Estimation of the collateral circulation index (CCI) in the lower extremities using the impedance rheography and ultrasonic methods

In this study values of volumetric blood flow in the thigh, measured using the impedance rheography, were compared with values of volumetric flow in the common femoral artery, measured using the ultrasonic method. We examinated 32 healthy and 46 sick people with occlusion of the pelvic limb arteries...

Full description

Saved in:
Bibliographic Details
Main Authors: Jerzy WESOŁOWSKI, Andrzej NOWICKI, Barbara TOPOLSKA, Grzegorz PAWLICKI, Leszek FILIPCZYŃSKI, Tadeusz PAŁKO, Henryk RYKOWSKI
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2015-07-01
Series:Archives of Acoustics
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/3212
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850104469086273536
author Jerzy WESOŁOWSKI
Andrzej NOWICKI
Barbara TOPOLSKA
Grzegorz PAWLICKI
Leszek FILIPCZYŃSKI
Tadeusz PAŁKO
Henryk RYKOWSKI
author_facet Jerzy WESOŁOWSKI
Andrzej NOWICKI
Barbara TOPOLSKA
Grzegorz PAWLICKI
Leszek FILIPCZYŃSKI
Tadeusz PAŁKO
Henryk RYKOWSKI
author_sort Jerzy WESOŁOWSKI
collection DOAJ
description In this study values of volumetric blood flow in the thigh, measured using the impedance rheography, were compared with values of volumetric flow in the common femoral artery, measured using the ultrasonic method. We examinated 32 healthy and 46 sick people with occlusion of the pelvic limb arteries. More than 120 measurements were made on these subjects. We ascertained diagnostic usefulness of both methods to simultaneous measurement of blood flow in the peripheral vessels. It seems that association of both of the methods — rheographic and ultrasonic — permits the collateral blood flow to be calculated.
format Article
id doaj-art-820eed04b6594be2bc2b2c268e5fc098
institution DOAJ
issn 0137-5075
2300-262X
language English
publishDate 2015-07-01
publisher Institute of Fundamental Technological Research Polish Academy of Sciences
record_format Article
series Archives of Acoustics
spelling doaj-art-820eed04b6594be2bc2b2c268e5fc0982025-08-20T02:39:19ZengInstitute of Fundamental Technological Research Polish Academy of SciencesArchives of Acoustics0137-50752300-262X2015-07-0191-2Estimation of the collateral circulation index (CCI) in the lower extremities using the impedance rheography and ultrasonic methodsJerzy WESOŁOWSKI0Andrzej NOWICKI1Barbara TOPOLSKA2Grzegorz PAWLICKI3Leszek FILIPCZYŃSKI4Tadeusz PAŁKO5Henryk RYKOWSKI6Clinic of Vessel Surgery, Medical Center of Postgraduate EducationInstitute of Fundamental Technological Research, Polish Academy of SciencesInstitute of Fundamental Technological Research, Polish Academy of SciencesInstitute of Fundamental Technological Research, Polish Academy of SciencesInstitute of Fundamental Technological Research, Polish Academy of SciencesInstitute of Precision and Biomedical Engineering, Technical University of WarsawInstitute of Precision and Biomedical Engineering, Technical University of WarsawIn this study values of volumetric blood flow in the thigh, measured using the impedance rheography, were compared with values of volumetric flow in the common femoral artery, measured using the ultrasonic method. We examinated 32 healthy and 46 sick people with occlusion of the pelvic limb arteries. More than 120 measurements were made on these subjects. We ascertained diagnostic usefulness of both methods to simultaneous measurement of blood flow in the peripheral vessels. It seems that association of both of the methods — rheographic and ultrasonic — permits the collateral blood flow to be calculated.https://acoustics.ippt.pan.pl/index.php/aa/article/view/3212
spellingShingle Jerzy WESOŁOWSKI
Andrzej NOWICKI
Barbara TOPOLSKA
Grzegorz PAWLICKI
Leszek FILIPCZYŃSKI
Tadeusz PAŁKO
Henryk RYKOWSKI
Estimation of the collateral circulation index (CCI) in the lower extremities using the impedance rheography and ultrasonic methods
Archives of Acoustics
title Estimation of the collateral circulation index (CCI) in the lower extremities using the impedance rheography and ultrasonic methods
title_full Estimation of the collateral circulation index (CCI) in the lower extremities using the impedance rheography and ultrasonic methods
title_fullStr Estimation of the collateral circulation index (CCI) in the lower extremities using the impedance rheography and ultrasonic methods
title_full_unstemmed Estimation of the collateral circulation index (CCI) in the lower extremities using the impedance rheography and ultrasonic methods
title_short Estimation of the collateral circulation index (CCI) in the lower extremities using the impedance rheography and ultrasonic methods
title_sort estimation of the collateral circulation index cci in the lower extremities using the impedance rheography and ultrasonic methods
url https://acoustics.ippt.pan.pl/index.php/aa/article/view/3212
work_keys_str_mv AT jerzywesołowski estimationofthecollateralcirculationindexcciinthelowerextremitiesusingtheimpedancerheographyandultrasonicmethods
AT andrzejnowicki estimationofthecollateralcirculationindexcciinthelowerextremitiesusingtheimpedancerheographyandultrasonicmethods
AT barbaratopolska estimationofthecollateralcirculationindexcciinthelowerextremitiesusingtheimpedancerheographyandultrasonicmethods
AT grzegorzpawlicki estimationofthecollateralcirculationindexcciinthelowerextremitiesusingtheimpedancerheographyandultrasonicmethods
AT leszekfilipczynski estimationofthecollateralcirculationindexcciinthelowerextremitiesusingtheimpedancerheographyandultrasonicmethods
AT tadeuszpałko estimationofthecollateralcirculationindexcciinthelowerextremitiesusingtheimpedancerheographyandultrasonicmethods
AT henrykrykowski estimationofthecollateralcirculationindexcciinthelowerextremitiesusingtheimpedancerheographyandultrasonicmethods