Beam shaping assembly study for BNCT facility based on a 2.5 MeV proton accelerator on Li target
Abstract A new study for a boron neutron capture therapy irradiation facility, based on a 2.5 MeV proton accelerator on a thick Li target as neutron converter, is presented here. The beam shaping assembly (BSA) modeling has been performed with the use of the MCNP5 Monte Carlo code. The fast (i.e., &...