Errors analysis in pyrometric measurements in industrial environment

The article presents the analysis of uncertainties associated with reliable accounting difficulties for the radiation coefficient in non-contact temperature measurement in industrial environment. Practical recommendations of methodological and instrumental nature to reduce such measurements erro...

Full description

Saved in:
Bibliographic Details
Main Authors: D. B. Ponomarev, V. A. Zakharenko, E. V. Abramova
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2019-11-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/5%20(167)/94-99%20%D0%9F%D0%BE%D0%BD%D0%BE%D0%BC%D0%B0%D1%80%D0%B5%D0%B2%20%D0%94.%20%D0%91.,%20%D0%97%D0%B0%D1%85%D0%B0%D1%80%D0%B5%D0%BD%D0%BA%D0%BE%20%D0%92.%20%D0%90.,%20%D0%90%D0%B1%D1%80%D0%B0%D0%BC%D0%BE%D0%B2%D0%B0%20%D0%95.%20%D0%92..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832572813629718528
author D. B. Ponomarev
V. A. Zakharenko
E. V. Abramova
author_facet D. B. Ponomarev
V. A. Zakharenko
E. V. Abramova
author_sort D. B. Ponomarev
collection DOAJ
description The article presents the analysis of uncertainties associated with reliable accounting difficulties for the radiation coefficient in non-contact temperature measurement in industrial environment. Practical recommendations of methodological and instrumental nature to reduce such measurements errors are offered. On the Planck function and the aluminum reflection coefficient mathematical model basis the analytical aluminum radiation coefficient dependence on temperature and wavelength is obtained. Methodological errors estimates of low-temperature thermometers with a spectral sensitivity ranges equal to 7–14 and 3–5 µm are produced. Experimental studies are carried out using Optris CT LT15 pyrometer and Flir E60 infrared imager.
format Article
id doaj-art-72215c9e8f314c569229a655e06e4d7a
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2019-11-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-72215c9e8f314c569229a655e06e4d7a2025-02-02T07:04:08ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412019-11-015 (167)949910.25206/1813-8225-2019-167-94-99Errors analysis in pyrometric measurements in industrial environmentD. B. Ponomarev0https://orcid.org/0000-0002-5206-0756V. A. Zakharenko1E. V. Abramova2Omsk State Technical UniversityOmsk State Technical UniversityBauman Moscow State Technical UniversityThe article presents the analysis of uncertainties associated with reliable accounting difficulties for the radiation coefficient in non-contact temperature measurement in industrial environment. Practical recommendations of methodological and instrumental nature to reduce such measurements errors are offered. On the Planck function and the aluminum reflection coefficient mathematical model basis the analytical aluminum radiation coefficient dependence on temperature and wavelength is obtained. Methodological errors estimates of low-temperature thermometers with a spectral sensitivity ranges equal to 7–14 and 3–5 µm are produced. Experimental studies are carried out using Optris CT LT15 pyrometer and Flir E60 infrared imager.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/5%20(167)/94-99%20%D0%9F%D0%BE%D0%BD%D0%BE%D0%BC%D0%B0%D1%80%D0%B5%D0%B2%20%D0%94.%20%D0%91.,%20%D0%97%D0%B0%D1%85%D0%B0%D1%80%D0%B5%D0%BD%D0%BA%D0%BE%20%D0%92.%20%D0%90.,%20%D0%90%D0%B1%D1%80%D0%B0%D0%BC%D0%BE%D0%B2%D0%B0%20%D0%95.%20%D0%92..pdfpyrometeremissivitymethodological errorinstrumental errorcalibratorspectral ratio
spellingShingle D. B. Ponomarev
V. A. Zakharenko
E. V. Abramova
Errors analysis in pyrometric measurements in industrial environment
Омский научный вестник
pyrometer
emissivity
methodological error
instrumental error
calibrator
spectral ratio
title Errors analysis in pyrometric measurements in industrial environment
title_full Errors analysis in pyrometric measurements in industrial environment
title_fullStr Errors analysis in pyrometric measurements in industrial environment
title_full_unstemmed Errors analysis in pyrometric measurements in industrial environment
title_short Errors analysis in pyrometric measurements in industrial environment
title_sort errors analysis in pyrometric measurements in industrial environment
topic pyrometer
emissivity
methodological error
instrumental error
calibrator
spectral ratio
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2019/5%20(167)/94-99%20%D0%9F%D0%BE%D0%BD%D0%BE%D0%BC%D0%B0%D1%80%D0%B5%D0%B2%20%D0%94.%20%D0%91.,%20%D0%97%D0%B0%D1%85%D0%B0%D1%80%D0%B5%D0%BD%D0%BA%D0%BE%20%D0%92.%20%D0%90.,%20%D0%90%D0%B1%D1%80%D0%B0%D0%BC%D0%BE%D0%B2%D0%B0%20%D0%95.%20%D0%92..pdf
work_keys_str_mv AT dbponomarev errorsanalysisinpyrometricmeasurementsinindustrialenvironment
AT vazakharenko errorsanalysisinpyrometricmeasurementsinindustrialenvironment
AT evabramova errorsanalysisinpyrometricmeasurementsinindustrialenvironment