The radiation sterilization technique applied to the powder of Nelumbo nucifera
Using <sup>60</sup>Coy-ray irradiation sterilizat technique for ion powder of Nelumbo nucifera was studied. The appropriate irradiation dose for sterilization was 6 kGy. The results demonstrated that the microorganism in the products can be sterilized efficiently with γ-ray irradiation....
Saved in:
| Main Author: | |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Zhejiang University Press
2000-09-01
|
| Series: | 浙江大学学报. 农业与生命科学版 |
| Subjects: | |
| Online Access: | https://www.academax.com/doi/10.3785/1008-9209.2000.05.0537 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850044670172725248 |
|---|---|
| author | SHEN Wei-qiao |
| author_facet | SHEN Wei-qiao |
| author_sort | SHEN Wei-qiao |
| collection | DOAJ |
| description | Using <sup>60</sup>Coy-ray irradiation sterilizat technique for ion powder of Nelumbo nucifera was studied. The appropriate irradiation dose for sterilization was 6 kGy. The results demonstrated that the microorganism in the products can be sterilized efficiently with γ-ray irradiation. There was no significant differences in the quality of the product before and after γ-radiation, however, the viscosity of starch decreased with the increase of the irradiation dose. |
| format | Article |
| id | doaj-art-81d8f15c951e427c81afd8cd9ee16e7d |
| institution | DOAJ |
| issn | 1008-9209 2097-5155 |
| language | English |
| publishDate | 2000-09-01 |
| publisher | Zhejiang University Press |
| record_format | Article |
| series | 浙江大学学报. 农业与生命科学版 |
| spelling | doaj-art-81d8f15c951e427c81afd8cd9ee16e7d2025-08-20T02:54:53ZengZhejiang University Press浙江大学学报. 农业与生命科学版1008-92092097-51552000-09-012653753910.3785/1008-9209.2000.05.053710089209The radiation sterilization technique applied to the powder of Nelumbo nuciferaSHEN Wei-qiaoUsing <sup>60</sup>Coy-ray irradiation sterilizat technique for ion powder of Nelumbo nucifera was studied. The appropriate irradiation dose for sterilization was 6 kGy. The results demonstrated that the microorganism in the products can be sterilized efficiently with γ-ray irradiation. There was no significant differences in the quality of the product before and after γ-radiation, however, the viscosity of starch decreased with the increase of the irradiation dose.https://www.academax.com/doi/10.3785/1008-9209.2000.05.0537powder of lotus (<italic>Nelumbo nucifera</italic> L.)γ-irradiationsterilizationmicroorganism |
| spellingShingle | SHEN Wei-qiao The radiation sterilization technique applied to the powder of Nelumbo nucifera 浙江大学学报. 农业与生命科学版 powder of lotus (<italic>Nelumbo nucifera</italic> L.) γ-irradiation sterilization microorganism |
| title | The radiation sterilization technique applied to the powder of Nelumbo nucifera |
| title_full | The radiation sterilization technique applied to the powder of Nelumbo nucifera |
| title_fullStr | The radiation sterilization technique applied to the powder of Nelumbo nucifera |
| title_full_unstemmed | The radiation sterilization technique applied to the powder of Nelumbo nucifera |
| title_short | The radiation sterilization technique applied to the powder of Nelumbo nucifera |
| title_sort | radiation sterilization technique applied to the powder of nelumbo nucifera |
| topic | powder of lotus (<italic>Nelumbo nucifera</italic> L.) γ-irradiation sterilization microorganism |
| url | https://www.academax.com/doi/10.3785/1008-9209.2000.05.0537 |
| work_keys_str_mv | AT shenweiqiao theradiationsterilizationtechniqueappliedtothepowderofnelumbonucifera AT shenweiqiao radiationsterilizationtechniqueappliedtothepowderofnelumbonucifera |