Evaluation of the efficacy of combined vitamin D3 and K2 therapy in reducing implant-associated complication risk and improving spinal fusion stability

In the last decade, the use of implants in spinal surgery has significantly increased, particularly interbody devices and transpedicular fixators. This trend has necessitated refining approaches aimed at preventing intra- and postoperative complications. A key factor influencing the effec...

Full description

Saved in:
Bibliographic Details
Main Authors: Oleksii S. Nekhlopochyn, Iryna G. Vasylieva, Nataliia G. Chopyk, Vadim V. Verbov, Ievgen V. Cheshuk, Milan V. Vorodi
Format: Article
Language:English
Published: Romodanov Neurosurgery Institute 2025-06-01
Series:Ukrainian Neurosurgical Journal
Online Access:https://theunj.org/article/view/320680
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849423320089362432
author Oleksii S. Nekhlopochyn
Iryna G. Vasylieva
Nataliia G. Chopyk
Vadim V. Verbov
Ievgen V. Cheshuk
Milan V. Vorodi
author_facet Oleksii S. Nekhlopochyn
Iryna G. Vasylieva
Nataliia G. Chopyk
Vadim V. Verbov
Ievgen V. Cheshuk
Milan V. Vorodi
author_sort Oleksii S. Nekhlopochyn
collection DOAJ
description In the last decade, the use of implants in spinal surgery has significantly increased, particularly interbody devices and transpedicular fixators. This trend has necessitated refining approaches aimed at preventing intra- and postoperative complications. A key factor influencing the effectiveness of stabilization procedures is bone mineral density (BMD). Objective: To investigate the relationship among vitamin D levels, BMD, and the incidence of implant-related failures in patients who have undergone stabilization procedures on the spine, as well as to evaluate the role of postoperative correction of vitamin D₃ and K2 deficiencies in enhancing fixation stability and reducing complication risks. Materials and Methods: A retrospective single-center cohort study was conducted in specialized departments of Romodanov Neurosurgery Institute NAMS of Ukraine, from January 2023 to December 2024. A total of 250 patients who underwent spinal surgery with the use of transpedicular screws and/or interbody implants were analyzed with respect to their age, sex, body mass index, serum vitamin D (25-(OH)D₃) levels, and BMD (according to computed tomography data). Original grading scales were used to evaluate implant-related complications. Postoperative correction of vitamin D deficiency was carried out using “Solemax®” (vitamin D₃, vitamin K2, and ω-3 polyunsaturated fatty acids). Results: A high prevalence of vitamin D deficiency and reduced BMD was recorded among patients undergoing elective stabilization surgeries on the spine. A significant correlation was detected between 25-(OH)D₃ levels and bone tissue status. After 4 months of “Solemax®” administration, all patients achieved reference 25-(OH)D3 levels, indicating the effectiveness of the therapy. In the correction group, an increase in BMD was observed, whereas in the comparison group, BMD values decreased. The incidence of implant-related complications was statistically reduced: the risk of screw loosening decreased by 69.84% over the first 6 months and by 85.06% over one year, while the risk of interbody implant migration declined by 56.2% and 64.7%, respectively. Conclusions: The stability of spinal fusion is more contingent upon the adaptive response of bone tissue to implantation than on absolute BMD values. The use of a balanced combination of vitamins D₃ and K2 contributes to enhanced fixation stability and a lower risk of postoperative complications.
format Article
id doaj-art-7211c24d270a4e7e9eae9e21e7e8ac42
institution Kabale University
issn 2663-9084
2663-9092
language English
publishDate 2025-06-01
publisher Romodanov Neurosurgery Institute
record_format Article
series Ukrainian Neurosurgical Journal
spelling doaj-art-7211c24d270a4e7e9eae9e21e7e8ac422025-08-20T03:30:39ZengRomodanov Neurosurgery InstituteUkrainian Neurosurgical Journal2663-90842663-90922025-06-01312102710.25305/unj.320680Evaluation of the efficacy of combined vitamin D3 and K2 therapy in reducing implant-associated complication risk and improving spinal fusion stabilityOleksii S. Nekhlopochyn0https://orcid.org/0000-0002-1180-6881Iryna G. Vasylieva1https://orcid.org/0000-0003-4321-5354Nataliia G. Chopyk2https://orcid.org/0000-0003-1024-1556Vadim V. Verbov3https://orcid.org/0000-0002-3074-9915Ievgen V. Cheshuk4https://orcid.org/0000-0002-8063-2141Milan V. Vorodi5https://orcid.org/0000-0001-5099-4603Spine Surgery Department, Romodanov Neurosurgery Institute, KyivNeurobiochemistry Department, Romodanov Neurosurgery Institute, KyivNeurobiochemistry Department, Romodanov Neurosurgery Institute, KyivRestorative Neurosurgery Department, Romodanov Neurosurgery Institute, KyivRestorative Neurosurgery