Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis

Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic ra...

Full description

Saved in:
Bibliographic Details
Main Authors: Rahul Vaidya, Ndidi Onwudiwe, Matthew Roth, Anil Sethi
Format: Article
Language:English
Published: Wiley 2013-01-01
Series:Advances in Orthopedics
Online Access:http://dx.doi.org/10.1155/2013/683120
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832563781162500096
author Rahul Vaidya
Ndidi Onwudiwe
Matthew Roth
Anil Sethi
author_facet Rahul Vaidya
Ndidi Onwudiwe
Matthew Roth
Anil Sethi
author_sort Rahul Vaidya
collection DOAJ
description Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw systems showed higher stiffness (4.008 ± 0.113 Nmm monoaxial, 3.638 ± 0.108 Nmm Click-x; 3.634 ± 0.147 Nmm Pangea) than the exfix system (2.882 ± 0.054 Nmm) in distraction. In failure testing, monoaxial pedicle screw system was stronger (360 N) than exfixes (160 N) and polyaxial devices which failed if distracted greater than 4 cm (157 N Click-x or 138 N Pangea). The exfix had higher peak torque and torsional stiffness than all pedicle systems. In torsion, the yield strengths were the same for all constructs. Conclusion. The infix device constructed with polyaxial or monoaxial pedicle screws is stiffer than the 2 pin external fixator in distraction testing. In extreme cases, the use of reinforcement or monoaxial systems which do not fail even at 360 N is a better option. In torsional testing, the 2 pin external fixator is stiffer than the pedicle screw systems.
format Article
id doaj-art-6df175390808465188f09ff8bd613167
institution Kabale University
issn 2090-3464
2090-3472
language English
publishDate 2013-01-01
publisher Wiley
record_format Article
series Advances in Orthopedics
spelling doaj-art-6df175390808465188f09ff8bd6131672025-02-03T01:12:31ZengWileyAdvances in Orthopedics2090-34642090-34722013-01-01201310.1155/2013/683120683120Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical AnalysisRahul Vaidya0Ndidi Onwudiwe1Matthew Roth2Anil Sethi3Detroit Medical Center, Orthopedics Department, Wayne State School of Medicine, 4D UHC, St. Antoine Street, 540 E Canfield Street, Detroit, MI 48201, USADetroit Medical Center, Orthopedics Department, Wayne State School of Medicine, 4D UHC, St. Antoine Street, 540 E Canfield Street, Detroit, MI 48201, USADetroit Medical Center, Orthopedics Department, Wayne State School of Medicine, 4D UHC, St. Antoine Street, 540 E Canfield Street, Detroit, MI 48201, USADetroit Medical Center, Orthopedics Department, Wayne State School of Medicine, 4D UHC, St. Antoine Street, 540 E Canfield Street, Detroit, MI 48201, USAPurpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw systems showed higher stiffness (4.008 ± 0.113 Nmm monoaxial, 3.638 ± 0.108 Nmm Click-x; 3.634 ± 0.147 Nmm Pangea) than the exfix system (2.882 ± 0.054 Nmm) in distraction. In failure testing, monoaxial pedicle screw system was stronger (360 N) than exfixes (160 N) and polyaxial devices which failed if distracted greater than 4 cm (157 N Click-x or 138 N Pangea). The exfix had higher peak torque and torsional stiffness than all pedicle systems. In torsion, the yield strengths were the same for all constructs. Conclusion. The infix device constructed with polyaxial or monoaxial pedicle screws is stiffer than the 2 pin external fixator in distraction testing. In extreme cases, the use of reinforcement or monoaxial systems which do not fail even at 360 N is a better option. In torsional testing, the 2 pin external fixator is stiffer than the pedicle screw systems.http://dx.doi.org/10.1155/2013/683120
spellingShingle Rahul Vaidya
Ndidi Onwudiwe
Matthew Roth
Anil Sethi
Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis
Advances in Orthopedics
title Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis
title_full Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis
title_fullStr Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis
title_full_unstemmed Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis
title_short Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis
title_sort monoaxial pedicle screws are superior to polyaxial pedicle screws and the two pin external fixator for subcutaneous anterior pelvic fixation in a biomechanical analysis
url http://dx.doi.org/10.1155/2013/683120
work_keys_str_mv AT rahulvaidya monoaxialpediclescrewsaresuperiortopolyaxialpediclescrewsandthetwopinexternalfixatorforsubcutaneousanteriorpelvicfixationinabiomechanicalanalysis
AT ndidionwudiwe monoaxialpediclescrewsaresuperiortopolyaxialpediclescrewsandthetwopinexternalfixatorforsubcutaneousanteriorpelvicfixationinabiomechanicalanalysis
AT matthewroth monoaxialpediclescrewsaresuperiortopolyaxialpediclescrewsandthetwopinexternalfixatorforsubcutaneousanteriorpelvicfixationinabiomechanicalanalysis
AT anilsethi monoaxialpediclescrewsaresuperiortopolyaxialpediclescrewsandthetwopinexternalfixatorforsubcutaneousanteriorpelvicfixationinabiomechanicalanalysis