CHROMATOGRAPHIC SYSTEM SUITABILITY TESTING: INFLUENCE OF CORRECTION FACTORS AND LATE ELUTING PEAKS OF IMPURITIES ON THE REQUIREMENT FOR THE SIGNAL-TO-NOISE RATIO (REVIEW)

Introduction. In case of methods of impurities determination quite often there are problems connected both with establishment and with check of implementation of the requirement to necessary sensitivity of a chromatographic system.Text. Influence of correction factors and late eluting peaks of impur...

Full description

Saved in:
Bibliographic Details
Main Author: N. A. Epshtein
Format: Article
Language:Russian
Published: LLC Center of Pharmaceutical Analytics (LLC «CPHA») 2019-02-01
Series:Разработка и регистрация лекарственных средств
Subjects:
Online Access:https://www.pharmjournal.ru/jour/article/view/656
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850047057156374528
author N. A. Epshtein
author_facet N. A. Epshtein
author_sort N. A. Epshtein
collection DOAJ
description Introduction. In case of methods of impurities determination quite often there are problems connected both with establishment and with check of implementation of the requirement to necessary sensitivity of a chromatographic system.Text. Influence of correction factors and late eluting peaks of impurities on the requirement for the signal-to-noise ratio (S/N) for chromatographic system suitability testing is considered.Conclusion. The recommendations are provided how to detect situations at which the requirement of S/N≥10 is insufficient for reliable detecting peaks of all impurities (related substances) and therewith how to correct concentration of test solution and/or the requirement to S/N for system suitability testing.
format Article
id doaj-art-6e9adf92ca3a4746bc7b42d6d4e03b09
institution DOAJ
issn 2305-2066
2658-5049
language Russian
publishDate 2019-02-01
publisher LLC Center of Pharmaceutical Analytics (LLC «CPHA»)
record_format Article
series Разработка и регистрация лекарственных средств
spelling doaj-art-6e9adf92ca3a4746bc7b42d6d4e03b092025-08-20T02:54:18ZrusLLC Center of Pharmaceutical Analytics (LLC «CPHA»)Разработка и регистрация лекарственных средств2305-20662658-50492019-02-018110811210.33380/2305-2066-2019-8-1-108-112656CHROMATOGRAPHIC SYSTEM SUITABILITY TESTING: INFLUENCE OF CORRECTION FACTORS AND LATE ELUTING PEAKS OF IMPURITIES ON THE REQUIREMENT FOR THE SIGNAL-TO-NOISE RATIO (REVIEW)N. A. Epshtein0Center of registration and development of medicines LLC «IRVIN 2»Introduction. In case of methods of impurities determination quite often there are problems connected both with establishment and with check of implementation of the requirement to necessary sensitivity of a chromatographic system.Text. Influence of correction factors and late eluting peaks of impurities on the requirement for the signal-to-noise ratio (S/N) for chromatographic system suitability testing is considered.Conclusion. The recommendations are provided how to detect situations at which the requirement of S/N≥10 is insufficient for reliable detecting peaks of all impurities (related substances) and therewith how to correct concentration of test solution and/or the requirement to S/N for system suitability testing.https://www.pharmjournal.ru/jour/article/view/656signal-to-noise ratiosystem suitabilitycorrection factorslate eluting peaksimpuritiesrelated substances
spellingShingle N. A. Epshtein
CHROMATOGRAPHIC SYSTEM SUITABILITY TESTING: INFLUENCE OF CORRECTION FACTORS AND LATE ELUTING PEAKS OF IMPURITIES ON THE REQUIREMENT FOR THE SIGNAL-TO-NOISE RATIO (REVIEW)
Разработка и регистрация лекарственных средств
signal-to-noise ratio
system suitability
correction factors
late eluting peaks
impurities
related substances
title CHROMATOGRAPHIC SYSTEM SUITABILITY TESTING: INFLUENCE OF CORRECTION FACTORS AND LATE ELUTING PEAKS OF IMPURITIES ON THE REQUIREMENT FOR THE SIGNAL-TO-NOISE RATIO (REVIEW)
title_full CHROMATOGRAPHIC SYSTEM SUITABILITY TESTING: INFLUENCE OF CORRECTION FACTORS AND LATE ELUTING PEAKS OF IMPURITIES ON THE REQUIREMENT FOR THE SIGNAL-TO-NOISE RATIO (REVIEW)
title_fullStr CHROMATOGRAPHIC SYSTEM SUITABILITY TESTING: INFLUENCE OF CORRECTION FACTORS AND LATE ELUTING PEAKS OF IMPURITIES ON THE REQUIREMENT FOR THE SIGNAL-TO-NOISE RATIO (REVIEW)
title_full_unstemmed CHROMATOGRAPHIC SYSTEM SUITABILITY TESTING: INFLUENCE OF CORRECTION FACTORS AND LATE ELUTING PEAKS OF IMPURITIES ON THE REQUIREMENT FOR THE SIGNAL-TO-NOISE RATIO (REVIEW)
title_short CHROMATOGRAPHIC SYSTEM SUITABILITY TESTING: INFLUENCE OF CORRECTION FACTORS AND LATE ELUTING PEAKS OF IMPURITIES ON THE REQUIREMENT FOR THE SIGNAL-TO-NOISE RATIO (REVIEW)
title_sort chromatographic system suitability testing influence of correction factors and late eluting peaks of impurities on the requirement for the signal to noise ratio review
topic signal-to-noise ratio
system suitability
correction factors
late eluting peaks
impurities
related substances
url https://www.pharmjournal.ru/jour/article/view/656
work_keys_str_mv AT naepshtein chromatographicsystemsuitabilitytestinginfluenceofcorrectionfactorsandlateelutingpeaksofimpuritiesontherequirementforthesignaltonoiseratioreview