Green trapping intra tube flux extraction device using polymethyl methacrylate for organochlorine pesticide analysis by gas chromatography-mass spectrometry

In chemical analysis, sample preparation is the most time-consuming and error-prone step. Available routine methods such as SPE and SPME are usually laborious, expensive, and fragile. For instance, the highly sensitive SPME fibers can break with even a tiny error, rendering them unusable. In this pa...

Full description

Saved in:
Bibliographic Details
Main Authors: Desirée Marianne Sales Silveira, Jhonatan Bispo de Oliveira, Ildefonso Binatti, Emerson Fernandes Pedroso, Patrícia Santiago de Oliveira Patricio, Patterson Patricio de Souza
Format: Article
Language:English
Published: Elsevier 2025-06-01
Series:Green Analytical Chemistry
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2772577425000710
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850143525662883840
author Desirée Marianne Sales Silveira
Jhonatan Bispo de Oliveira
Ildefonso Binatti
Emerson Fernandes Pedroso
Patrícia Santiago de Oliveira Patricio
Patterson Patricio de Souza
author_facet Desirée Marianne Sales Silveira
Jhonatan Bispo de Oliveira
Ildefonso Binatti
Emerson Fernandes Pedroso
Patrícia Santiago de Oliveira Patricio
Patterson Patricio de Souza
author_sort Desirée Marianne Sales Silveira
collection DOAJ
description In chemical analysis, sample preparation is the most time-consuming and error-prone step. Available routine methods such as SPE and SPME are usually laborious, expensive, and fragile. For instance, the highly sensitive SPME fibers can break with even a tiny error, rendering them unusable. In this paper, the use of Poly(methyl methacrylate) (PMMA) as the extraction phase in Intra Tube Flux extraction (IT-FEx-SPME) is presented as a one-step, environmentally friendly, and solvent-free method of aqueous sample preparation for gas chromatography. After the extraction of the analytes, the device is inserted into the gas chromatograph (GC) injector for thermal desorption and chromatographic separation. Different molar masses of the PMMA extraction phase for coating the device were also investigated, specifically 120,000 g mol−1 and 350,000 g mol−1; the denser one was more thermally stable in the long term. The method was optimized and validated for analyzing five organochlorine pesticides - heptachlor, aldrin, heptachlor epoxide, endosulfan, and dieldrin. LOD from 0.21 to 1.63 ng mL−1 and LOQ from 0.92 to 7.22 ng mL−1 were achieved. Repeatability within one day (n = 5) resulted in RSD values of 6.09 % to 23.28 %. Inter-day reproducibility (n = 10) showed RSD values ranging from 12.94 % to 19.33 %. The recovery values ranged from 93.07 % to 100.32 %. The method offers a feasible, cost-effective, rapid, green, and safe alternative for the routine analysis of organochlorine pesticides in aqueous samples using GC.
format Article
id doaj-art-7473282546d14bf8bcdf372e65920b2d
institution OA Journals
issn 2772-5774
language English
publishDate 2025-06-01
publisher Elsevier
record_format Article
series Green Analytical Chemistry
spelling doaj-art-7473282546d14bf8bcdf372e65920b2d2025-08-20T02:28:41ZengElsevierGreen Analytical Chemistry2772-57742025-06-011310027510.1016/j.greeac.2025.100275Green trapping intra tube flux extraction device using polymethyl methacrylate for organochlorine pesticide analysis by gas chromatography-mass spectrometryDesirée Marianne Sales Silveira0Jhonatan Bispo de Oliveira1Ildefonso Binatti2Emerson Fernandes Pedroso3Patrícia Santiago de Oliveira Patricio4Patterson Patricio de Souza5Department of Chemistry, Centro Federal de Educação Tecnológica de Minas Gerais, Av. Amazonas 5253, 30421-169, BH-MG, BrazilDepartment of Chemistry, Centro Federal de Educação Tecnológica de Minas Gerais, Av. Amazonas 5253, 30421-169, BH-MG, BrazilDepartment of Chemistry, Centro Federal de Educação Tecnológica de Minas Gerais, Av. Amazonas 5253, 30421-169, BH-MG, BrazilDepartment of Chemistry, Centro Federal de Educação Tecnológica de Minas Gerais, Av. Amazonas 5253, 30421-169, BH-MG, BrazilDepartment of Chemistry, Centro Federal de Educação Tecnológica de Minas Gerais, Av. Amazonas 5253, 30421-169, BH-MG, BrazilCorresponding author.; Department of Chemistry, Centro Federal de Educação Tecnológica de Minas