Accelerated Real-Time Simulations for Testing a Reactive Power Flow Controller in Long-Term Case Studies
This paper presents the development of an accelerated real-time cosimulation and testing platform, especially for long-term simulations of power systems. The platform is planned to be utilized in the development and testing of active network management functions for microgrids and smart grids. Long-...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2020-01-01
|
| Series: | Journal of Electrical and Computer Engineering |
| Online Access: | http://dx.doi.org/10.1155/2020/8265373 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850214589154721792 |
|---|---|
| author | Katja H. Sirviö Mike Mekkanen Kimmo Kauhaniemi Hannu Laaksonen Ari Salo Felipe Castro Davood Babazadeh |
| author_facet | Katja H. Sirviö Mike Mekkanen Kimmo Kauhaniemi Hannu Laaksonen Ari Salo Felipe Castro Davood Babazadeh |
| author_sort | Katja H. Sirviö |
| collection | DOAJ |
| description | This paper presents the development of an accelerated real-time cosimulation and testing platform, especially for long-term simulations of power systems. The platform is planned to be utilized in the development and testing of active network management functions for microgrids and smart grids. Long-term simulations are needed in order to study, for example, the potential weekly, monthly, or yearly usage of distribution-network-connected distributed energy resources for different technical flexibility services. In order to test new algorithms in long-term study cases, real-time simulations or hardware-in-the-loop tests should be accelerated. This paper analyzes the possibilities and challenges of accelerated long-term simulations in studying the potential use of a large-scale wind turbine for reactive power flow control between distribution system operator (DSO) and transmission system operator (TSO) networks. To this end, the reactive power flow control is studied for different voltage levels (HV and MV) in the Sundom Smart Grid in Vaasa, Finland. The control of reactive power flow between HV and MV networks is realized with a reactive power window control algorithm for a 3.6 MW MV-network-connected wind turbine with a full-scale power converter. The behaviour of the reactive power controller during long-term simulations is studied by offline and real-time simulations. Moreover, the real-time simulations are performed with both software-in-the-loop and controller-hardware-in-the-loop. |
| format | Article |
| id | doaj-art-80a43fa016b2405ca2a3420af4c37e8b |
| institution | OA Journals |
| issn | 2090-0147 2090-0155 |
| language | English |
| publishDate | 2020-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | Journal of Electrical and Computer Engineering |
| spelling | doaj-art-80a43fa016b2405ca2a3420af4c37e8b2025-08-20T02:08:50ZengWileyJournal of Electrical and Computer Engineering2090-01472090-01552020-01-01202010.1155/2020/82653738265373Accelerated Real-Time Simulations for Testing a Reactive Power Flow Controller in Long-Term Case StudiesKatja H. Sirviö0Mike Mekkanen1Kimmo Kauhaniemi2Hannu Laaksonen3Ari Salo4Felipe Castro5Davood Babazadeh6School of Technology and Innovations, University of Vaasa, Vaasa 65200, FinlandSchool of Technology and Innovations, University of Vaasa, Vaasa 65200, FinlandSchool of Technology and Innovations, University of Vaasa, Vaasa 65200, FinlandSchool of Technology and Innovations, University of Vaasa, Vaasa 65200, FinlandVaasan Sähköverkko, Vaasa 65100, FinlandEnergy Division, OFFIS e.V., Oldenburg 26121, GermanyEnergy Division, OFFIS e.V., Oldenburg 26121, GermanyThis paper presents the development of an accelerated real-time cosimulation and testing platform, especially for long-term simulations of power systems. The platform is planned to be utilized in the development and testing of active network management functions for microgrids and smart grids. Long-term simulations are needed in order to study, for example, the potential weekly, monthly, or yearly usage of distribution-network-connected distributed energy resources for different technical flexibility services. In order to test new algorithms in long-term study cases, real-time simulations or hardware-in-the-loop tests should be accelerated. This paper analyzes the possibilities and challenges of accelerated long-term simulations in studying the potential use of a large-scale wind turbine for reactive power flow control between distribution system operator (DSO) and transmission system operator (TSO) networks. To this end, the reactive power flow control is studied for different voltage levels (HV and MV) in the Sundom Smart Grid in Vaasa, Finland. The control of reactive power flow between HV and MV networks is realized with a reactive power window control algorithm for a 3.6 MW MV-network-connected wind turbine with a full-scale power converter. The behaviour of the reactive power controller during long-term simulations is studied by offline and real-time simulations. Moreover, the real-time simulations are performed with both software-in-the-loop and controller-hardware-in-the-loop.http://dx.doi.org/10.1155/2020/8265373 |
| spellingShingle | Katja H. Sirviö Mike Mekkanen Kimmo Kauhaniemi Hannu Laaksonen Ari Salo Felipe Castro Davood Babazadeh Accelerated Real-Time Simulations for Testing a Reactive Power Flow Controller in Long-Term Case Studies Journal of Electrical and Computer Engineering |
| title | Accelerated Real-Time Simulations for Testing a Reactive Power Flow Controller in Long-Term Case Studies |
| title_full | Accelerated Real-Time Simulations for Testing a Reactive Power Flow Controller in Long-Term Case Studies |
| title_fullStr | Accelerated Real-Time Simulations for Testing a Reactive Power Flow Controller in Long-Term Case Studies |
| title_full_unstemmed | Accelerated Real-Time Simulations for Testing a Reactive Power Flow Controller in Long-Term Case Studies |
| title_short | Accelerated Real-Time Simulations for Testing a Reactive Power Flow Controller in Long-Term Case Studies |
| title_sort | accelerated real time simulations for testing a reactive power flow controller in long term case studies |
| url | http://dx.doi.org/10.1155/2020/8265373 |
| work_keys_str_mv | AT katjahsirvio acceleratedrealtimesimulationsfortestingareactivepowerflowcontrollerinlongtermcasestudies AT mikemekkanen acceleratedrealtimesimulationsfortestingareactivepowerflowcontrollerinlongtermcasestudies AT kimmokauhaniemi acceleratedrealtimesimulationsfortestingareactivepowerflowcontrollerinlongtermcasestudies AT hannulaaksonen acceleratedrealtimesimulationsfortestingareactivepowerflowcontrollerinlongtermcasestudies AT arisalo acceleratedrealtimesimulationsfortestingareactivepowerflowcontrollerinlongtermcasestudies AT felipecastro acceleratedrealtimesimulationsfortestingareactivepowerflowcontrollerinlongtermcasestudies AT davoodbabazadeh acceleratedrealtimesimulationsfortestingareactivepowerflowcontrollerinlongtermcasestudies |