USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE

Aim. The aim of this study focuses on the first experience with self-expandable stents, analysis of its efficacy and safety in the treatment of anastomotic strictures after liver transplantation. Materials and methods. There’re 136 liver transplantations performed from 2004 till 2012. To correct ana...

Full description

Saved in:
Bibliographic Details
Main Authors: M. N. Kornilov, V. V. Gvozdik, A. N. Lotov, Y. G. Moysyuk
Format: Article
Language:Russian
Published: Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov 2013-05-01
Series:Вестник трансплантологии и искусственных органов
Subjects:
Online Access:https://journal.transpl.ru/vtio/article/view/99
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849242052667113472
author M. N. Kornilov
V. V. Gvozdik
A. N. Lotov
Y. G. Moysyuk
author_facet M. N. Kornilov
V. V. Gvozdik
A. N. Lotov
Y. G. Moysyuk
author_sort M. N. Kornilov
collection DOAJ
description Aim. The aim of this study focuses on the first experience with self-expandable stents, analysis of its efficacy and safety in the treatment of anastomotic strictures after liver transplantation. Materials and methods. There’re 136 liver transplantations performed from 2004 till 2012. To correct anastomotic strictures we’ve used only the self-expandable coated nitinol stent. We performed stenting in 7 recipient. Result. In 131 liver transplant recipients incidence of biliary strictures has been 5.3%. All of 5 patients have been managed by retrograde or antegrade way. Conclusion. Our first experience demonstrate efficacy and safety of the used tecniques up to 24 months. The analysis of more long-term results is required.
format Article
id doaj-art-6da91f0dff734227a218998d9af19063
institution Kabale University
issn 1995-1191
language Russian
publishDate 2013-05-01
publisher Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
record_format Article
series Вестник трансплантологии и искусственных органов
spelling doaj-art-6da91f0dff734227a218998d9af190632025-08-20T03:59:56ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.ShumakovВестник трансплантологии и искусственных органов1995-11912013-05-01152505510.15825/1995-1191-2013-2-50-5542USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCEM. N. Kornilov0V. V. Gvozdik1A. N. Lotov2Y. G. Moysyuk3Liver and Kidney transplantation division (Head – prof. Y.G. Moysyuk) Academician V.I. Schumakov Federal Research Center of Transplantology and Artificial Organs, Ministry of Health of the Russian Federation (Head – academician of RAMSci , prof. S.V. Gautier) Moscow, Russian FederationEndoscopy division (Head – cand. of med. sci. V.V. Gvozdik) Medical Center of Major Administration and Moscow Government (Head – O.V. Osadchaya) Moscow, Russian FederationAcute surgical diseases of liver and pancreas division (Head – cand. of med. sci., K.N. Lucyk) Sklifosovsky Research Institute for Emergency Medicine (Head – corresponding member of RAMSci., prof. M.Sh. Khubutiya), Moscow, Russian FederationLiver and Kidney transplantation division (Head – prof. Y.G. Moysyuk) Academician V.I. Schumakov Federal Research Center of Transplantology and Artificial Organs, Ministry of Health of the Russian Federation (Head – academician of RAMSci , prof. S.V. Gautier) Moscow, Russian Federation Chair of transplantology and artificial organs (Head – academician of RAMSci, prof. S.V. Gautier) I.M. Sechenov First Moscow State Medical University (Rector – corresponding member of RAMSci, prof. P.V. Glybochko), Moscow, Russian FederationAim. The aim of this study focuses on the first experience with self-expandable stents, analysis of its efficacy and safety in the treatment of anastomotic strictures after liver transplantation. Materials and methods. There’re 136 liver transplantations performed from 2004 till 2012. To correct anastomotic strictures we’ve used only the self-expandable coated nitinol stent. We performed stenting in 7 recipient. Result. In 131 liver transplant recipients incidence of biliary strictures has been 5.3%. All of 5 patients have been managed by retrograde or antegrade way. Conclusion. Our first experience demonstrate efficacy and safety of the used tecniques up to 24 months. The analysis of more long-term results is required.https://journal.transpl.ru/vtio/article/view/99complications of liver transplantationbiliary stricturestenting of biliary truct
spellingShingle M. N. Kornilov
V. V. Gvozdik
A. N. Lotov
Y. G. Moysyuk
USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE
Вестник трансплантологии и искусственных органов
complications of liver transplantation
biliary stricture
stenting of biliary truct
title USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE
title_full USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE
title_fullStr USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE
title_full_unstemmed USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE
title_short USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE
title_sort use of covered self expandable nitinol stent for anastomotic biliary structure management after liver transplantation the first experience
topic complications of liver transplantation
biliary stricture
stenting of biliary truct
url https://journal.transpl.ru/vtio/article/view/99
work_keys_str_mv AT mnkornilov useofcoveredselfexpandablenitinolstentforanastomoticbiliarystructuremanagementafterlivertransplantationthefirstexperience
AT vvgvozdik useofcoveredselfexpandablenitinolstentforanastomoticbiliarystructuremanagementafterlivertransplantationthefirstexperience
AT anlotov useofcoveredselfexpandablenitinolstentforanastomoticbiliarystructuremanagementafterlivertransplantationthefirstexperience
AT ygmoysyuk useofcoveredselfexpandablenitinolstentforanastomoticbiliarystructuremanagementafterlivertransplantationthefirstexperience