On the issue of achieving subpicometric resolution by acousto-optic two-channel laser displacement interferometer with two different frequency photodetectors

The article discusses an acousto-optical (AO) heterodyne laser displacement interferometer (LDI) with two different-frequency photodetectors: highfrequency (HF) and low-frequency (LF) low-noise, working with «fast inaccurate» and «slow accurate» measuring channels, respectively. The mode of ope...

Full description

Saved in:
Bibliographic Details
Main Author: E. V. Leun
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2022-04-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%202%20(182)%20(%D0%9E%D0%9D%D0%92)/110-118%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%95.%20%D0%92..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832570258669436928
author E. V. Leun
author_facet E. V. Leun
author_sort E. V. Leun
collection DOAJ
description The article discusses an acousto-optical (AO) heterodyne laser displacement interferometer (LDI) with two different-frequency photodetectors: highfrequency (HF) and low-frequency (LF) low-noise, working with «fast inaccurate» and «slow accurate» measuring channels, respectively. The mode of operation of AO LDI at start-stop cyclic motions of objects is described, which provides high resolution at the initial and final stages of motions with low speeds of motion. A metrological analysis of the «slow accurate» channel is carried out taking into account the noise frequency characteristics of photodetectors with the formation of its so-called «optimistic» and «pessimistic» variants. Based on the metrological analysis carried out, the frequency ranges of the signal are determined, which allow achieving the resolution of AO LDI subpicometric values at low speeds.
format Article
id doaj-art-7b06d1ca2d2848ce8e3aea3a38824503
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2022-04-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-7b06d1ca2d2848ce8e3aea3a388245032025-02-02T15:57:41ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412022-04-012 (182)11011810.25206/1813-8225-2022-182-110-118On the issue of achieving subpicometric resolution by acousto-optic two-channel laser displacement interferometer with two different frequency photodetectorsE. V. Leun0Lavochkin AssociationThe article discusses an acousto-optical (AO) heterodyne laser displacement interferometer (LDI) with two different-frequency photodetectors: highfrequency (HF) and low-frequency (LF) low-noise, working with «fast inaccurate» and «slow accurate» measuring channels, respectively. The mode of operation of AO LDI at start-stop cyclic motions of objects is described, which provides high resolution at the initial and final stages of motions with low speeds of motion. A metrological analysis of the «slow accurate» channel is carried out taking into account the noise frequency characteristics of photodetectors with the formation of its so-called «optimistic» and «pessimistic» variants. Based on the metrological analysis carried out, the frequency ranges of the signal are determined, which allow achieving the resolution of AO LDI subpicometric values at low speeds.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%202%20(182)%20(%D0%9E%D0%9D%D0%92)/110-118%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%95.%20%D0%92..pdflaser displacement interferometerphaselocked frequency systemacousto-optic modulatorphotodetector noisesignal jitterpicometersmallrange phase meter
spellingShingle E. V. Leun
On the issue of achieving subpicometric resolution by acousto-optic two-channel laser displacement interferometer with two different frequency photodetectors
Омский научный вестник
laser displacement interferometer
phaselocked frequency system
acousto-optic modulator
photodetector noise
signal jitter
picometer
smallrange phase meter
title On the issue of achieving subpicometric resolution by acousto-optic two-channel laser displacement interferometer with two different frequency photodetectors
title_full On the issue of achieving subpicometric resolution by acousto-optic two-channel laser displacement interferometer with two different frequency photodetectors
title_fullStr On the issue of achieving subpicometric resolution by acousto-optic two-channel laser displacement interferometer with two different frequency photodetectors
title_full_unstemmed On the issue of achieving subpicometric resolution by acousto-optic two-channel laser displacement interferometer with two different frequency photodetectors
title_short On the issue of achieving subpicometric resolution by acousto-optic two-channel laser displacement interferometer with two different frequency photodetectors
title_sort on the issue of achieving subpicometric resolution by acousto optic two channel laser displacement interferometer with two different frequency photodetectors
topic laser displacement interferometer
phaselocked frequency system
acousto-optic modulator
photodetector noise
signal jitter
picometer
smallrange phase meter
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%202%20(182)%20(%D0%9E%D0%9D%D0%92)/110-118%20%D0%9B%D0%B5%D1%83%D0%BD%20%D0%95.%20%D0%92..pdf
work_keys_str_mv AT evleun ontheissueofachievingsubpicometricresolutionbyacoustooptictwochannellaserdisplacementinterferometerwithtwodifferentfrequencyphotodetectors