Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.

<h4>Background</h4>HIV viral load (VL) testing is the gold standard for antiretroviral treatment monitoring, but many barriers exist to VL testing in resource-limited settings, including storage and transport limitations for whole blood and plasma. Data from various studies indicate that...

Full description

Saved in:
Bibliographic Details
Main Authors: Kimberly Bonner, Reed A Siemieniuk, Andrew Boozary, Teri Roberts, Emmanuel Fajardo, Jennifer Cohn
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2014-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0113813
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849254249267986432
author Kimberly Bonner
Reed A Siemieniuk
Andrew Boozary
Teri Roberts
Emmanuel Fajardo
Jennifer Cohn
author_facet Kimberly Bonner
Reed A Siemieniuk
Andrew Boozary
Teri Roberts
Emmanuel Fajardo
Jennifer Cohn
author_sort Kimberly Bonner
collection DOAJ
description <h4>Background</h4>HIV viral load (VL) testing is the gold standard for antiretroviral treatment monitoring, but many barriers exist to VL testing in resource-limited settings, including storage and transport limitations for whole blood and plasma. Data from various studies indicate that HIV RNA is stable beyond current recommendations. We conducted a systematic review to assess stability data of HIV RNA in whole blood and plasma across times and temperatures.<h4>Methods and findings</h4>Using a pre-defined protocol, five databases were searched for studies where blood samples from HIV patients were stored at time and temperature points that exceeded manufacturer recommendations. RNA stability, the primary outcome, was measured by the difference in means compared to samples stored within established thresholds. RNA stability was defined as ≤0.5 log degradation. The search identified 10,716 titles, of which nine full-text articles were included for review. HIV RNA maintained stability in EDTA whole blood and plasma at all measured time points up to 168 hours when stored at 4°C, while stability was detected at 72 hours (95% confidence) in whole blood at 25°C, with data points before and beyond 72 hours suggesting stability but not reaching statistical significance. For EDTA plasma stored at 30°C, stability was maintained up to 48 hours (95% confidence), with OLS linear regression estimates up to 127 hours, suggesting stability. Overall, quality of studies was moderate. Limitations included small sample sizes, few studies meeting inclusion criteria, and no studies examining RNA stability in low viremia (<3,000 copies/mL) environments.<h4>Conclusions</h4>Whole blood and plasma samples in EDTA may remain stable under conditions exceeding current manufacturer recommendations for HIV VL testing. However, given the limited number of studies addressing this question, especially at low levels of viremia, additional evaluations on HIV RNA stability in EDTA tubes and PPT in field conditions are needed.
format Article
id doaj-art-75bdb6cd6b35437d8a40abef9d489c66
institution Kabale University
issn 1932-6203
language English
publishDate 2014-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj-art-75bdb6cd6b35437d8a40abef9d489c662025-08-20T03:56:05ZengPublic Library of Science (PLoS)PLoS ONE1932-62032014-01-01912e11381310.1371/journal.pone.0113813Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.Kimberly BonnerReed A SiemieniukAndrew BoozaryTeri RobertsEmmanuel FajardoJennifer Cohn<h4>Background</h4>HIV viral load (VL) testing is the gold standard for antiretroviral treatment monitoring, but many barriers exist to VL testing in resource-limited settings, including storage and transport limitations for whole blood and plasma. Data from various studies indicate that HIV RNA is stable beyond current recommendations. We conducted a systematic review to assess stability data of HIV RNA in whole blood and plasma across times and temperatures.<h4>Methods and findings</h4>Using a pre-defined protocol, five databases were searched for studies where blood samples from HIV patients were stored at time and temperature points that exceeded manufacturer recommendations. RNA stability, the primary outcome, was measured by the difference in means compared to samples stored within established thresholds. RNA stability was defined as ≤0.5 log degradation. The search identified 10,716 titles, of which nine full-text articles were included for review. HIV RNA maintained stability in EDTA whole blood and plasma at all measured time points up to 168 hours when stored at 4°C, while stability was detected at 72 hours (95% confidence) in whole blood at 25°C, with data points before and beyond 72 hours suggesting stability but not reaching statistical significance. For EDTA plasma stored at 30°C, stability was maintained up to 48 hours (95% confidence), with OLS linear regression estimates up to 127 hours, suggesting stability. Overall, quality of studies was moderate. Limitations included small sample sizes, few studies meeting inclusion criteria, and no studies examining RNA stability in low viremia (<3,000 copies/mL) environments.<h4>Conclusions</h4>Whole blood and plasma samples in EDTA may remain stable under conditions exceeding current manufacturer recommendations for HIV VL testing. However, given the limited number of studies addressing this question, especially at low levels of viremia, additional evaluations on HIV RNA stability in EDTA tubes and PPT in field conditions are needed.https://doi.org/10.1371/journal.pone.0113813
spellingShingle Kimberly Bonner
Reed A Siemieniuk
Andrew Boozary
Teri Roberts
Emmanuel Fajardo
Jennifer Cohn
Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.
PLoS ONE
title Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.
title_full Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.
title_fullStr Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.
title_full_unstemmed Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.
title_short Expanding access to HIV viral load testing: a systematic review of RNA stability in EDTA tubes and PPT beyond current time and temperature thresholds.
title_sort expanding access to hiv viral load testing a systematic review of rna stability in edta tubes and ppt beyond current time and temperature thresholds
url https://doi.org/10.1371/journal.pone.0113813
work_keys_str_mv AT kimberlybonner expandingaccesstohivviralloadtestingasystematicreviewofrnastabilityinedtatubesandpptbeyondcurrenttimeandtemperaturethresholds
AT reedasiemieniuk expandingaccesstohivviralloadtestingasystematicreviewofrnastabilityinedtatubesandpptbeyondcurrenttimeandtemperaturethresholds
AT andrewboozary expandingaccesstohivviralloadtestingasystematicreviewofrnastabilityinedtatubesandpptbeyondcurrenttimeandtemperaturethresholds
AT teriroberts expandingaccesstohivviralloadtestingasystematicreviewofrnastabilityinedtatubesandpptbeyondcurrenttimeandtemperaturethresholds
AT emmanuelfajardo expandingaccesstohivviralloadtestingasystematicreviewofrnastabilityinedtatubesandpptbeyondcurrenttimeandtemperaturethresholds
AT jennifercohn expandingaccesstohivviralloadtestingasystematicreviewofrnastabilityinedtatubesandpptbeyondcurrenttimeandtemperaturethresholds