Horizontal Loading Tests on Disconnected Piled Rafts and a Simplified Method to Evaluate the Horizontal Bearing Capacity

Disconnected piled raft (DPR) foundations have been widely adopted as an effective foundation system where the piles are separated from the raft by a granular layer, which can limit the shear forces and moments transmitted between the raft and the piles. Thus, DPR foundations may avoid the problem o...

Full description

Saved in:
Bibliographic Details
Main Authors: Xiao-jun Zhu, Kang Fei, Sheng-wei Wang
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2018/3956509
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849410261128052736
author Xiao-jun Zhu
Kang Fei
Sheng-wei Wang
author_facet Xiao-jun Zhu
Kang Fei
Sheng-wei Wang
author_sort Xiao-jun Zhu
collection DOAJ
description Disconnected piled raft (DPR) foundations have been widely adopted as an effective foundation system where the piles are separated from the raft by a granular layer, which can limit the shear forces and moments transmitted between the raft and the piles. Thus, DPR foundations may avoid the problem of horizontal forces, such as those from an earthquake or dynamic loads, which damage the structural connection between the pile head and raft. A series of static horizontal loading tests were carried out on three types of foundation models, i.e., piled raft, disconnected piled raft, and raft alone models, on fine sand using a geotechnical model in a 1 g field. In this paper, the influences of vertical loading and interposed layer thickness were presented and discussed. The results showed that most of the horizontal force was carried by raft/interposed layer friction in the DPR foundation type, and the shear force and moment of the piles were greatly reduced due to the gap between the raft and the heads of the piles. The tested foundations were simulated using a simplified method with theoretical equations derived by making several approximations and assumptions. The simulated results agreed well with the test results.
format Article
id doaj-art-78afc565cb7e405f89ef10bd24ec0416
institution Kabale University
issn 1687-8086
1687-8094
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-78afc565cb7e405f89ef10bd24ec04162025-08-20T03:35:11ZengWileyAdvances in Civil Engineering1687-80861687-80942018-01-01201810.1155/2018/39565093956509Horizontal Loading Tests on Disconnected Piled Rafts and a Simplified Method to Evaluate the Horizontal Bearing CapacityXiao-jun Zhu0Kang Fei1Sheng-wei Wang2College of Civil Science and Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, ChinaCollege of Civil Science and Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, ChinaCollege of Civil Science and Engineering, Yangzhou University, Yangzhou 225127, Jiangsu, ChinaDisconnected piled raft (DPR) foundations have been widely adopted as an effective foundation system where the piles are separated from the raft by a granular layer, which can limit the shear forces and moments transmitted between the raft and the piles. Thus, DPR foundations may avoid the problem of horizontal forces, such as those from an earthquake or dynamic loads, which damage the structural connection between the pile head and raft. A series of static horizontal loading tests were carried out on three types of foundation models, i.e., piled raft, disconnected piled raft, and raft alone models, on fine sand using a geotechnical model in a 1 g field. In this paper, the influences of vertical loading and interposed layer thickness were presented and discussed. The results showed that most of the horizontal force was carried by raft/interposed layer friction in the DPR foundation type, and the shear force and moment of the piles were greatly reduced due to the gap between the raft and the heads of the piles. The tested foundations were simulated using a simplified method with theoretical equations derived by making several approximations and assumptions. The simulated results agreed well with the test results.http://dx.doi.org/10.1155/2018/3956509
spellingShingle Xiao-jun Zhu
Kang Fei
Sheng-wei Wang
Horizontal Loading Tests on Disconnected Piled Rafts and a Simplified Method to Evaluate the Horizontal Bearing Capacity
Advances in Civil Engineering
title Horizontal Loading Tests on Disconnected Piled Rafts and a Simplified Method to Evaluate the Horizontal Bearing Capacity
title_full Horizontal Loading Tests on Disconnected Piled Rafts and a Simplified Method to Evaluate the Horizontal Bearing Capacity
title_fullStr Horizontal Loading Tests on Disconnected Piled Rafts and a Simplified Method to Evaluate the Horizontal Bearing Capacity
title_full_unstemmed Horizontal Loading Tests on Disconnected Piled Rafts and a Simplified Method to Evaluate the Horizontal Bearing Capacity
title_short Horizontal Loading Tests on Disconnected Piled Rafts and a Simplified Method to Evaluate the Horizontal Bearing Capacity
title_sort horizontal loading tests on disconnected piled rafts and a simplified method to evaluate the horizontal bearing capacity
url http://dx.doi.org/10.1155/2018/3956509
work_keys_str_mv AT xiaojunzhu horizontalloadingtestsondisconnectedpiledraftsandasimplifiedmethodtoevaluatethehorizontalbearingcapacity
AT kangfei horizontalloadingtestsondisconnectedpiledraftsandasimplifiedmethodtoevaluatethehorizontalbearingcapacity
AT shengweiwang horizontalloadingtestsondisconnectedpiledraftsandasimplifiedmethodtoevaluatethehorizontalbearingcapacity