Transient stability criterion of grid-forming converter based on DC voltage synchronization control considering current limit

In order to address the synchronization stability of grid-forming converters considering current limiting constraints,a switching dynamic model of the system of a single converter connected to the grid based on direct current voltage synchronization control (DVSC) strategy considering current limiti...

Full description

Saved in:
Bibliographic Details
Main Authors: Jingrui LIU, Zengze TU, Yufei ZHANG, Yang ZHANG, Jiapeng LI, Yujun LI
Format: Article
Language:zho
Published: Editorial Department of Electric Power Engineering Technology 2025-03-01
Series:电力工程技术
Subjects:
Online Access:https://doi.org/10.12158/j.2096-3203.2025.02.001
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849704444681256960
author Jingrui LIU
Zengze TU
Yufei ZHANG
Yang ZHANG
Jiapeng LI
Yujun LI
author_facet Jingrui LIU
Zengze TU
Yufei ZHANG
Yang ZHANG
Jiapeng LI
Yujun LI
author_sort Jingrui LIU
collection DOAJ
description In order to address the synchronization stability of grid-forming converters considering current limiting constraints,a switching dynamic model of the system of a single converter connected to the grid based on direct current voltage synchronization control (DVSC) strategy considering current limiting is established in this paper. Grid-forming converters without current limiting constraints will only operate in the constant voltage control mode after fault clearance,while those with current limiting constraints may stabilize in different modes like constant voltage control mode or constant current control mode. Therefore,the transient stability of studied model is analyzed using the segmental equal area criteria (SEAC) in this paper and the analytical expression of the critical clearing angle (CCA) is derived,revealing the mechanism by which the saturation current angle affects the stability of the system. In addition,a setting method of current saturation angle that can enhance the transient stability margin is proposed in this paper,which not only prevents the system from being locked into the current limiting mode after fault clearance but also achieves the maximum critical clearing angle and deceleration area. Finally,simulations based on MATLAB/Simulink are carried out to verify the correctness of the expression of critical clearing angle and setting method of current saturation angle.
format Article
id doaj-art-7fc89f9486c747d4a6b5cbdbff68d207
institution DOAJ
issn 2096-3203
language zho
publishDate 2025-03-01
publisher Editorial Department of Electric Power Engineering Technology
record_format Article
series 电力工程技术
spelling doaj-art-7fc89f9486c747d4a6b5cbdbff68d2072025-08-20T03:16:46ZzhoEditorial Department of Electric Power Engineering Technology电力工程技术2096-32032025-03-0144231210.12158/j.2096-3203.2025.02.001liujingruiTransient stability criterion of grid-forming converter based on DC voltage synchronization control considering current limitJingrui LIU0Zengze TU1Yufei ZHANG2Yang ZHANG3Jiapeng LI4Yujun LI5School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,ChinaSchool of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,ChinaSchool of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,ChinaSchool of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,ChinaSchool of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,ChinaSchool of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,ChinaIn order to address the synchronization stability of grid-forming converters considering current limiting constraints,a switching dynamic model of the system of a single converter connected to the grid based on direct current voltage synchronization control (DVSC) strategy considering current limiting is established in this paper. Grid-forming converters without current limiting constraints will only operate in the constant voltage control mode after fault clearance,while those with current limiting constraints may stabilize in different modes like constant voltage control mode or constant current control mode. Therefore,the transient stability of studied model is analyzed using the segmental equal area criteria (SEAC) in this paper and the analytical expression of the critical clearing angle (CCA) is derived,revealing the mechanism by which the saturation current angle affects the stability of the system. In addition,a setting method of current saturation angle that can enhance the transient stability margin is proposed in this paper,which not only prevents the system from being locked into the current limiting mode after fault clearance but also achieves the maximum critical clearing angle and deceleration area. Finally,simulations based on MATLAB/Simulink are carried out to verify the correctness of the expression of critical clearing angle and setting method of current saturation angle.https://doi.org/10.12158/j.2096-3203.2025.02.001direct current voltage synchronization control (dvsc)grid-forming convertercurrent limitingcritical clearing angle (cca)saturation current angletransient stability
spellingShingle Jingrui LIU
Zengze TU
Yufei ZHANG
Yang ZHANG
Jiapeng LI
Yujun LI
Transient stability criterion of grid-forming converter based on DC voltage synchronization control considering current limit
电力工程技术
direct current voltage synchronization control (dvsc)
grid-forming converter
current limiting
critical clearing angle (cca)
saturation current angle
transient stability
title Transient stability criterion of grid-forming converter based on DC voltage synchronization control considering current limit
title_full Transient stability criterion of grid-forming converter based on DC voltage synchronization control considering current limit
title_fullStr Transient stability criterion of grid-forming converter based on DC voltage synchronization control considering current limit
title_full_unstemmed Transient stability criterion of grid-forming converter based on DC voltage synchronization control considering current limit
title_short Transient stability criterion of grid-forming converter based on DC voltage synchronization control considering current limit
title_sort transient stability criterion of grid forming converter based on dc voltage synchronization control considering current limit
topic direct current voltage synchronization control (dvsc)
grid-forming converter
current limiting
critical clearing angle (cca)
saturation current angle
transient stability
url https://doi.org/10.12158/j.2096-3203.2025.02.001
work_keys_str_mv AT jingruiliu transientstabilitycriterionofgridformingconverterbasedondcvoltagesynchronizationcontrolconsideringcurrentlimit
AT zengzetu transientstabilitycriterionofgridformingconverterbasedondcvoltagesynchronizationcontrolconsideringcurrentlimit
AT yufeizhang transientstabilitycriterionofgridformingconverterbasedondcvoltagesynchronizationcontrolconsideringcurrentlimit
AT yangzhang transientstabilitycriterionofgridformingconverterbasedondcvoltagesynchronizationcontrolconsideringcurrentlimit
AT jiapengli transientstabilitycriterionofgridformingconverterbasedondcvoltagesynchronizationcontrolconsideringcurrentlimit
AT yujunli transientstabilitycriterionofgridformingconverterbasedondcvoltagesynchronizationcontrolconsideringcurrentlimit