Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations
This paper proposes an inaccuracy mitigation measure to reduce the error associated with distribution line parameters identification. Additionally, it introduces the concept of positive sequence quantities for determining the line resistance, reactive inductance, and shunt admittance. The positive s...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2018-01-01
|
| Series: | Journal of Electrical and Computer Engineering |
| Online Access: | http://dx.doi.org/10.1155/2018/8719670 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849409595774074880 |
|---|---|
| author | Mustafa M. Al Khabbaz Mohamed A. Abido |
| author_facet | Mustafa M. Al Khabbaz Mohamed A. Abido |
| author_sort | Mustafa M. Al Khabbaz |
| collection | DOAJ |
| description | This paper proposes an inaccuracy mitigation measure to reduce the error associated with distribution line parameters identification. Additionally, it introduces the concept of positive sequence quantities for determining the line resistance, reactive inductance, and shunt admittance. The positive sequence-based analysis is required for asymmetrical related studies such as unbalanced fault analysis. The paper, also, includes the consideration of noisy distribution networks. It compares the performance of three line parameters identification techniques by using different statistical measures. A total of 12,960 different case studies are simulated and analyzed under six main loading scenarios and four categories with changing line parameters. The line parameters are calculated online using voltage and current signals obtained from phasor measurement units (PMUs) placed at the line two terminals. Finally, the study outcomes and the associated recommendations have been summarized for future works considerations. |
| format | Article |
| id | doaj-art-7585d2b69ad846abb9f45ea958209aa3 |
| institution | Kabale University |
| issn | 2090-0147 2090-0155 |
| language | English |
| publishDate | 2018-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | Journal of Electrical and Computer Engineering |
| spelling | doaj-art-7585d2b69ad846abb9f45ea958209aa32025-08-20T03:35:27ZengWileyJournal of Electrical and Computer Engineering2090-01472090-01552018-01-01201810.1155/2018/87196708719670Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise ConsiderationsMustafa M. Al Khabbaz0Mohamed A. Abido1Facilities Planning Department, Saudi Arabian Oil Company (Saudi Aramco), Dhahran 31311, Saudi ArabiaElectrical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi ArabiaThis paper proposes an inaccuracy mitigation measure to reduce the error associated with distribution line parameters identification. Additionally, it introduces the concept of positive sequence quantities for determining the line resistance, reactive inductance, and shunt admittance. The positive sequence-based analysis is required for asymmetrical related studies such as unbalanced fault analysis. The paper, also, includes the consideration of noisy distribution networks. It compares the performance of three line parameters identification techniques by using different statistical measures. A total of 12,960 different case studies are simulated and analyzed under six main loading scenarios and four categories with changing line parameters. The line parameters are calculated online using voltage and current signals obtained from phasor measurement units (PMUs) placed at the line two terminals. Finally, the study outcomes and the associated recommendations have been summarized for future works considerations.http://dx.doi.org/10.1155/2018/8719670 |
| spellingShingle | Mustafa M. Al Khabbaz Mohamed A. Abido Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations Journal of Electrical and Computer Engineering |
| title | Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations |
| title_full | Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations |
| title_fullStr | Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations |
| title_full_unstemmed | Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations |
| title_short | Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations |
| title_sort | online identification of distribution line parameters by pmus under accuracy positive sequence and noise considerations |
| url | http://dx.doi.org/10.1155/2018/8719670 |
| work_keys_str_mv | AT mustafamalkhabbaz onlineidentificationofdistributionlineparametersbypmusunderaccuracypositivesequenceandnoiseconsiderations AT mohamedaabido onlineidentificationofdistributionlineparametersbypmusunderaccuracypositivesequenceandnoiseconsiderations |