Detectability of small blood vessels and flat boundaries of soft tissues in the ultrasonic pulse echo method

The detectability of a small blood vessel of a radius 0.1 mm by the pulse echo ultrasonic method using a frequency of 2.5 MHz was estimated. It was assumed that the vessel was surrounded by a homogeneous soft tissue (i.e. causing no reflection) and was in the near region of the far field radiated in...

Full description

Saved in:
Bibliographic Details
Main Author: L. FILIPCZYŃSKI
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2016-03-01
Series:Archives of Acoustics
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/3293
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849318791990738944
author L. FILIPCZYŃSKI
author_facet L. FILIPCZYŃSKI
author_sort L. FILIPCZYŃSKI
collection DOAJ
description The detectability of a small blood vessel of a radius 0.1 mm by the pulse echo ultrasonic method using a frequency of 2.5 MHz was estimated. It was assumed that the vessel was surrounded by a homogeneous soft tissue (i.e. causing no reflection) and was in the near region of the far field radiated in a continuous manner by a plane transducer of a diameter of 2 cm. The soft tissue and the walls of the vessel were assumed to have the same elastic properties as those of a liquid. The measurements were carried out in a plane polar coordinate system, where the incident wave, the reflected wave and the wave penetrating into the vessel were expressed in terms of Bessel and HankeI functions. The boundary conditions were assumed in the form of the equality of the acoustic pressures and the normal components of acoustic velocitits on each side of the surface of the vessel. Thence the magnitude of the reflected wave was determined. The losses of the signal due to the reflection of the wave, its divergence and absorption, are shown in the form of a graph from which it can be seen that the signal from the vessel considered is essentially detectible, although it lies near the noise level, and is critically dependent on the distance from the transducer due to attenuation in the tissues penetrated. The detectability of the plane boundaries of soft tissues was also determined, indicating that at a distance of 20 cm from the transducer a difference in the characteristic acoustic impedance of the tissues of 0.2% is sufficient to give a detectable echo.
format Article
id doaj-art-79bbb5147b64432ca5ada69a2be46f3a
institution Kabale University
issn 0137-5075
2300-262X
language English
publishDate 2016-03-01
publisher Institute of Fundamental Technological Research Polish Academy of Sciences
record_format Article
series Archives of Acoustics
spelling doaj-art-79bbb5147b64432ca5ada69a2be46f3a2025-08-20T03:50:44ZengInstitute of Fundamental Technological Research Polish Academy of SciencesArchives of Acoustics0137-50752300-262X2016-03-0161Detectability of small blood vessels and flat boundaries of soft tissues in the ultrasonic pulse echo methodL. FILIPCZYŃSKI0Institute of Fundamental Technological Research Polish Academy of SciencesThe detectability of a small blood vessel of a radius 0.1 mm by the pulse echo ultrasonic method using a frequency of 2.5 MHz was estimated. It was assumed that the vessel was surrounded by a homogeneous soft tissue (i.e. causing no reflection) and was in the near region of the far field radiated in a continuous manner by a plane transducer of a diameter of 2 cm. The soft tissue and the walls of the vessel were assumed to have the same elastic properties as those of a liquid. The measurements were carried out in a plane polar coordinate system, where the incident wave, the reflected wave and the wave penetrating into the vessel were expressed in terms of Bessel and HankeI functions. The boundary conditions were assumed in the form of the equality of the acoustic pressures and the normal components of acoustic velocitits on each side of the surface of the vessel. Thence the magnitude of the reflected wave was determined. The losses of the signal due to the reflection of the wave, its divergence and absorption, are shown in the form of a graph from which it can be seen that the signal from the vessel considered is essentially detectible, although it lies near the noise level, and is critically dependent on the distance from the transducer due to attenuation in the tissues penetrated. The detectability of the plane boundaries of soft tissues was also determined, indicating that at a distance of 20 cm from the transducer a difference in the characteristic acoustic impedance of the tissues of 0.2% is sufficient to give a detectable echo.https://acoustics.ippt.pan.pl/index.php/aa/article/view/3293
spellingShingle L. FILIPCZYŃSKI
Detectability of small blood vessels and flat boundaries of soft tissues in the ultrasonic pulse echo method
Archives of Acoustics
title Detectability of small blood vessels and flat boundaries of soft tissues in the ultrasonic pulse echo method
title_full Detectability of small blood vessels and flat boundaries of soft tissues in the ultrasonic pulse echo method
title_fullStr Detectability of small blood vessels and flat boundaries of soft tissues in the ultrasonic pulse echo method
title_full_unstemmed Detectability of small blood vessels and flat boundaries of soft tissues in the ultrasonic pulse echo method
title_short Detectability of small blood vessels and flat boundaries of soft tissues in the ultrasonic pulse echo method
title_sort detectability of small blood vessels and flat boundaries of soft tissues in the ultrasonic pulse echo method
url https://acoustics.ippt.pan.pl/index.php/aa/article/view/3293
work_keys_str_mv AT lfilipczynski detectabilityofsmallbloodvesselsandflatboundariesofsofttissuesintheultrasonicpulseechomethod