Avaliação da resistência à tração entre sistemas para reparo de revestimento estético e liga de níquel-cromo.

Objectives: This study evaluated the adhesive bond strength between four repair systems and a nickel-chromium alloy for metalceramic crowns. Material and Methods: Twenty-four blocks of nickel-chromium with dimensions of 5x5x5 mm were cast and divided into four groups of six blocks. Each group w...

Full description

Saved in:
Bibliographic Details
Main Authors: Osvaldo Daniel Andreatta Filho, Renato Sussumu Nishioka
Format: Article
Language:English
Published: Universidade Estadual Paulista 2012-08-01
Series:Brazilian Dental Science
Subjects:
Online Access:https://ojs.ict.unesp.br/index.php/cob/article/view/775
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849228661005221888
author Osvaldo Daniel Andreatta Filho
Renato Sussumu Nishioka
author_facet Osvaldo Daniel Andreatta Filho
Renato Sussumu Nishioka
author_sort Osvaldo Daniel Andreatta Filho
collection DOAJ
description Objectives: This study evaluated the adhesive bond strength between four repair systems and a nickel-chromium alloy for metalceramic crowns. Material and Methods: Twenty-four blocks of nickel-chromium with dimensions of 5x5x5 mm were cast and divided into four groups of six blocks. Each group was conditioned with the following surface treatments: G1- sandblasting with Al2O3 (50 µm) + Alloy Primer (Kuraray); G2-sandblasting with Al2O3 (50 µm) + 37% phosphoric acid + Adper Single Bond 2 (3M); G3- Cojet-Sand System (3M); G4- Cojet-Sand System (3M) + Adper Single Bond 2 (3M). On the conditioned face of the metal blocks was applied composite resin until obtaining a symmetrical resin block. These sets were split up, obtained 96 samples of 10x1x1 mm, with adhesive surface of 1 mm². After thermocycling (500 cycles at 5-55 °C) all samples were submitted to the microtensile test in an universal test machine (EMIC) with crosshead speed of 1mm/min. Results: Means and standard deviation of bond strength (MPa) were: G1: 24.49 ± 4.80, G2: 19.51 ± 3.90, G3: 38.93 ± 3.37 and G4: 36.49 ± 3.45. The data were analyzed by the analysis of variance test (ANOVA) indicating that values of bond strength of the group G3 and G4 were significantly larger than the groups G1 and G2. Conclusion: It was concluded that the NiCr alloy conditioned with Cojet-Sand (G3 and G4) increased the values of bond strength to composite resin compared to the surface treatments of groups G1 and G2.
format Article
id doaj-art-7c49bece3b594e708b292ce32edda529
institution Kabale University
issn 2178-6011
language English
publishDate 2012-08-01
publisher Universidade Estadual Paulista
record_format Article
series Brazilian Dental Science
spelling doaj-art-7c49bece3b594e708b292ce32edda5292025-08-22T17:56:46ZengUniversidade Estadual PaulistaBrazilian Dental Science2178-60112012-08-01143/410.14295/bds.2011.v14i3/4.775Avaliação da resistência à tração entre sistemas para reparo de revestimento estético e liga de níquel-cromo.Osvaldo Daniel Andreatta Filho0Renato Sussumu Nishioka1Faculdade de Odontologia de São José dos Campos-UNESPFaculdade de Odontologia de São José dos Campos - UNESP Objectives: This study evaluated the adhesive bond strength between four repair systems and a nickel-chromium alloy for metalceramic crowns. Material and Methods: Twenty-four blocks of nickel-chromium with dimensions of 5x5x5 mm were cast and divided into four groups of six blocks. Each group was conditioned with the following surface treatments: G1- sandblasting with Al2O3 (50 µm) + Alloy Primer (Kuraray); G2-sandblasting with Al2O3 (50 µm) + 37% phosphoric acid + Adper Single Bond 2 (3M); G3- Cojet-Sand System (3M); G4- Cojet-Sand System (3M) + Adper Single Bond 2 (3M). On the conditioned face of the metal blocks was applied composite resin until obtaining a symmetrical resin block. These sets were split up, obtained 96 samples of 10x1x1 mm, with adhesive surface of 1 mm². After thermocycling (500 cycles at 5-55 °C) all samples were submitted to the microtensile test in an universal test machine (EMIC) with crosshead speed of 1mm/min. Results: Means and standard deviation of bond strength (MPa) were: G1: 24.49 ± 4.80, G2: 19.51 ± 3.90, G3: 38.93 ± 3.37 and G4: 36.49 ± 3.45. The data were analyzed by the analysis of variance test (ANOVA) indicating that values of bond strength of the group G3 and G4 were significantly larger than the groups G1 and G2. Conclusion: It was concluded that the NiCr alloy conditioned with Cojet-Sand (G3 and G4) increased the values of bond strength to composite resin compared to the surface treatments of groups G1 and G2. https://ojs.ict.unesp.br/index.php/cob/article/view/775Metal alloyscomposite resinsurface treatments
spellingShingle Osvaldo Daniel Andreatta Filho
Renato Sussumu Nishioka
Avaliação da resistência à tração entre sistemas para reparo de revestimento estético e liga de níquel-cromo.
Brazilian Dental Science
Metal alloys
composite resin
surface treatments
title Avaliação da resistência à tração entre sistemas para reparo de revestimento estético e liga de níquel-cromo.
title_full Avaliação da resistência à tração entre sistemas para reparo de revestimento estético e liga de níquel-cromo.
title_fullStr Avaliação da resistência à tração entre sistemas para reparo de revestimento estético e liga de níquel-cromo.
title_full_unstemmed Avaliação da resistência à tração entre sistemas para reparo de revestimento estético e liga de níquel-cromo.
title_short Avaliação da resistência à tração entre sistemas para reparo de revestimento estético e liga de níquel-cromo.
title_sort avaliacao da resistencia a tracao entre sistemas para reparo de revestimento estetico e liga de niquel cromo
topic Metal alloys
composite resin
surface treatments
url https://ojs.ict.unesp.br/index.php/cob/article/view/775
work_keys_str_mv AT osvaldodanielandreattafilho avaliacaodaresistenciaatracaoentresistemasparareparoderevestimentoesteticoeligadeniquelcromo
AT renatosussumunishioka avaliacaodaresistenciaatracaoentresistemasparareparoderevestimentoesteticoeligadeniquelcromo