Teleultrasonido ocular durante la pandemia de COVID-19
Objective: To determine the concordance in ultrasound diagnoses made by an ophthalmologist who is not an expert in ocular ultrasound (ONE) guided virtually by an expert in ocular ultrasound (EUO1) and those made by a second expert in ocular ultrasound (EUO2). Method: Observational, cross-sectional s...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Jaypee Brothers Medical Publisher
2023-01-01
|
| Series: | Revista Mexicana de Oftalmología |
| Subjects: | |
| Online Access: | https://www.rmo.com.mx/frame_esp.php?id=344 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849717934994227200 |
|---|---|
| author | Mariana Mayorquín-Ruiz Ana P. Bustamante-Vargas Catalina Becerra-Revollo Carlos Ríos-Elizondo David Berrones-Medina Gerardo M. Hernández-Valero Samuel Peña-Ortiz Mariam Cernichiaro-Espinosa |
| author_facet | Mariana Mayorquín-Ruiz Ana P. Bustamante-Vargas Catalina Becerra-Revollo Carlos Ríos-Elizondo David Berrones-Medina Gerardo M. Hernández-Valero Samuel Peña-Ortiz Mariam Cernichiaro-Espinosa |
| author_sort | Mariana Mayorquín-Ruiz |
| collection | DOAJ |
| description | Objective: To determine the concordance in ultrasound diagnoses made by an ophthalmologist who is not an expert in ocular ultrasound (ONE) guided virtually by an expert in ocular ultrasound (EUO1) and those made by a second expert in ocular ultrasound (EUO2). Method: Observational, cross-sectional study. Patients referred to the ocular ultrasound service with media opacity were reviewed. The ONE performed the ultrasound study guided virtually by an EUO1. Subsequently, an EUO2 performed an ultrasound study on the same patient. Diagnoses and ultrasound findings of both were analyzed in a database. Results: We included 41 eyes of 24 patients referred to the ocular ultrasound service. The concordance between the ONE virtually guided by an EUO1 and the EUO2 was very high in the variables: ocular biometry, phakic state of the eye, presence of silicone in the vitreous cavity, presence of staphyloma, retinal and choroidal detachment. The variables with the least strength of correlation were: presence of posterior hyphema, description of optic nerve excavation and presence of hyaloid adhesion to the posterior pole. Conclusions: The high concordance between the ONE guided virtually by EUO1 and the EUO2, shows the possibility of developing mentoring and interconsultation through tele-ultrasound.
|
| format | Article |
| id | doaj-art-77b02bdcb32f485aa9334bc38aaacbc5 |
| institution | DOAJ |
| issn | 0187-4519 |
| language | English |
| publishDate | 2023-01-01 |
| publisher | Jaypee Brothers Medical Publisher |
| record_format | Article |
| series | Revista Mexicana de Oftalmología |
| spelling | doaj-art-77b02bdcb32f485aa9334bc38aaacbc52025-08-20T03:12:31ZengJaypee Brothers Medical PublisherRevista Mexicana de Oftalmología0187-45192023-01-0197610.24875/RMO.M25000260 Teleultrasonido ocular durante la pandemia de COVID-19Mariana Mayorquín-Ruiz0Ana P. Bustamante-Vargas1Catalina Becerra-Revollo2Carlos Ríos-Elizondo3David Berrones-Medina4Gerardo M. Hernández-Valero5Samuel Peña-Ortiz6Mariam Cernichiaro-Espinosa7Servicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Ultrasonido Ocular, Asociación para Evitar la Ceguera en México, Mexico City, MexicoServicio de Retina, Asociación para Evitar la Ceguera en México, Mexico City, MexicoObjective: To determine the concordance in ultrasound diagnoses made by an ophthalmologist who is not an expert in ocular ultrasound (ONE) guided virtually by an expert in ocular ultrasound (EUO1) and those made by a second expert in ocular ultrasound (EUO2). Method: Observational, cross-sectional study. Patients referred to the ocular ultrasound service with media opacity were reviewed. The ONE performed the ultrasound study guided virtually by an EUO1. Subsequently, an EUO2 performed an ultrasound study on the same patient. Diagnoses and ultrasound findings of both were analyzed in a database. Results: We included 41 eyes of 24 patients referred to the ocular ultrasound service. The concordance between the ONE virtually guided by an EUO1 and the EUO2 was very high in the variables: ocular biometry, phakic state of the eye, presence of silicone in the vitreous cavity, presence of staphyloma, retinal and choroidal detachment. The variables with the least strength of correlation were: presence of posterior hyphema, description of optic nerve excavation and presence of hyaloid adhesion to the posterior pole. Conclusions: The high concordance between the ONE guided virtually by EUO1 and the EUO2, shows the possibility of developing mentoring and interconsultation through tele-ultrasound. https://www.rmo.com.mx/frame_esp.php?id=344Ocular teleultrasound. Telemedicine. Ultrasound imaging. |
| spellingShingle | Mariana Mayorquín-Ruiz Ana P. Bustamante-Vargas Catalina Becerra-Revollo Carlos Ríos-Elizondo David Berrones-Medina Gerardo M. Hernández-Valero Samuel Peña-Ortiz Mariam Cernichiaro-Espinosa Teleultrasonido ocular durante la pandemia de COVID-19 Revista Mexicana de Oftalmología Ocular teleultrasound. Telemedicine. Ultrasound imaging. |
| title | Teleultrasonido ocular durante la pandemia de COVID-19 |
| title_full | Teleultrasonido ocular durante la pandemia de COVID-19 |
| title_fullStr | Teleultrasonido ocular durante la pandemia de COVID-19 |
| title_full_unstemmed | Teleultrasonido ocular durante la pandemia de COVID-19 |
| title_short | Teleultrasonido ocular durante la pandemia de COVID-19 |
| title_sort | teleultrasonido ocular durante la pandemia de covid 19 |
| topic | Ocular teleultrasound. Telemedicine. Ultrasound imaging. |
| url | https://www.rmo.com.mx/frame_esp.php?id=344 |
| work_keys_str_mv | AT marianamayorquinruiz teleultrasonidooculardurantelapandemiadecovid19 AT anapbustamantevargas teleultrasonidooculardurantelapandemiadecovid19 AT catalinabecerrarevollo teleultrasonidooculardurantelapandemiadecovid19 AT carlosrioselizondo teleultrasonidooculardurantelapandemiadecovid19 AT davidberronesmedina teleultrasonidooculardurantelapandemiadecovid19 AT gerardomhernandezvalero teleultrasonidooculardurantelapandemiadecovid19 AT samuelpenaortiz teleultrasonidooculardurantelapandemiadecovid19 AT mariamcernichiaroespinosa teleultrasonidooculardurantelapandemiadecovid19 |