DPOAE Responses in Humans and Ear Models: Can a Single-Loudspeaker Approach Match the Two-Loudspeaker Technique?

When a dual-tone frequency stimulus (<inline-formula> <tex-math notation="LaTeX">$f_{1}$ </tex-math></inline-formula> and <inline-formula> <tex-math notation="LaTeX">$f_{2}$ </tex-math></inline-formula>) is presented to the ear, the...

Full description

Saved in:
Bibliographic Details
Main Authors: Irwansyah, Sho Otsuka, Seiji Nakagawa
Format: Article
Language:English
Published: IEEE 2025-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/11036177/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850114130860572672
author Irwansyah
Sho Otsuka
Seiji Nakagawa
author_facet Irwansyah
Sho Otsuka
Seiji Nakagawa
author_sort Irwansyah
collection DOAJ
description When a dual-tone frequency stimulus (<inline-formula> <tex-math notation="LaTeX">$f_{1}$ </tex-math></inline-formula> and <inline-formula> <tex-math notation="LaTeX">$f_{2}$ </tex-math></inline-formula>) is presented to the ear, the cochlea responds by generating a tone at <inline-formula> <tex-math notation="LaTeX">$2 f_{1}-f_{2}$ </tex-math></inline-formula>, known as the distortion product otoacoustic emission (DPOAE), useful for assessing cochlear health. Typically, to measure emissions from one ear, tones at <inline-formula> <tex-math notation="LaTeX">$f_{1}$ </tex-math></inline-formula> and <inline-formula> <tex-math notation="LaTeX">$f_{2}$ </tex-math></inline-formula> are generated by two separate loudspeakers and delivered through tubing to a single probe in most clinical DPOAE devices. Using a single loudspeaker, however, introduces cubic intermodulation distortion (IMD) at <inline-formula> <tex-math notation="LaTeX">$2 f_{1}-f_{2}$ </tex-math></inline-formula>, which interferes with the DPOAE signal, making accurate measurements difficult. In this study, to enable DPOAE measurement using only one loudspeaker, we designed a three-tone stimulus. The third tone was adjusted in phase and amplitude to destructively interfere with the IMD at <inline-formula> <tex-math notation="LaTeX">$2 f_{1}-f_{2}$ </tex-math></inline-formula>, effectively canceling it. Using an IEC 60318&#x2013;4 ear simulator, we optimized the third tone parameters and then measured DPOAEs with single- and two-loudspeaker setups. DPOAEs from 54 ears were measured at frequencies from 1&#x2013;8 kHz using an ER-10B+ DPOAE microphone system, with an <inline-formula> <tex-math notation="LaTeX">$f_{2}/f_{1}$ </tex-math></inline-formula> ratio of 1.22 and stimulus levels of <inline-formula> <tex-math notation="LaTeX">$65/55$ </tex-math></inline-formula> dB SPL (<inline-formula> <tex-math notation="LaTeX">$L_{1}/L_{2}$ </tex-math></inline-formula>). Bland-Altman analysis, with limits of agreement (LoA), was performed to assess whether the method sufficiently agreed with the standard DPOAE technique. Additionally, 10 silicone ear models, created from 3D scans of real human outer ears, were used to evaluate residual IMD that cannot be measured in humans due to the presence of DPOAEs. These models accounted for the anatomical effects of the ear canal shape, providing an objective, realistic assessment of cancellation performance.
format Article
id doaj-art-745f8de7f65449f2987e806bf5963fe9
institution OA Journals
issn 2169-3536
language English
publishDate 2025-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj-art-745f8de7f65449f2987e806bf5963fe92025-08-20T02:36:59ZengIEEEIEEE Access2169-35362025-01-011310309510310810.1109/ACCESS.2025.357947511036177DPOAE Responses in Humans and Ear Models: Can a Single-Loudspeaker Approach Match the Two-Loudspeaker Technique? Irwansyah0https://orcid.org/0000-0001-5702-3279Sho Otsuka1Seiji Nakagawa2Center for Frontier Medical Engineering, Chiba University, Chiba, JapanCenter for Frontier Medical Engineering, Chiba University, Chiba, JapanCenter for Frontier Medical Engineering, Chiba University, Chiba, JapanWhen a dual-tone frequency stimulus (<inline-formula> <tex-math notation="LaTeX">$f_{1}$ </tex-math></inline-formula> and <inline-formula> <tex-math notation="LaTeX">$f_{2}$ </tex-math></inline-formula>) is presented to the ear, the cochlea responds by generating a tone at <inline-formula> <tex-math notation="LaTeX">$2 f_{1}-f_{2}$ </tex-math></inline-formula>, known as the distortion product otoacoustic emission (DPOAE), useful for assessing cochlear health. Typically, to measure emissions from one ear, tones at <inline-formula> <tex-math notation="LaTeX">$f_{1}$ </tex-math></inline-formula> and <inline-formula> <tex-math notation="LaTeX">$f_{2}$ </tex-math></inline-formula> are generated by two separate loudspeakers and delivered through tubing to a single probe in most clinical DPOAE devices. Using a single loudspeaker, however, introduces cubic intermodulation distortion (IMD) at <inline-formula> <tex-math notation="LaTeX">$2 f_{1}-f_{2}$ </tex-math></inline-formula>, which interferes with the DPOAE signal, making accurate measurements difficult. In this study, to enable DPOAE measurement using only one loudspeaker, we designed a three-tone stimulus. The third tone was adjusted in phase and amplitude to destructively interfere with the IMD at <inline-formula> <tex-math notation="LaTeX">$2 f_{1}-f_{2}$ </tex-math></inline-formula>, effectively canceling it. Using an IEC 60318&#x2013;4 ear simulator, we optimized the third tone parameters and then measured DPOAEs with single- and two-loudspeaker setups. DPOAEs from 54 ears were measured at frequencies from 1&#x2013;8 kHz using an ER-10B+ DPOAE microphone system, with an <inline-formula> <tex-math notation="LaTeX">$f_{2}/f_{1}$ </tex-math></inline-formula> ratio of 1.22 and stimulus levels of <inline-formula> <tex-math notation="LaTeX">$65/55$ </tex-math></inline-formula> dB SPL (<inline-formula> <tex-math notation="LaTeX">$L_{1}/L_{2}$ </tex-math></inline-formula>). Bland-Altman analysis, with limits of agreement (LoA), was performed to assess whether the method sufficiently agreed with the standard DPOAE technique. Additionally, 10 silicone ear models, created from 3D scans of real human outer ears, were used to evaluate residual IMD that cannot be measured in humans due to the presence of DPOAEs. These models accounted for the anatomical effects of the ear canal shape, providing an objective, realistic assessment of cancellation performance.https://ieeexplore.ieee.org/document/11036177/DPOAEintermodulation distortionsingle-loudspeaker setupsilicone ear models
spellingShingle Irwansyah
Sho Otsuka
Seiji Nakagawa
DPOAE Responses in Humans and Ear Models: Can a Single-Loudspeaker Approach Match the Two-Loudspeaker Technique?
IEEE Access
DPOAE
intermodulation distortion
single-loudspeaker setup
silicone ear models
title DPOAE Responses in Humans and Ear Models: Can a Single-Loudspeaker Approach Match the Two-Loudspeaker Technique?
title_full DPOAE Responses in Humans and Ear Models: Can a Single-Loudspeaker Approach Match the Two-Loudspeaker Technique?
title_fullStr DPOAE Responses in Humans and Ear Models: Can a Single-Loudspeaker Approach Match the Two-Loudspeaker Technique?
title_full_unstemmed DPOAE Responses in Humans and Ear Models: Can a Single-Loudspeaker Approach Match the Two-Loudspeaker Technique?
title_short DPOAE Responses in Humans and Ear Models: Can a Single-Loudspeaker Approach Match the Two-Loudspeaker Technique?
title_sort dpoae responses in humans and ear models can a single loudspeaker approach match the two loudspeaker technique
topic DPOAE
intermodulation distortion
single-loudspeaker setup
silicone ear models
url https://ieeexplore.ieee.org/document/11036177/
work_keys_str_mv AT irwansyah dpoaeresponsesinhumansandearmodelscanasingleloudspeakerapproachmatchthetwoloudspeakertechnique
AT shootsuka dpoaeresponsesinhumansandearmodelscanasingleloudspeakerapproachmatchthetwoloudspeakertechnique
AT seijinakagawa dpoaeresponsesinhumansandearmodelscanasingleloudspeakerapproachmatchthetwoloudspeakertechnique