Department, Romodanov Neurosurgery Institute, KyivRestorative Neurosurgery Department, Romodanov Neurosurgery Institute, Kyiv In the last decade, the use of implants in spinal surgery has significantly increased, particularly interbody devices and transpedicular fixators. This trend has necessitated refining approaches aimed at preventing intra- and postoperative complications. A key factor influencing the effectiveness of stabilization procedures is bone mineral density (BMD). Objective: To investigate the relationship among vitamin D levels, BMD, and the incidence of implant-related failures in patients who have undergone stabilization procedures on the spine, as well as to evaluate the role of postoperative correction of vitamin D₃ and K2 deficiencies in enhancing fixation stability and reducing complication risks. Materials and Methods: A retrospective single-center cohort study was conducted in specialized departments of Romodanov Neurosurgery Institute NAMS of Ukraine, from January 2023 to December 2024. A total of 250 patients who underwent spinal surgery with the use of transpedicular screws and/or interbody implants were analyzed with respect to their age, sex, body mass index, serum vitamin D (25-(OH)D₃) levels, and BMD (according to computed tomography data). Original grading scales were used to evaluate implant-related complications. Postoperative correction of vitamin D deficiency was carried out using “Solemax®” (vitamin D₃, vitamin K2, and ω-3 polyunsaturated fatty acids). Results: A high prevalence of vitamin D deficiency and reduced BMD was recorded among patients undergoing elective stabilization surgeries on the spine. A significant correlation was detected between 25-(OH)D₃ levels and bone tissue status. After 4 months of “Solemax®” administration, all patients achieved reference 25-(OH)D3 levels, indicating the effectiveness of the therapy. In the correction group, an increase in BMD was observed, whereas in the comparison group, BMD values decreased. The incidence of implant-related complications was statistically reduced: the risk of screw loosening decreased by 69.84% over the first 6 months and by 85.06% over one year, while the risk of interbody implant migration declined by 56.2% and 64.7%, respectively. Conclusions: The stability of spinal fusion is more contingent upon the adaptive response of bone tissue to implantation than on absolute BMD values. The use of a balanced combination of vitamins D₃ and K2 contributes to enhanced fixation stability and a lower risk of postoperative complications.https://theunj.org/article/view/320680
spellingShingle Oleksii S. Nekhlopochyn
Iryna G. Vasylieva
Nataliia G. Chopyk
Vadim V. Verbov
Ievgen V. Cheshuk
Milan V. Vorodi
Evaluation of the efficacy of combined vitamin D3 and K2 therapy in reducing implant-associated complication risk and improving spinal fusion stability
Ukrainian Neurosurgical Journal
title Evaluation of the efficacy of combined vitamin D3 and K2 therapy in reducing implant-associated complication risk and improving spinal fusion stability
title_full Evaluation of the efficacy of combined vitamin D3 and K2 therapy in reducing implant-associated complication risk and improving spinal fusion stability
title_fullStr Evaluation of the efficacy of combined vitamin D3 and K2 therapy in reducing implant-associated complication risk and improving spinal fusion stability
title_full_unstemmed Evaluation of the efficacy of combined vitamin D3 and K2 therapy in reducing implant-associated complication risk and improving spinal fusion stability
title_short Evaluation of the efficacy of combined vitamin D3 and K2 therapy in reducing implant-associated complication risk and improving spinal fusion stability
title_sort evaluation of the efficacy of combined vitamin d3 and k2 therapy in reducing implant associated complication risk and improving spinal fusion stability
url https://theunj.org/article/view/320680
work_keys_str_mv AT oleksiisnekhlopochyn evaluationoftheefficacyofcombinedvitamind3andk2therapyinreducingimplantassociatedcomplicationriskandimprovingspinalfusionstability
AT irynagvasylieva evaluationoftheefficacyofcombinedvitamind3andk2therapyinreducingimplantassociatedcomplicationriskandimprovingspinalfusionstability
AT nataliiagchopyk evaluationoftheefficacyofcombinedvitamind3andk2therapyinreducingimplantassociatedcomplicationriskandimprovingspinalfusionstability
AT vadimvverbov evaluationoftheefficacyofcombinedvitamind3andk2therapyinreducingimplantassociatedcomplicationriskandimprovingspinalfusionstability
AT ievgenvcheshuk evaluationoftheefficacyofcombinedvitamind3andk2therapyinreducingimplantassociatedcomplicationriskandimprovingspinalfusionstability
AT milanvvorodi evaluationoftheefficacyofcombinedvitamind3andk2therapyinreducingimplantassociatedcomplicationriskandimprovingspinalfusionstability