Gerais, Av. Amazonas 5253, 30421-169, BH-MG, BrazilIn chemical analysis, sample preparation is the most time-consuming and error-prone step. Available routine methods such as SPE and SPME are usually laborious, expensive, and fragile. For instance, the highly sensitive SPME fibers can break with even a tiny error, rendering them unusable. In this paper, the use of Poly(methyl methacrylate) (PMMA) as the extraction phase in Intra Tube Flux extraction (IT-FEx-SPME) is presented as a one-step, environmentally friendly, and solvent-free method of aqueous sample preparation for gas chromatography. After the extraction of the analytes, the device is inserted into the gas chromatograph (GC) injector for thermal desorption and chromatographic separation. Different molar masses of the PMMA extraction phase for coating the device were also investigated, specifically 120,000 g mol−1 and 350,000 g mol−1; the denser one was more thermally stable in the long term. The method was optimized and validated for analyzing five organochlorine pesticides - heptachlor, aldrin, heptachlor epoxide, endosulfan, and dieldrin. LOD from 0.21 to 1.63 ng mL−1 and LOQ from 0.92 to 7.22 ng mL−1 were achieved. Repeatability within one day (n = 5) resulted in RSD values of 6.09 % to 23.28 %. Inter-day reproducibility (n = 10) showed RSD values ranging from 12.94 % to 19.33 %. The recovery values ranged from 93.07 % to 100.32 %. The method offers a feasible, cost-effective, rapid, green, and safe alternative for the routine analysis of organochlorine pesticides in aqueous samples using GC.http://www.sciencedirect.com/science/article/pii/S2772577425000710IT-FEx-SPMEPMMASample preparationOrganochlorine pesticidesGC/MS
spellingShingle Desirée Marianne Sales Silveira
Jhonatan Bispo de Oliveira
Ildefonso Binatti
Emerson Fernandes Pedroso
Patrícia Santiago de Oliveira Patricio
Patterson Patricio de Souza
Green trapping intra tube flux extraction device using polymethyl methacrylate for organochlorine pesticide analysis by gas chromatography-mass spectrometry
Green Analytical Chemistry
IT-FEx-SPME
PMMA
Sample preparation
Organochlorine pesticides
GC/MS
title Green trapping intra tube flux extraction device using polymethyl methacrylate for organochlorine pesticide analysis by gas chromatography-mass spectrometry
title_full Green trapping intra tube flux extraction device using polymethyl methacrylate for organochlorine pesticide analysis by gas chromatography-mass spectrometry
title_fullStr Green trapping intra tube flux extraction device using polymethyl methacrylate for organochlorine pesticide analysis by gas chromatography-mass spectrometry
title_full_unstemmed Green trapping intra tube flux extraction device using polymethyl methacrylate for organochlorine pesticide analysis by gas chromatography-mass spectrometry
title_short Green trapping intra tube flux extraction device using polymethyl methacrylate for organochlorine pesticide analysis by gas chromatography-mass spectrometry
title_sort green trapping intra tube flux extraction device using polymethyl methacrylate for organochlorine pesticide analysis by gas chromatography mass spectrometry
topic IT-FEx-SPME
PMMA
Sample preparation
Organochlorine pesticides
GC/MS
url http://www.sciencedirect.com/science/article/pii/S2772577425000710
work_keys_str_mv AT desireemariannesalessilveira greentrappingintratubefluxextractiondeviceusingpolymethylmethacrylatefororganochlorinepesticideanalysisbygaschromatographymassspectrometry
AT jhonatanbispodeoliveira greentrappingintratubefluxextractiondeviceusingpolymethylmethacrylatefororganochlorinepesticideanalysisbygaschromatographymassspectrometry
AT ildefonsobinatti greentrappingintratubefluxextractiondeviceusingpolymethylmethacrylatefororganochlorinepesticideanalysisbygaschromatographymassspectrometry
AT emersonfernandespedroso greentrappingintratubefluxextractiondeviceusingpolymethylmethacrylatefororganochlorinepesticideanalysisbygaschromatographymassspectrometry
AT patriciasantiagodeoliveirapatricio greentrappingintratubefluxextractiondeviceusingpolymethylmethacrylatefororganochlorinepesticideanalysisbygaschromatographymassspectrometry
AT pattersonpatriciodesouza greentrappingintratubefluxextractiondeviceusingpolymethylmethacrylatefororganochlorinepesticideanalysisbygaschromatographymassspectrometry