Barcoded labels as potential source of zinc contamination in trace metal testing
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Elsevier
2025-04-01
|
| Series: | Journal of Mass Spectrometry and Advances in the Clinical Lab |
| Subjects: | |
| Online Access: | http://www.sciencedirect.com/science/article/pii/S2667145X25000069 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849324147597901824 |
|---|---|
| author | Difei Sun Donna Sealy Dorothy Truong Danijela Konforte |
| author_facet | Difei Sun Donna Sealy Dorothy Truong Danijela Konforte |
| author_sort | Difei Sun |
| collection | DOAJ |
| format | Article |
| id | doaj-art-71bb9bf4b6aa43beafd8bd58133fd5c7 |
| institution | Kabale University |
| issn | 2667-145X |
| language | English |
| publishDate | 2025-04-01 |
| publisher | Elsevier |
| record_format | Article |
| series | Journal of Mass Spectrometry and Advances in the Clinical Lab |
| spelling | doaj-art-71bb9bf4b6aa43beafd8bd58133fd5c72025-08-20T03:48:47ZengElsevierJournal of Mass Spectrometry and Advances in the Clinical Lab2667-145X2025-04-013691010.1016/j.jmsacl.2025.02.003Barcoded labels as potential source of zinc contamination in trace metal testingDifei Sun0Donna Sealy1Dorothy Truong2Danijela Konforte3Medical-Scientific Department, LifeLabs Medical Laboratory Services, Toronto, ON M9W 6J6, CanadaLaboratory Operations Department, LifeLabs Medical Laboratory Services, Toronto, ON M9W 6J6, CanadaMedical-Scientific Department, LifeLabs Medical Laboratory Services, Toronto, ON M9W 6J6, CanadaMedical-Scientific Department, LifeLabs Medical Laboratory Services, Toronto, ON M9W 6J6, Canada; Corresponding author.http://www.sciencedirect.com/science/article/pii/S2667145X25000069Trace metal testingEnvironmental contaminationBarcoded labelsInductively coupled plasma-tandem mass spectrometry (ICP-MS/MS)Zinc |
| spellingShingle | Difei Sun Donna Sealy Dorothy Truong Danijela Konforte Barcoded labels as potential source of zinc contamination in trace metal testing Journal of Mass Spectrometry and Advances in the Clinical Lab Trace metal testing Environmental contamination Barcoded labels Inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) Zinc |
| title | Barcoded labels as potential source of zinc contamination in trace metal testing |
| title_full | Barcoded labels as potential source of zinc contamination in trace metal testing |
| title_fullStr | Barcoded labels as potential source of zinc contamination in trace metal testing |
| title_full_unstemmed | Barcoded labels as potential source of zinc contamination in trace metal testing |
| title_short | Barcoded labels as potential source of zinc contamination in trace metal testing |
| title_sort | barcoded labels as potential source of zinc contamination in trace metal testing |
| topic | Trace metal testing Environmental contamination Barcoded labels Inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) Zinc |
| url | http://www.sciencedirect.com/science/article/pii/S2667145X25000069 |
| work_keys_str_mv | AT difeisun barcodedlabelsaspotentialsourceofzinccontaminationintracemetaltesting AT donnasealy barcodedlabelsaspotentialsourceofzinccontaminationintracemetaltesting AT dorothytruong barcodedlabelsaspotentialsourceofzinccontaminationintracemetaltesting AT danijelakonforte barcodedlabelsaspotentialsourceofzinccontaminationintracemetaltesting |