Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an i...

Full description

Saved in:
Bibliographic Details
Main Authors: Kenneth Armijo, Aaron Overacker, Ansel Blumenthal, Jeffrey Parish, Michael Nelson, Ivica Radman, Javier Martell
Format: Article
Language:English
Published: TIB Open Publishing 2025-02-01
Series:SolarPACES Conference Proceedings
Subjects:
Online Access:https://www.tib-op.org/ojs/index.php/solarpaces/article/view/829
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832541076926234624
author Kenneth Armijo
Aaron Overacker
Ansel Blumenthal
Jeffrey Parish
Michael Nelson
Ivica Radman
Javier Martell
author_facet Kenneth Armijo
Aaron Overacker
Ansel Blumenthal
Jeffrey Parish
Michael Nelson
Ivica Radman
Javier Martell
author_sort Kenneth Armijo
collection DOAJ
description To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.
format Article
id doaj-art-7126d1b6099846da8031b4c73d8a5dc2
institution Kabale University
issn 2751-9899
language English
publishDate 2025-02-01
publisher TIB Open Publishing
record_format Article
series SolarPACES Conference Proceedings
spelling doaj-art-7126d1b6099846da8031b4c73d8a5dc22025-02-04T09:54:13ZengTIB Open PublishingSolarPACES Conference Proceedings2751-98992025-02-01210.52825/solarpaces.v2i.829Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows ValveKenneth Armijo0https://orcid.org/0000-0003-4683-2147Aaron Overacker1Ansel Blumenthal2Jeffrey Parish3Michael Nelson4Ivica Radman5Javier Martell6Sandia National LaboratoriesSandia Research (United States) Sandia Research (United States) Flowserve (Germany) Flowserve (Germany) Flowserve (Germany) Sandia Research (United States) To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV. https://www.tib-op.org/ojs/index.php/solarpaces/article/view/829Molten SaltExperimental ValvesHeat Pipes
spellingShingle Kenneth Armijo
Aaron Overacker
Ansel Blumenthal
Jeffrey Parish
Michael Nelson
Ivica Radman
Javier Martell
Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve
SolarPACES Conference Proceedings
Molten Salt
Experimental Valves
Heat Pipes
title Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve
title_full Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve
title_fullStr Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve
title_full_unstemmed Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve
title_short Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve
title_sort experimental operation of a prototype 750c advanced chloride molten salt bellows valve
topic Molten Salt
Experimental Valves
Heat Pipes
url https://www.tib-op.org/ojs/index.php/solarpaces/article/view/829
work_keys_str_mv AT kennetharmijo experimentaloperationofaprototype750cadvancedchloridemoltensaltbellowsvalve
AT aaronoveracker experimentaloperationofaprototype750cadvancedchloridemoltensaltbellowsvalve
AT anselblumenthal experimentaloperationofaprototype750cadvancedchloridemoltensaltbellowsvalve
AT jeffreyparish experimentaloperationofaprototype750cadvancedchloridemoltensaltbellowsvalve
AT michaelnelson experimentaloperationofaprototype750cadvancedchloridemoltensaltbellowsvalve
AT ivicaradman experimentaloperationofaprototype750cadvancedchloridemoltensaltbellowsvalve
AT javiermartell experimentaloperationofaprototype750cadvancedchloridemoltensaltbellowsvalve