Calculation Models for Acoustic Analysis of St. Elizabeth of Hungary Church in Jaworzno Szczakowa

In parallel with research conducted using conventional methods, a uniform index method for assessing the acoustic quality of Roman Catholic churches has been developed. The latest version of the index method has been created using the index observation matrix of 12 churches which have been rated by...

Full description

Saved in:
Bibliographic Details
Main Author: Krzysztof KOSAŁA
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2016-03-01
Series:Archives of Acoustics
Subjects:
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/1695
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849318565627297792
author Krzysztof KOSAŁA
author_facet Krzysztof KOSAŁA
author_sort Krzysztof KOSAŁA
collection DOAJ
description In parallel with research conducted using conventional methods, a uniform index method for assessing the acoustic quality of Roman Catholic churches has been developed. The latest version of the index method has been created using the index observation matrix of 12 churches which have been rated by means of the single number global index. Assessments of the acoustic quality of any Roman Catholic church, using two calculation models: the Global Acoustic Properties Index (GAP) and the Global Index (GI), are shown in the article. The verification was performed on the example of one church, showing the way of calculating global indices to assess the acoustic quality of a new facility. The next stages in the development of the index method for assessing the acoustic quality of churches were taking into account the audience, using simulation tests and determining the spatial distribution of the single number GAP index in an examined church. An attempt to use the GAP and GI calculation models to assess the acoustic properties of some churches is also shown in the article.
format Article
id doaj-art-6d5bafdcbf0b40dbb7cbd77f7ba3560e
institution Kabale University
issn 0137-5075
2300-262X
language English
publishDate 2016-03-01
publisher Institute of Fundamental Technological Research Polish Academy of Sciences
record_format Article
series Archives of Acoustics
spelling doaj-art-6d5bafdcbf0b40dbb7cbd77f7ba3560e2025-08-20T03:50:48ZengInstitute of Fundamental Technological Research Polish Academy of SciencesArchives of Acoustics0137-50752300-262X2016-03-0141310.1515/aoa-2016-0047Calculation Models for Acoustic Analysis of St. Elizabeth of Hungary Church in Jaworzno SzczakowaKrzysztof KOSAŁA0AGH University of Science and TechnologyIn parallel with research conducted using conventional methods, a uniform index method for assessing the acoustic quality of Roman Catholic churches has been developed. The latest version of the index method has been created using the index observation matrix of 12 churches which have been rated by means of the single number global index. Assessments of the acoustic quality of any Roman Catholic church, using two calculation models: the Global Acoustic Properties Index (GAP) and the Global Index (GI), are shown in the article. The verification was performed on the example of one church, showing the way of calculating global indices to assess the acoustic quality of a new facility. The next stages in the development of the index method for assessing the acoustic quality of churches were taking into account the audience, using simulation tests and determining the spatial distribution of the single number GAP index in an examined church. An attempt to use the GAP and GI calculation models to assess the acoustic properties of some churches is also shown in the article.https://acoustics.ippt.pan.pl/index.php/aa/article/view/1695acoustic qualityindex methodchurch acousticsSingular Value Decomposition (SVD)acoustic simulation tests.
spellingShingle Krzysztof KOSAŁA
Calculation Models for Acoustic Analysis of St. Elizabeth of Hungary Church in Jaworzno Szczakowa
Archives of Acoustics
acoustic quality
index method
church acoustics
Singular Value Decomposition (SVD)
acoustic simulation tests.
title Calculation Models for Acoustic Analysis of St. Elizabeth of Hungary Church in Jaworzno Szczakowa
title_full Calculation Models for Acoustic Analysis of St. Elizabeth of Hungary Church in Jaworzno Szczakowa
title_fullStr Calculation Models for Acoustic Analysis of St. Elizabeth of Hungary Church in Jaworzno Szczakowa
title_full_unstemmed Calculation Models for Acoustic Analysis of St. Elizabeth of Hungary Church in Jaworzno Szczakowa
title_short Calculation Models for Acoustic Analysis of St. Elizabeth of Hungary Church in Jaworzno Szczakowa
title_sort calculation models for acoustic analysis of st elizabeth of hungary church in jaworzno szczakowa
topic acoustic quality
index method
church acoustics
Singular Value Decomposition (SVD)
acoustic simulation tests.
url https://acoustics.ippt.pan.pl/index.php/aa/article/view/1695
work_keys_str_mv AT krzysztofkosała calculationmodelsforacousticanalysisofstelizabethofhungarychurchinjaworznoszczakowa