USING OF DIFFERENT NOZZLES (SINGLE AND DOUBLE )UNDER TWO PRESSURES TO SHOW THERE EFFECT ON COEFFICIENT OF UNIFORMITY AND DISTRIBUTION UNIFORMITY OF WATER DISTRIBUTION UNDER STATIONARY SPRINGULAR IRRIGATION
This study was conducted in the fields of Agriculture and forestry collage in February 2010 to investigate the effect of pressure 1.5 and 3 bar and type of nozzle single ( square , hexagon , circular ) and double ( square × circular , hexagon × circular , circular × circular ) on the uniformity coe...
Saved in:
| Main Author: | |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
College of Agriculture
2012-06-01
|
| Series: | Mesopotamia Journal of Agriculture |
| Online Access: | https://magrj.mosuljournals.com/article_32816_10289a133550dbd64553b291b4476a53.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850251968928284672 |
|---|---|
| author | Essam A. Taha |
| author_facet | Essam A. Taha |
| author_sort | Essam A. Taha |
| collection | DOAJ |
| description | This study was conducted in the fields of Agriculture and forestry collage in February 2010 to investigate the effect of pressure 1.5 and 3 bar and type of nozzle single ( square , hexagon , circular ) and double ( square × circular , hexagon × circular , circular × circular ) on the uniformity coefficient of water distribution ( UC ) and distribution uniformity ( DU ) . The randomized block design and Duncan's multiple range test for comparison between the means were used . Results showed that there were significant differences among the two factor , the presser 3 bar gave the highest coefficient of water distribution uniformity and distribution uniformity the circular single nozzle gave the highest coefficient and distribution uniformity at pressure 1.5 , 3 bar comparing with the other nozzle , The double nozzle (circular × circular ) gave the highest coefficient and distribution uniformity at pressure 3 bar . |
| format | Article |
| id | doaj-art-73fc95b538dd4db08f29e098d5e776f5 |
| institution | OA Journals |
| issn | 1815-316X 2224-9796 |
| language | English |
| publishDate | 2012-06-01 |
| publisher | College of Agriculture |
| record_format | Article |
| series | Mesopotamia Journal of Agriculture |
| spelling | doaj-art-73fc95b538dd4db08f29e098d5e776f52025-08-20T01:57:47ZengCollege of AgricultureMesopotamia Journal of Agriculture1815-316X2224-97962012-06-0140122522910.33899/magrj.2012.3281632816USING OF DIFFERENT NOZZLES (SINGLE AND DOUBLE )UNDER TWO PRESSURES TO SHOW THERE EFFECT ON COEFFICIENT OF UNIFORMITY AND DISTRIBUTION UNIFORMITY OF WATER DISTRIBUTION UNDER STATIONARY SPRINGULAR IRRIGATIONEssam A. TahaThis study was conducted in the fields of Agriculture and forestry collage in February 2010 to investigate the effect of pressure 1.5 and 3 bar and type of nozzle single ( square , hexagon , circular ) and double ( square × circular , hexagon × circular , circular × circular ) on the uniformity coefficient of water distribution ( UC ) and distribution uniformity ( DU ) . The randomized block design and Duncan's multiple range test for comparison between the means were used . Results showed that there were significant differences among the two factor , the presser 3 bar gave the highest coefficient of water distribution uniformity and distribution uniformity the circular single nozzle gave the highest coefficient and distribution uniformity at pressure 1.5 , 3 bar comparing with the other nozzle , The double nozzle (circular × circular ) gave the highest coefficient and distribution uniformity at pressure 3 bar .https://magrj.mosuljournals.com/article_32816_10289a133550dbd64553b291b4476a53.pdf |
| spellingShingle | Essam A. Taha USING OF DIFFERENT NOZZLES (SINGLE AND DOUBLE )UNDER TWO PRESSURES TO SHOW THERE EFFECT ON COEFFICIENT OF UNIFORMITY AND DISTRIBUTION UNIFORMITY OF WATER DISTRIBUTION UNDER STATIONARY SPRINGULAR IRRIGATION Mesopotamia Journal of Agriculture |
| title | USING OF DIFFERENT NOZZLES (SINGLE AND DOUBLE )UNDER TWO PRESSURES TO SHOW THERE EFFECT ON COEFFICIENT OF UNIFORMITY AND DISTRIBUTION UNIFORMITY OF WATER DISTRIBUTION UNDER STATIONARY SPRINGULAR IRRIGATION |
| title_full | USING OF DIFFERENT NOZZLES (SINGLE AND DOUBLE )UNDER TWO PRESSURES TO SHOW THERE EFFECT ON COEFFICIENT OF UNIFORMITY AND DISTRIBUTION UNIFORMITY OF WATER DISTRIBUTION UNDER STATIONARY SPRINGULAR IRRIGATION |
| title_fullStr | USING OF DIFFERENT NOZZLES (SINGLE AND DOUBLE )UNDER TWO PRESSURES TO SHOW THERE EFFECT ON COEFFICIENT OF UNIFORMITY AND DISTRIBUTION UNIFORMITY OF WATER DISTRIBUTION UNDER STATIONARY SPRINGULAR IRRIGATION |
| title_full_unstemmed | USING OF DIFFERENT NOZZLES (SINGLE AND DOUBLE )UNDER TWO PRESSURES TO SHOW THERE EFFECT ON COEFFICIENT OF UNIFORMITY AND DISTRIBUTION UNIFORMITY OF WATER DISTRIBUTION UNDER STATIONARY SPRINGULAR IRRIGATION |
| title_short | USING OF DIFFERENT NOZZLES (SINGLE AND DOUBLE )UNDER TWO PRESSURES TO SHOW THERE EFFECT ON COEFFICIENT OF UNIFORMITY AND DISTRIBUTION UNIFORMITY OF WATER DISTRIBUTION UNDER STATIONARY SPRINGULAR IRRIGATION |
| title_sort | using of different nozzles single and double under two pressures to show there effect on coefficient of uniformity and distribution uniformity of water distribution under stationary springular irrigation |
| url | https://magrj.mosuljournals.com/article_32816_10289a133550dbd64553b291b4476a53.pdf |
| work_keys_str_mv | AT essamataha usingofdifferentnozzlessingleanddoubleundertwopressurestoshowthereeffectoncoefficientofuniformityanddistributionuniformityofwaterdistributionunderstationaryspringularirrigation |