Ground water quality in Ciracas sub-district, East Jakarta, Indonesia

The study aimed to know, and get a picture of the condition of groundwater quality in the area of Ciracas Urban Sub-District, Ciracas District, East Jakarta, Indonesia. Besides, to know the groundwater in the residential area of Ciracas Sub-district, East Jakarta has been contaminated or not based o...

Full description

Saved in:
Bibliographic Details
Main Authors: A. Alwin, Tri Cahyono, Ali Sya’ban, Siti Dahlia
Format: Article
Language:English
Published: University of Guilan 2023-04-01
Series:Caspian Journal of Environmental Sciences
Subjects:
Online Access:https://cjes.guilan.ac.ir/article_6501_1e5d702a2344ed7edcf2d5901931e3b0.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850254558953996288
author A. Alwin
Tri Cahyono
Ali Sya’ban
Siti Dahlia
author_facet A. Alwin
Tri Cahyono
Ali Sya’ban
Siti Dahlia
author_sort A. Alwin
collection DOAJ
description The study aimed to know, and get a picture of the condition of groundwater quality in the area of Ciracas Urban Sub-District, Ciracas District, East Jakarta, Indonesia. Besides, to know the groundwater in the residential area of Ciracas Sub-district, East Jakarta has been contaminated or not based on Permenkes RI's clean water quality standard. No.416 / Menkes / per / IX / 1990. This is a descriptive study based on laboratory analyses. To determine groundwater samples in the study area, we used a sampling technique based on settlement density. The results of the study exhibited that the condition of ground water quality in the study area, according to the physical quality parameters, was odorless. Total dissolved solids (TDS) ranged from 489.1 mg L-1 to 298.2 mg L-1; turbidity ranged from 0.30 to 45.08 NTU. Unwelcome, temperature was 30 °C, color ranged between 4 and 13 TCU. Chemical quality of iron (Fe) ranged from 1600 MPN / 100 mL, while total bacterial coliform content was allowed at 50 MPN / 100 mL. This means that groundwater in Ciracas Urban Sub-District, Ciracas District, East Jakarta can not be used as a source of clean water.
format Article
id doaj-art-717fcbe7fded496bab0230cc17ad4f99
institution OA Journals
issn 1735-3033
1735-3866
language English
publishDate 2023-04-01
publisher University of Guilan
record_format Article
series Caspian Journal of Environmental Sciences
spelling doaj-art-717fcbe7fded496bab0230cc17ad4f992025-08-20T01:57:05ZengUniversity of GuilanCaspian Journal of Environmental Sciences1735-30331735-38662023-04-0121234935410.22124/cjes.2023.65016501Ground water quality in Ciracas sub-district, East Jakarta, IndonesiaA. Alwin0Tri Cahyono1Ali Sya’ban2Siti Dahlia3Geography Education Study Program, Prof. Dr. Hamka Muhammadiyah University, Jakarta, IndonesiaGeography Education Study Program, Prof. Dr. Hamka Muhammadiyah University, Jakarta, IndonesiaGeography Education Study Program, Prof. Dr. Hamka Muhammadiyah University, Jakarta, IndonesiaGeography Education Study Program, Prof. Dr. Hamka Muhammadiyah University, Jakarta, IndonesiaThe study aimed to know, and get a picture of the condition of groundwater quality in the area of Ciracas Urban Sub-District, Ciracas District, East Jakarta, Indonesia. Besides, to know the groundwater in the residential area of Ciracas Sub-district, East Jakarta has been contaminated or not based on Permenkes RI's clean water quality standard. No.416 / Menkes / per / IX / 1990. This is a descriptive study based on laboratory analyses. To determine groundwater samples in the study area, we used a sampling technique based on settlement density. The results of the study exhibited that the condition of ground water quality in the study area, according to the physical quality parameters, was odorless. Total dissolved solids (TDS) ranged from 489.1 mg L-1 to 298.2 mg L-1; turbidity ranged from 0.30 to 45.08 NTU. Unwelcome, temperature was 30 °C, color ranged between 4 and 13 TCU. Chemical quality of iron (Fe) ranged from 1600 MPN / 100 mL, while total bacterial coliform content was allowed at 50 MPN / 100 mL. This means that groundwater in Ciracas Urban Sub-District, Ciracas District, East Jakarta can not be used as a source of clean water.https://cjes.guilan.ac.ir/article_6501_1e5d702a2344ed7edcf2d5901931e3b0.pdfwater qualitygroundwaterciracas sub-district
spellingShingle A. Alwin
Tri Cahyono
Ali Sya’ban
Siti Dahlia
Ground water quality in Ciracas sub-district, East Jakarta, Indonesia
Caspian Journal of Environmental Sciences
water quality
groundwater
ciracas sub-district
title Ground water quality in Ciracas sub-district, East Jakarta, Indonesia
title_full Ground water quality in Ciracas sub-district, East Jakarta, Indonesia
title_fullStr Ground water quality in Ciracas sub-district, East Jakarta, Indonesia
title_full_unstemmed Ground water quality in Ciracas sub-district, East Jakarta, Indonesia
title_short Ground water quality in Ciracas sub-district, East Jakarta, Indonesia
title_sort ground water quality in ciracas sub district east jakarta indonesia
topic water quality
groundwater
ciracas sub-district
url https://cjes.guilan.ac.ir/article_6501_1e5d702a2344ed7edcf2d5901931e3b0.pdf
work_keys_str_mv AT aalwin groundwaterqualityinciracassubdistricteastjakartaindonesia
AT tricahyono groundwaterqualityinciracassubdistricteastjakartaindonesia
AT alisyaban groundwaterqualityinciracassubdistricteastjakartaindonesia
AT sitidahlia groundwaterqualityinciracassubdistricteastjakartaindonesia