Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations

This paper proposes an inaccuracy mitigation measure to reduce the error associated with distribution line parameters identification. Additionally, it introduces the concept of positive sequence quantities for determining the line resistance, reactive inductance, and shunt admittance. The positive s...

Full description

Saved in:
Bibliographic Details
Main Authors: Mustafa M. Al Khabbaz, Mohamed A. Abido
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Journal of Electrical and Computer Engineering
Online Access:http://dx.doi.org/10.1155/2018/8719670
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849409595774074880
author Mustafa M. Al Khabbaz
Mohamed A. Abido
author_facet Mustafa M. Al Khabbaz
Mohamed A. Abido
author_sort Mustafa M. Al Khabbaz
collection DOAJ
description This paper proposes an inaccuracy mitigation measure to reduce the error associated with distribution line parameters identification. Additionally, it introduces the concept of positive sequence quantities for determining the line resistance, reactive inductance, and shunt admittance. The positive sequence-based analysis is required for asymmetrical related studies such as unbalanced fault analysis. The paper, also, includes the consideration of noisy distribution networks. It compares the performance of three line parameters identification techniques by using different statistical measures. A total of 12,960 different case studies are simulated and analyzed under six main loading scenarios and four categories with changing line parameters. The line parameters are calculated online using voltage and current signals obtained from phasor measurement units (PMUs) placed at the line two terminals. Finally, the study outcomes and the associated recommendations have been summarized for future works considerations.
format Article
id doaj-art-7585d2b69ad846abb9f45ea958209aa3
institution Kabale University
issn 2090-0147
2090-0155
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Journal of Electrical and Computer Engineering
spelling doaj-art-7585d2b69ad846abb9f45ea958209aa32025-08-20T03:35:27ZengWileyJournal of Electrical and Computer Engineering2090-01472090-01552018-01-01201810.1155/2018/87196708719670Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise ConsiderationsMustafa M. Al Khabbaz0Mohamed A. Abido1Facilities Planning Department, Saudi Arabian Oil Company (Saudi Aramco), Dhahran 31311, Saudi ArabiaElectrical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi ArabiaThis paper proposes an inaccuracy mitigation measure to reduce the error associated with distribution line parameters identification. Additionally, it introduces the concept of positive sequence quantities for determining the line resistance, reactive inductance, and shunt admittance. The positive sequence-based analysis is required for asymmetrical related studies such as unbalanced fault analysis. The paper, also, includes the consideration of noisy distribution networks. It compares the performance of three line parameters identification techniques by using different statistical measures. A total of 12,960 different case studies are simulated and analyzed under six main loading scenarios and four categories with changing line parameters. The line parameters are calculated online using voltage and current signals obtained from phasor measurement units (PMUs) placed at the line two terminals. Finally, the study outcomes and the associated recommendations have been summarized for future works considerations.http://dx.doi.org/10.1155/2018/8719670
spellingShingle Mustafa M. Al Khabbaz
Mohamed A. Abido
Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations
Journal of Electrical and Computer Engineering
title Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations
title_full Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations
title_fullStr Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations
title_full_unstemmed Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations
title_short Online Identification of Distribution Line Parameters by PMUs under Accuracy, Positive Sequence, and Noise Considerations
title_sort online identification of distribution line parameters by pmus under accuracy positive sequence and noise considerations
url http://dx.doi.org/10.1155/2018/8719670
work_keys_str_mv AT mustafamalkhabbaz onlineidentificationofdistributionlineparametersbypmusunderaccuracypositivesequenceandnoiseconsiderations
AT mohamedaabido onlineidentificationofdistributionlineparametersbypmusunderaccuracypositivesequenceandnoiseconsiderations