Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution Normality

The variation of the bulk etch rate (VB) of nuclear track detector CR-39 with the normality of the chemical etchant were studied. The removal thickness measurement method is used to determine the bulk etch rate. the detectors were etched by an aqueous solution of  NaOH with normalities (4, 5, 6, 7)...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmed A. Al-obedy, Ammar A. AL-Battawy, Omar K. Younus
Format: Article
Language:English
Published: Tikrit University 2023-02-01
Series:Tikrit Journal of Pure Science
Subjects:
Online Access:https://tjpsj.org/index.php/tjps/article/view/1250
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849427553342717952
author Ahmed A. Al-obedy
Ammar A. AL-Battawy
Omar K. Younus
author_facet Ahmed A. Al-obedy
Ammar A. AL-Battawy
Omar K. Younus
author_sort Ahmed A. Al-obedy
collection DOAJ
description The variation of the bulk etch rate (VB) of nuclear track detector CR-39 with the normality of the chemical etchant were studied. The removal thickness measurement method is used to determine the bulk etch rate. the detectors were etched by an aqueous solution of  NaOH with normalities (4, 5, 6, 7) N at temperature (70±1) oC. It was found that the bulk etch rate is exponentially increasing with the normality of the solution and its values are (0.687, 1.421, 0.954, 2.082) µm/h at normalities (4, 5, 6, 7) N respectively. the relation between the bulk etch rate and the etchant normality was an exponential relation and the results showed good agreement with the results of the others used other normalities and another measurement method.    
format Article
id doaj-art-7006a9dc851f4ff9902f2e2e793160eb
institution Kabale University
issn 1813-1662
2415-1726
language English
publishDate 2023-02-01
publisher Tikrit University
record_format Article
series Tikrit Journal of Pure Science
spelling doaj-art-7006a9dc851f4ff9902f2e2e793160eb2025-08-20T03:28:59ZengTikrit UniversityTikrit Journal of Pure Science1813-16622415-17262023-02-0120510.25130/tjps.v20i5.1250Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution NormalityAhmed A. Al-obedyAmmar A. AL-BattawyOmar K. Younus The variation of the bulk etch rate (VB) of nuclear track detector CR-39 with the normality of the chemical etchant were studied. The removal thickness measurement method is used to determine the bulk etch rate. the detectors were etched by an aqueous solution of  NaOH with normalities (4, 5, 6, 7) N at temperature (70±1) oC. It was found that the bulk etch rate is exponentially increasing with the normality of the solution and its values are (0.687, 1.421, 0.954, 2.082) µm/h at normalities (4, 5, 6, 7) N respectively. the relation between the bulk etch rate and the etchant normality was an exponential relation and the results showed good agreement with the results of the others used other normalities and another measurement method.     https://tjpsj.org/index.php/tjps/article/view/1250VariationBulk Etch RateNuclear Track DetectorCR-39Chemical Etchant Solution
spellingShingle Ahmed A. Al-obedy
Ammar A. AL-Battawy
Omar K. Younus
Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution Normality
Tikrit Journal of Pure Science
Variation
Bulk Etch Rate
Nuclear Track Detector
CR-39
Chemical Etchant Solution
title Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution Normality
title_full Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution Normality
title_fullStr Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution Normality
title_full_unstemmed Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution Normality
title_short Variation of the Bulk Etch Rate of Nuclear Track Detector CR-39 With the Chemical Etchant Solution Normality
title_sort variation of the bulk etch rate of nuclear track detector cr 39 with the chemical etchant solution normality
topic Variation
Bulk Etch Rate
Nuclear Track Detector
CR-39
Chemical Etchant Solution
url https://tjpsj.org/index.php/tjps/article/view/1250
work_keys_str_mv AT ahmedaalobedy variationofthebulketchrateofnucleartrackdetectorcr39withthechemicaletchantsolutionnormality
AT ammaraalbattawy variationofthebulketchrateofnucleartrackdetectorcr39withthechemicaletchantsolutionnormality
AT omarkyounus variationofthebulketchrateofnucleartrackdetectorcr39withthechemicaletchantsolutionnormality