Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediated dilatation, and to explore how these two variables change when endothelial dysfunction is experimentally induced. Method: The experimental study was conducted at the departments of p...

Full description

Saved in:
Bibliographic Details
Main Authors: Nada Abdul Salam, Amal Yousif Al-Yasiri, Bassam Talib Al-Gailani
Format: Article
Language:English
Published: Pakistan Medical Association 2024-09-01
Series:Journal of the Pakistan Medical Association
Online Access:https://jpma.org.pk/index.php/public_html/article/view/21787
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850094620507111424
author Nada Abdul Salam
Amal Yousif Al-Yasiri
Bassam Talib Al-Gailani
author_facet Nada Abdul Salam
Amal Yousif Al-Yasiri
Bassam Talib Al-Gailani
author_sort Nada Abdul Salam
collection DOAJ
description Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediated dilatation, and to explore how these two variables change when endothelial dysfunction is experimentally induced. Method: The experimental study was conducted at the departments of physiology at the College of Medicine, Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, to May 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation technique on the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured during reactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and a simultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrograde shear rates. The correlation between variables was calculated in Excel running on the Windows operating system. Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index 25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normal endothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and the difference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endothelium relative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05). Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may be used to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulse wave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediated dilatation protocol, than pulse transit time. Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave, Endothelium, Running
format Article
id doaj-art-794e5b1e2f704185a09129ec0a64d27b
institution DOAJ
issn 0030-9982
language English
publishDate 2024-09-01
publisher Pakistan Medical Association
record_format Article
series Journal of the Pakistan Medical Association
spelling doaj-art-794e5b1e2f704185a09129ec0a64d27b2025-08-20T02:41:37ZengPakistan Medical AssociationJournal of the Pakistan Medical Association0030-99822024-09-017410 (Supple-08)10.47391/JPMA-BAGH-16-10Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatationNada Abdul Salam0Amal Yousif Al-Yasiri1Bassam Talib Al-Gailani2Department of Physiology, Mustansiriyah University, Baghdad, Iraq. Department of Basic Sciences, University of Baghdad.Department of Physiology, Mustansiriyah University, Baghdad, Iraq. Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediated dilatation, and to explore how these two variables change when endothelial dysfunction is experimentally induced. Method: The experimental study was conducted at the departments of physiology at the College of Medicine, Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, to May 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation technique on the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured during reactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and a simultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrograde shear rates. The correlation between variables was calculated in Excel running on the Windows operating system. Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index 25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normal endothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and the difference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endothelium relative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05). Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may be used to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulse wave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediated dilatation protocol, than pulse transit time. Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave, Endothelium, Running https://jpma.org.pk/index.php/public_html/article/view/21787
spellingShingle Nada Abdul Salam
Amal Yousif Al-Yasiri
Bassam Talib Al-Gailani
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
Journal of the Pakistan Medical Association
title Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
title_full Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
title_fullStr Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
title_full_unstemmed Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
title_short Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
title_sort pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
url https://jpma.org.pk/index.php/public_html/article/view/21787
work_keys_str_mv AT nadaabdulsalam pulsetransmissiontimeandamplitudeofdigitalpulsewavedeterminedbyfingertipplethysmographyasasurrogatemarkerofbrachialarteryflowmediateddilatation
AT amalyousifalyasiri pulsetransmissiontimeandamplitudeofdigitalpulsewavedeterminedbyfingertipplethysmographyasasurrogatemarkerofbrachialarteryflowmediateddilatation
AT bassamtalibalgailani pulsetransmissiontimeandamplitudeofdigitalpulsewavedeterminedbyfingertipplethysmographyasasurrogatemarkerofbrachialarteryflowmediateddilatation