Fixed Bed Column Adsorption System for the Removal of 2,4-Dichlorophenoxyacetic Acid Herbicide from an Aqueous Solution

The intensive use of 2,4-dichlorophenoxyacetic acid (2,4-D) herbicide has resulted in the presence of its residues in the environment, which leads to contamination of surface and groundwater. In this study, a fixed-bed column experiment was conducted for the removal of 2,4-D from an aqueous solution...

Full description

Saved in:
Bibliographic Details
Main Authors: Yalemtsehay Debebe, Zemene Worku, Esayas Alemayehu
Format: Article
Language:English
Published: Wiley 2024-01-01
Series:Journal of Engineering
Online Access:http://dx.doi.org/10.1155/2024/1629004
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850220641260666880
author Yalemtsehay Debebe
Zemene Worku
Esayas Alemayehu
author_facet Yalemtsehay Debebe
Zemene Worku
Esayas Alemayehu
author_sort Yalemtsehay Debebe
collection DOAJ
description The intensive use of 2,4-dichlorophenoxyacetic acid (2,4-D) herbicide has resulted in the presence of its residues in the environment, which leads to contamination of surface and groundwater. In this study, a fixed-bed column experiment was conducted for the removal of 2,4-D from an aqueous solution using termite mound soil (TMS). Scanning electron microscopy (SEM), Fourier transform infrared (FTIR), atomic absorption spectrometry (AAS), and Brunauer–Emmett–Teller (BET) techniques were used to characterize the adsorbent. The effect of significant variables, such as the initial 2,4-D concentration (50 mg/L and 75 mg/L), flow rate (2.5 ml/min and 5 ml/min), solution pH (2, 4, and 6), and bed height (3, 6, and 9 cm), on the breakthrough characteristics of the adsorption system was assessed. In addition, the Thomas and Yoon–Nelson models were applied to predict the breakthrough curves and to determine the characteristic parameters of the column that are useful for process design. The findings showed that at a lower pH (2), a lower flow rate (2.5 ml/min), a lower 2,4-D concentration (50 mg/L), a higher bed depth (9 cm), and 840 min breakthrough time, a higher removal percentage (80.2%) of 2,4-D was achieved. The experimental data were in good agreement with the Thomas and Yoon–Nelson models. For the Yoon–Nelson model, the rate constant increased with an increase in the flow rate, initial ion concentration, and bed height. The time required for a 50% breakthrough decreased with an increase in the flow rate, bed height, and initial ion concentration. For the Thomas model, the rate constant increased with an increase in the flow rate but decreased with an increase in bed height and initial concentration. Overall, the study showed that termite mound soil in a fixed-bed column adsorption system presents an excellent potential for removing 2,4-D from aqueous solutions.
format Article
id doaj-art-75ab3fe759b547eea3fbcb2e4602be01
institution OA Journals
issn 2314-4912
language English
publishDate 2024-01-01
publisher Wiley
record_format Article
series Journal of Engineering
spelling doaj-art-75ab3fe759b547eea3fbcb2e4602be012025-08-20T02:07:01ZengWileyJournal of Engineering2314-49122024-01-01202410.1155/2024/1629004Fixed Bed Column Adsorption System for the Removal of 2,4-Dichlorophenoxyacetic Acid Herbicide from an Aqueous SolutionYalemtsehay Debebe0Zemene Worku1Esayas Alemayehu2Addis Ababa Science and Technology UniversityAddis Ababa Science and Technology UniversityJimma Institute of TechnologyThe intensive use of 2,4-dichlorophenoxyacetic acid (2,4-D) herbicide has resulted in the presence of its residues in the environment, which leads to contamination of surface and groundwater. In this study, a fixed-bed column experiment was conducted for the removal of 2,4-D from an aqueous solution using termite mound soil (TMS). Scanning electron microscopy (SEM), Fourier transform infrared (FTIR), atomic absorption spectrometry (AAS), and Brunauer–Emmett–Teller (BET) techniques were used to characterize the adsorbent. The effect of significant variables, such as the initial 2,4-D concentration (50 mg/L and 75 mg/L), flow rate (2.5 ml/min and 5 ml/min), solution pH (2, 4, and 6), and bed height (3, 6, and 9 cm), on the breakthrough characteristics of the adsorption system was assessed. In addition, the Thomas and Yoon–Nelson models were applied to predict the breakthrough curves and to determine the characteristic parameters of the column that are useful for process design. The findings showed that at a lower pH (2), a lower flow rate (2.5 ml/min), a lower 2,4-D concentration (50 mg/L), a higher bed depth (9 cm), and 840 min breakthrough time, a higher removal percentage (80.2%) of 2,4-D was achieved. The experimental data were in good agreement with the Thomas and Yoon–Nelson models. For the Yoon–Nelson model, the rate constant increased with an increase in the flow rate, initial ion concentration, and bed height. The time required for a 50% breakthrough decreased with an increase in the flow rate, bed height, and initial ion concentration. For the Thomas model, the rate constant increased with an increase in the flow rate but decreased with an increase in bed height and initial concentration. Overall, the study showed that termite mound soil in a fixed-bed column adsorption system presents an excellent potential for removing 2,4-D from aqueous solutions.http://dx.doi.org/10.1155/2024/1629004
spellingShingle Yalemtsehay Debebe
Zemene Worku
Esayas Alemayehu
Fixed Bed Column Adsorption System for the Removal of 2,4-Dichlorophenoxyacetic Acid Herbicide from an Aqueous Solution
Journal of Engineering
title Fixed Bed Column Adsorption System for the Removal of 2,4-Dichlorophenoxyacetic Acid Herbicide from an Aqueous Solution
title_full Fixed Bed Column Adsorption System for the Removal of 2,4-Dichlorophenoxyacetic Acid Herbicide from an Aqueous Solution
title_fullStr Fixed Bed Column Adsorption System for the Removal of 2,4-Dichlorophenoxyacetic Acid Herbicide from an Aqueous Solution
title_full_unstemmed Fixed Bed Column Adsorption System for the Removal of 2,4-Dichlorophenoxyacetic Acid Herbicide from an Aqueous Solution
title_short Fixed Bed Column Adsorption System for the Removal of 2,4-Dichlorophenoxyacetic Acid Herbicide from an Aqueous Solution
title_sort fixed bed column adsorption system for the removal of 2 4 dichlorophenoxyacetic acid herbicide from an aqueous solution
url http://dx.doi.org/10.1155/2024/1629004
work_keys_str_mv AT yalemtsehaydebebe fixedbedcolumnadsorptionsystemfortheremovalof24dichlorophenoxyaceticacidherbicidefromanaqueoussolution
AT zemeneworku fixedbedcolumnadsorptionsystemfortheremovalof24dichlorophenoxyaceticacidherbicidefromanaqueoussolution
AT esayasalemayehu fixedbedcolumnadsorptionsystemfortheremovalof24dichlorophenoxyaceticacidherbicidefromanaqueoussolution