-06-0164218719810.2478/acph-2014-0014acph-2014-0014HPLC method with monolithic column for simultaneous determination of irbesartan and hydrochlorothiazide in tabletsAlanazi Amer M.0Abdelhameed Ali S.1Khalil Nasr Y.2Khan Azmat A.3Darwish Ibrahim A.4Department of Pharmaceutical Chemistry College of Pharmacy, King Saud University P.O. Box 2457 Riyadh, 11451 Kingdom of Saudi ArabiaDepartment of Pharmaceutical Chemistry College of Pharmacy, King Saud University P.O. Box 2457 Riyadh, 11451 Kingdom of Saudi ArabiaDepartment of Pharmaceutical Chemistry College of Pharmacy, King Saud University P.O. Box 2457 Riyadh, 11451 Kingdom of Saudi ArabiaDepartment of Pharmaceutical Chemistry College of Pharmacy, King Saud University P.O. Box 2457 Riyadh, 11451 Kingdom of Saudi ArabiaDepartment of Pharmaceutical Chemistry College of Pharmacy, King Saud University P.O. Box 2457 Riyadh, 11451 Kingdom of Saudi ArabiaA simple, sensitive and accurate HPLC method with high throughput has been developed and validated for the simultaneous determination of irbesartan (IRB) and hydrochlorothiazide (HCT) in combined pharmaceutical dosage forms. The proposed method employed, for the first time, a monolithic column in the analysis. Optimal chromatographic separation of the analytes was achieved on Chromolith® Performance RP-18e column using a mobile phase consisting of phosphate buffer (pH 4)/acetonitrile (50:50, V/V) pumped isocratically at a flow rate of 1.0 mL min-1. The eluted analytes were monitored with a UV detector set at 270 nm. Under the optimum chromatographic conditions, linear relationship with a good correlation coefficient (R ≥ 0.9997) was found between the peak area and the corresponding concentrations of both IRB and HCT in the ranges of 10-200 and 1-20 ng mL-1. The limits of detection were 2.34 and 0.03 ng mL-1 for IRB and HCT, respectively. The intra- and inter-assay precisions were satisfactory as the RSD values did not exceed 3 %. The accuracy of the proposed method was > 97 %. The proposed method had high throughput as the analysis involved a simple procedure and a very short run- -time of < 3 min. The results demonstrated that the method is applicable in the quality control of combined pharmaceutical tablets containing IRB and HCThttp://www.degruyter.com/view/j/acph.2014.64.issue-2/acph-2014-0014/acph-2014-0014.xml?format=INTirbesartanhydrochlorothiazideHPLC-UVmonolithic column
spellingShingle Alanazi Amer M.
Abdelhameed Ali S.
Khalil Nasr Y.
Khan Azmat A.
Darwish Ibrahim A.
HPLC method with monolithic column for simultaneous determination of irbesartan and hydrochlorothiazide in tablets
Acta Pharmaceutica
irbesartan
hydrochlorothiazide
HPLC-UV
monolithic column
title HPLC method with monolithic column for simultaneous determination of irbesartan and hydrochlorothiazide in tablets
title_full HPLC method with monolithic column for simultaneous determination of irbesartan and hydrochlorothiazide in tablets
title_fullStr HPLC method with monolithic column for simultaneous determination of irbesartan and hydrochlorothiazide in tablets
title_full_unstemmed HPLC method with monolithic column for simultaneous determination of irbesartan and hydrochlorothiazide in tablets
title_short HPLC method with monolithic column for simultaneous determination of irbesartan and hydrochlorothiazide in tablets
title_sort hplc method with monolithic column for simultaneous determination of irbesartan and hydrochlorothiazide in tablets
topic irbesartan
hydrochlorothiazide
HPLC-UV
monolithic column
url http://www.degruyter.com/view/j/acph.2014.64.issue-2/acph-2014-0014/acph-2014-0014.xml?format=INT
work_keys_str_mv AT alanaziamerm hplcmethodwithmonolithiccolumnforsimultaneousdeterminationofirbesartanandhydrochlorothiazideintablets
AT abdelhameedalis hplcmethodwithmonolithiccolumnforsimultaneousdeterminationofirbesartanandhydrochlorothiazideintablets
AT khalilnasry hplcmethodwithmonolithiccolumnforsimultaneousdeterminationofirbesartanandhydrochlorothiazideintablets
AT khanazmata hplcmethodwithmonolithiccolumnforsimultaneousdeterminationofirbesartanandhydrochlorothiazideintablets
AT darwishibrahima hplcmethodwithmonolithiccolumnforsimultaneousdeterminationofirbesartanandhydrochlorothiazideintablets