Comparative study of laboratory and portable spot permeability measurements in bioturbated carbonate strata
Abstract In bioturbated strata, defining and obtaining a representative elementary volume for permeability measurements presents significant challenges. To address this, spot permeability is often used as an alternative method to estimate the bulk permeability of these complex strata. However, labor...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Nature Portfolio
2025-05-01
|
| Series: | Scientific Reports |
| Subjects: | |
| Online Access: | https://doi.org/10.1038/s41598-025-00697-w |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850190735907749888 |
|---|---|
| author | Ayman Al-Lehyani Hassan A. Eltom Abdullatif Al-Shuhail Eassa Abdullah Ammar El-Husseiny |
| author_facet | Ayman Al-Lehyani Hassan A. Eltom Abdullatif Al-Shuhail Eassa Abdullah Ammar El-Husseiny |
| author_sort | Ayman Al-Lehyani |
| collection | DOAJ |
| description | Abstract In bioturbated strata, defining and obtaining a representative elementary volume for permeability measurements presents significant challenges. To address this, spot permeability is often used as an alternative method to estimate the bulk permeability of these complex strata. However, laboratory measurements of spot permeability require steady-state nitrogen gas injection and careful sample preparation including slab cutting which makes the process both time-consuming and resource-intensive. Alternatively, field measurements using portable devices offer a more cost-effective, straightforward, and real-time approach for assessing permeability in situ. To evaluate the accuracy of portable devices in measuring spot permeability in bioturbated strata, we compare and contrast permeability measurements on the same rock samples (from the Hanifa Formation in central Saudi Arabia) using two different techniques: the sophisticated laboratory-based AutoScan system and the portable TinyPerm 3 field device both from New England Research (NER). Two sets of permeability data comprising 64 measurements were obtained and analyzed graphically using Whisker Box Plots, Bland-Altman Plot, Curve Matching, and Cross Plots, as well as statistically through correlation analysis and analysis of variance (ANOVA). The graphical analysis revealed no substantial difference in permeability measured by the two methods, a finding further supported by ANOVA results, which indicated no statistically significant difference (P-value > 0.05). Additionally, the correlation plot between the permeability measurements from the two methods yielded a straight line with an R $$^2$$ value greater than 0.9, demonstrating a strong agreement. This study highlights the potential of using portable handheld permeameters to measure spot permeability of bioturbated strata in the field, offering a cost-effective, accurate, and real-time alternative to laboratory-based techniques in estimating their bulk permeability. |
| format | Article |
| id | doaj-art-6dbf70f8586e4d1eb045dabf20602076 |
| institution | OA Journals |
| issn | 2045-2322 |
| language | English |
| publishDate | 2025-05-01 |
| publisher | Nature Portfolio |
| record_format | Article |
| series | Scientific Reports |
| spelling | doaj-art-6dbf70f8586e4d1eb045dabf206020762025-08-20T02:15:11ZengNature PortfolioScientific Reports2045-23222025-05-0115111310.1038/s41598-025-00697-wComparative study of laboratory and portable spot permeability measurements in bioturbated carbonate strataAyman Al-Lehyani0Hassan A. Eltom1Abdullatif Al-Shuhail2Eassa Abdullah3Ammar El-Husseiny4Geosciences Department, College of Petroleum Engineering Geosciences, King Fahd University of Petroleum & MineralsGeosciences Department, College of Petroleum Engineering Geosciences, King Fahd University of Petroleum & MineralsGeosciences Department, College of Petroleum Engineering Geosciences, King Fahd University of Petroleum & MineralsCenter for Integrative Petroleum Research, College of Petroleum Engineering Geosciences, King Fahd University of Petroleum & MineralsGeosciences Department, College of Petroleum Engineering Geosciences, King Fahd University of Petroleum & MineralsAbstract In bioturbated strata, defining and obtaining a representative elementary volume for permeability measurements presents significant challenges. To address this, spot permeability is often used as an alternative method to estimate the bulk permeability of these complex strata. However, laboratory measurements of spot permeability require steady-state nitrogen gas injection and careful sample preparation including slab cutting which makes the process both time-consuming and resource-intensive. Alternatively, field measurements using portable devices offer a more cost-effective, straightforward, and real-time approach for assessing permeability in situ. To evaluate the accuracy of portable devices in measuring spot permeability in bioturbated strata, we compare and contrast permeability measurements on the same rock samples (from the Hanifa Formation in central Saudi Arabia) using two different techniques: the sophisticated laboratory-based AutoScan system and the portable TinyPerm 3 field device both from New England Research (NER). Two sets of permeability data comprising 64 measurements were obtained and analyzed graphically using Whisker Box Plots, Bland-Altman Plot, Curve Matching, and Cross Plots, as well as statistically through correlation analysis and analysis of variance (ANOVA). The graphical analysis revealed no substantial difference in permeability measured by the two methods, a finding further supported by ANOVA results, which indicated no statistically significant difference (P-value > 0.05). Additionally, the correlation plot between the permeability measurements from the two methods yielded a straight line with an R $$^2$$ value greater than 0.9, demonstrating a strong agreement. This study highlights the potential of using portable handheld permeameters to measure spot permeability of bioturbated strata in the field, offering a cost-effective, accurate, and real-time alternative to laboratory-based techniques in estimating their bulk permeability.https://doi.org/10.1038/s41598-025-00697-wSpot permeabilityTinyPerm 3AutoScanBland-Altman plotCarbonateOutcrop |
| spellingShingle | Ayman Al-Lehyani Hassan A. Eltom Abdullatif Al-Shuhail Eassa Abdullah Ammar El-Husseiny Comparative study of laboratory and portable spot permeability measurements in bioturbated carbonate strata Scientific Reports Spot permeability TinyPerm 3 AutoScan Bland-Altman plot Carbonate Outcrop |
| title | Comparative study of laboratory and portable spot permeability measurements in bioturbated carbonate strata |
| title_full | Comparative study of laboratory and portable spot permeability measurements in bioturbated carbonate strata |
| title_fullStr | Comparative study of laboratory and portable spot permeability measurements in bioturbated carbonate strata |
| title_full_unstemmed | Comparative study of laboratory and portable spot permeability measurements in bioturbated carbonate strata |
| title_short | Comparative study of laboratory and portable spot permeability measurements in bioturbated carbonate strata |
| title_sort | comparative study of laboratory and portable spot permeability measurements in bioturbated carbonate strata |
| topic | Spot permeability TinyPerm 3 AutoScan Bland-Altman plot Carbonate Outcrop |
| url | https://doi.org/10.1038/s41598-025-00697-w |
| work_keys_str_mv | AT aymanallehyani comparativestudyoflaboratoryandportablespotpermeabilitymeasurementsinbioturbatedcarbonatestrata AT hassanaeltom comparativestudyoflaboratoryandportablespotpermeabilitymeasurementsinbioturbatedcarbonatestrata AT abdullatifalshuhail comparativestudyoflaboratoryandportablespotpermeabilitymeasurementsinbioturbatedcarbonatestrata AT eassaabdullah comparativestudyoflaboratoryandportablespotpermeabilitymeasurementsinbioturbatedcarbonatestrata AT ammarelhusseiny comparativestudyoflaboratoryandportablespotpermeabilitymeasurementsinbioturbatedcarbonatestrata |