Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs

There is a large number of factors that affect the long-term permissible load currents of power cables, including environmental conditions, the method of laying, as well as the geometric, thermal and electrical characteristics of the cable structure. The catalogs of manufacturers of power cables wit...

Full description

Saved in:
Bibliographic Details
Main Author: M. E. Vysotski
Format: Article
Language:Russian
Published: Belarusian National Technical University 2024-08-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/2388
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543716609359872
author M. E. Vysotski
author_facet M. E. Vysotski
author_sort M. E. Vysotski
collection DOAJ
description There is a large number of factors that affect the long-term permissible load currents of power cables, including environmental conditions, the method of laying, as well as the geometric, thermal and electrical characteristics of the cable structure. The catalogs of manufacturers of power cables with cross-linked polyethylene insulation do not specify the long-term permissible load currents, which would take into account the cross-sectional area of the screen, the presence of aluminum polymer tape and armor made of aluminum wires. These components can have a significant impact on the permissible load due to the currents induced in them during two-way grounding, which leads to additional heating of the cable. The purpose of this study is to analyze the influence of the above-mentioned factors on the long-term permissible load currents. The paper presents formulas for calculating the long-term permissible load current, which take into account the design features of the cables under consideration. The calculations have shown that the permissible load can decrease by 6 % with an increase in the cross-sectional area of the screen from the nominal row by one step. The introduction of an aluminum polymer tape into the cable structure changes the permissible load by no more than 2 %. The presence of armor can lead to a decrease in the permissible load by up to 18 % and its increase by up to 13 %, depending on the section of the core and screen, the method and conditions of laying. The calculation results obtained differ from the catalogdata by up to 25%. While the obtained errorsindicatetheneed to formcoefficientsfor a moreaccuratedetermination of the long-term permissible cable currents.
format Article
id doaj-art-784315283e7d4e4780aef18104435084
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2024-08-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-784315283e7d4e4780aef181044350842025-02-03T11:34:32ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412024-08-0167430031410.21122/1029-7448-2024-67-4-300-3141899Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various DesignsM. E. Vysotski0Belarussian National Technical UniversityThere is a large number of factors that affect the long-term permissible load currents of power cables, including environmental conditions, the method of laying, as well as the geometric, thermal and electrical characteristics of the cable structure. The catalogs of manufacturers of power cables with cross-linked polyethylene insulation do not specify the long-term permissible load currents, which would take into account the cross-sectional area of the screen, the presence of aluminum polymer tape and armor made of aluminum wires. These components can have a significant impact on the permissible load due to the currents induced in them during two-way grounding, which leads to additional heating of the cable. The purpose of this study is to analyze the influence of the above-mentioned factors on the long-term permissible load currents. The paper presents formulas for calculating the long-term permissible load current, which take into account the design features of the cables under consideration. The calculations have shown that the permissible load can decrease by 6 % with an increase in the cross-sectional area of the screen from the nominal row by one step. The introduction of an aluminum polymer tape into the cable structure changes the permissible load by no more than 2 %. The presence of armor can lead to a decrease in the permissible load by up to 18 % and its increase by up to 13 %, depending on the section of the core and screen, the method and conditions of laying. The calculation results obtained differ from the catalogdata by up to 25%. While the obtained errorsindicatetheneed to formcoefficientsfor a moreaccuratedetermination of the long-term permissible cable currents.https://energy.bntu.by/jour/article/view/2388cable linescross-sectional areaaluminum polymer tapealuminum wire armorcopper wire screen
spellingShingle M. E. Vysotski
Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
cable lines
cross-sectional area
aluminum polymer tape
aluminum wire armor
copper wire screen
title Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs
title_full Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs
title_fullStr Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs
title_full_unstemmed Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs
title_short Long-Term Permissible Load Currents of Single-Core Cables with a Voltage of 10 kV with Cross-Linked Polyethylene Insulation of Various Designs
title_sort long term permissible load currents of single core cables with a voltage of 10 kv with cross linked polyethylene insulation of various designs
topic cable lines
cross-sectional area
aluminum polymer tape
aluminum wire armor
copper wire screen
url https://energy.bntu.by/jour/article/view/2388
work_keys_str_mv AT mevysotski longtermpermissibleloadcurrentsofsinglecorecableswithavoltageof10kvwithcrosslinkedpolyethyleneinsulationofvariousdesigns