Teleultrasonido ocular durante la pandemia de COVID-19

Objective: To determine the concordance in ultrasound diagnoses made by an ophthalmologist who is not an expert in ocular ultrasound (ONE) guided virtually by an expert in ocular ultrasound (EUO1) and those made by a second expert in ocular ultrasound (EUO2). Method: Observational, cross-sectional s...

Full description

Saved in:
Bibliographic Details
Main Authors: Mariana Mayorquín-Ruiz, Ana P. Bustamante-Vargas, Catalina Becerra-Revollo, Carlos Ríos-Elizondo, David Berrones-Medina, Gerardo M. Hernández-Valero, Samuel Peña-Ortiz, Mariam Cernichiaro-Espinosa
Format: Article
Language:English
Published: Jaypee Brothers Medical Publisher 2023-01-01
Series:Revista Mexicana de Oftalmología
Subjects:
Online Access:https://www.rmo.com.mx/frame_esp.php?id=344
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849717934994227200
author Mariana Mayorquín-Ruiz
Ana P. Bustamante-Vargas
Catalina Becerra-Revollo
Carlos Ríos-Elizondo
David Berrones-Medina
Gerardo M. Hernández-Valero
Samuel Peña-Ortiz
Mariam Cernichiaro-Espinosa
author_facet Mariana Mayorquín-Ruiz
Ana P. Bustamante-Vargas
Catalina Becerra-Revollo
Carlos Ríos-Elizondo
David Berrones-Medina
Gerardo M. Hernández-Valero
Samuel Peña-Ortiz
Mariam Cernichiaro-Espinosa
author_sort Mariana Mayorquín-Ruiz
collection DOAJ
description Objective: To determine the concordance in ultrasound diagnoses made by an ophthalmologist who is not an expert in ocular ultrasound (ONE) guided virtually by an expert in ocular ultrasound (EUO1) and those made by a second expert in ocular ultrasound (EUO2). Method: Observational, cross-sectional study. Patients referred to the ocular ultrasound service with media opacity were reviewed. The ONE performed the ultrasound study guided virtually by an EUO1. Subsequently, an EUO2 performed an ultrasound study on the same patient. Diagnoses and ultrasound findings of both were analyzed in a database. Results: We included 41 eyes of 24 patients referred to the ocular ultrasound service. The concordance between the ONE virtually guided by an EUO1 and the EUO2 was very high in the variables: ocular biometry, phakic state of the eye, presence of silicone in the vitreous cavity, presence of staphyloma, retinal and choroidal detachment. The variables with the least strength of correlation were: presence of posterior hyphema, description of optic nerve excavation and presence of hyaloid adhesion to the posterior pole. Conclusions: The high concordance between the ONE guided virtually by EUO1 and the EUO2, shows the possibility of developing mentoring and interconsultation through tele-ultrasound.
format Article
id doaj-art-77b02bdcb32f485aa9334bc38aaacbc5
institution DOAJ
issn 0187-4519
language English
publishDate 2023-01-01
publisher Jaypee Brothers Medical Publisher
record_format Article
series Revista Mexicana de Oftalmología
spelling doaj-art-77b02bdcb32f485aa9334bc38aaacbc52025-08-20T03:12:31ZengJaypee Brothers Medical PublisherRevista Mexicana de Oftalmología0187-45192023-01-0197610.24875/RMO.M25000260 Teleultrasonido ocular durante la pandemia de COVID-19Mariana Mayorquín-Ruiz0Ana P. Bustamante-Vargas1Catalina Becerra-Revollo2Carlos Ríos-Elizondo3David Berrones-Medina4Gerardo M. Hernández-Valero5Samuel Peña-Ortiz6Mariam Cernichiaro-Espinosa7Servicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Retina, Asociación para Evitar la Ceguera en México, Mexico City, MexicoObjective: To determine the concordance in ultrasound diagnoses made by an ophthalmologist who is not an expert in ocular ultrasound (ONE) guided virtually by an expert in ocular ultrasound (EUO1) and those made by a second expert in ocular ultrasound (EUO2). Method: Observational, cross-sectional study. Patients referred to the ocular ultrasound service with media opacity were reviewed. The ONE performed the ultrasound study guided virtually by an EUO1. Subsequently, an EUO2 performed an ultrasound study on the same patient. Diagnoses and ultrasound findings of both were analyzed in a database. Results: We included 41 eyes of 24 patients referred to the ocular ultrasound service. The concordance between the ONE virtually guided by an EUO1 and the EUO2 was very high in the variables: ocular biometry, phakic state of the eye, presence of silicone in the vitreous cavity, presence of staphyloma, retinal and choroidal detachment. The variables with the least strength of correlation were: presence of posterior hyphema, description of optic nerve excavation and presence of hyaloid adhesion to the posterior pole. Conclusions: The high concordance between the ONE guided virtually by EUO1 and the EUO2, shows the possibility of developing mentoring and interconsultation through tele-ultrasound. https://www.rmo.com.mx/frame_esp.php?id=344Ocular teleultrasound. Telemedicine. Ultrasound imaging.
spellingShingle Mariana Mayorquín-Ruiz
Ana P. Bustamante-Vargas
Catalina Becerra-Revollo
Carlos Ríos-Elizondo
David Berrones-Medina
Gerardo M. Hernández-Valero
Samuel Peña-Ortiz
Mariam Cernichiaro-Espinosa
Teleultrasonido ocular durante la pandemia de COVID-19
Revista Mexicana de Oftalmología
Ocular teleultrasound. Telemedicine. Ultrasound imaging.
title Teleultrasonido ocular durante la pandemia de COVID-19
title_full Teleultrasonido ocular durante la pandemia de COVID-19
title_fullStr Teleultrasonido ocular durante la pandemia de COVID-19
title_full_unstemmed Teleultrasonido ocular durante la pandemia de COVID-19
title_short Teleultrasonido ocular durante la pandemia de COVID-19
title_sort teleultrasonido ocular durante la pandemia de covid 19
topic Ocular teleultrasound. Telemedicine. Ultrasound imaging.
url https://www.rmo.com.mx/frame_esp.php?id=344
work_keys_str_mv AT marianamayorquinruiz teleultrasonidooculardurantelapandemiadecovid19
AT anapbustamantevargas teleultrasonidooculardurantelapandemiadecovid19
AT catalinabecerrarevollo teleultrasonidooculardurantelapandemiadecovid19
AT carlosrioselizondo teleultrasonidooculardurantelapandemiadecovid19
AT davidberronesmedina teleultrasonidooculardurantelapandemiadecovid19
AT gerardomhernandezvalero teleultrasonidooculardurantelapandemiadecovid19
AT samuelpenaortiz teleultrasonidooculardurantelapandemiadecovid19
AT mariamcernichiaroespinosa teleultrasonidooculardurantelapandemiadecovid19