Experimental Investigation of post-installed anchors’ behavior under axial tensile force

"In this research, the ultimate bond capacity of post-installed anchors for adhesives (three brands: HITRE10, ROX-GU80 and DUBELLF1331) and grouts (FLO-GROUT2) has been evaluated experimentally and compared with the reference cast-in-place anchors. In addition, a parametric study has been condu...

Full description

Saved in:
Bibliographic Details
Main Authors: Deedar A. Hussein, Sarkawt Asaad Sarkawt
Format: Article
Language:English
Published: Erbil Polytechnic University 2023-09-01
Series:Polytechnic Journal
Subjects:
Online Access:https://polytechnic-journal.epu.edu.iq/home/vol13/iss1/22
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850215163684192256
author Deedar A. Hussein
Sarkawt Asaad Sarkawt
author_facet Deedar A. Hussein
Sarkawt Asaad Sarkawt
author_sort Deedar A. Hussein
collection DOAJ
description "In this research, the ultimate bond capacity of post-installed anchors for adhesives (three brands: HITRE10, ROX-GU80 and DUBELLF1331) and grouts (FLO-GROUT2) has been evaluated experimentally and compared with the reference cast-in-place anchors. In addition, a parametric study has been conducted to assess the effects of the anchor diameter (10, 12, 16 mm), anchor embedded length (5db,10db and 15db) and the cleaning method on the adhesive and grouted anchors. Among the used three adhesive brands, the anchor adhesive Brand “HIT-RE10” had the largest bond capacity. Furthermore, apart from the small embedded length (5db), the experimental results showed that the ultimate bond capacity of the post installed anchors was higher than the reference cast-in-place anchors. In the same embedded length range (>5db), the average bond stress decreased with the increase in the embedment length. With respect to the effect of the increase in the embedment length and the diameter parameters, the results showed that there is a corresponding increase in the ultimate bond capacity in both the adhesive and the grout anchors. For the cleaning method parameter in adhesive anchors, the cleaning with air only achieved a higher ultimate bond capacity compared with cleaning using air plus wire brush; however, in grout anchors, the cleaning using air plus wire brush produced the larger capacity. The results also showed that cleaning the holes of the adhesive anchors by washing with water and wire brush produced the highest ultimate bond capacity compared with the other two cleaning method. "
format Article
id doaj-art-7f69a8a2815943c9889361ffaabde1a1
institution OA Journals
issn 2707-7799
language English
publishDate 2023-09-01
publisher Erbil Polytechnic University
record_format Article
series Polytechnic Journal
spelling doaj-art-7f69a8a2815943c9889361ffaabde1a12025-08-20T02:08:42ZengErbil Polytechnic UniversityPolytechnic Journal2707-77992023-09-01131230239https://doi.org/10.59341/2707-7799.1835Experimental Investigation of post-installed anchors’ behavior under axial tensile forceDeedar A. Hussein0Sarkawt Asaad Sarkawt1Department of civil Engineering, Erbil technical engineering college, Erbil polytechnic university, Erbil, Kurdistan Region, Iraq.Department of civil Engineering, Erbil technical engineering college, Erbil polytechnic university, Erbil, Kurdistan Region, Iraq."In this research, the ultimate bond capacity of post-installed anchors for adhesives (three brands: HITRE10, ROX-GU80 and DUBELLF1331) and grouts (FLO-GROUT2) has been evaluated experimentally and compared with the reference cast-in-place anchors. In addition, a parametric study has been conducted to assess the effects of the anchor diameter (10, 12, 16 mm), anchor embedded length (5db,10db and 15db) and the cleaning method on the adhesive and grouted anchors. Among the used three adhesive brands, the anchor adhesive Brand “HIT-RE10” had the largest bond capacity. Furthermore, apart from the small embedded length (5db), the experimental results showed that the ultimate bond capacity of the post installed anchors was higher than the reference cast-in-place anchors. In the same embedded length range (>5db), the average bond stress decreased with the increase in the embedment length. With respect to the effect of the increase in the embedment length and the diameter parameters, the results showed that there is a corresponding increase in the ultimate bond capacity in both the adhesive and the grout anchors. For the cleaning method parameter in adhesive anchors, the cleaning with air only achieved a higher ultimate bond capacity compared with cleaning using air plus wire brush; however, in grout anchors, the cleaning using air plus wire brush produced the larger capacity. The results also showed that cleaning the holes of the adhesive anchors by washing with water and wire brush produced the highest ultimate bond capacity compared with the other two cleaning method. "https://polytechnic-journal.epu.edu.iq/home/vol13/iss1/22 post installed anchors,epoxy,grout,average bond stress,pull-out test
spellingShingle Deedar A. Hussein
Sarkawt Asaad Sarkawt
Experimental Investigation of post-installed anchors’ behavior under axial tensile force
Polytechnic Journal
post installed anchors,
epoxy,
grout,
average bond stress,
pull-out test
title Experimental Investigation of post-installed anchors’ behavior under axial tensile force
title_full Experimental Investigation of post-installed anchors’ behavior under axial tensile force
title_fullStr Experimental Investigation of post-installed anchors’ behavior under axial tensile force
title_full_unstemmed Experimental Investigation of post-installed anchors’ behavior under axial tensile force
title_short Experimental Investigation of post-installed anchors’ behavior under axial tensile force
title_sort experimental investigation of post installed anchors behavior under axial tensile force
topic post installed anchors,
epoxy,
grout,
average bond stress,
pull-out test
url https://polytechnic-journal.epu.edu.iq/home/vol13/iss1/22
work_keys_str_mv AT deedarahussein experimentalinvestigationofpostinstalledanchorsbehaviorunderaxialtensileforce
AT sarkawtasaadsarkawt experimentalinvestigationofpostinstalledanchorsbehaviorunderaxialtensileforce