Experimental Investigation on Liquid Separation Equipment of Outdoor Heat Exchanger
The uneven distribution of refrigerants is a key issue in outdoor heat exchanger research. In this study, two types of baffles were designed, and a total of seven samples were prepared and placed in the heat exchanger header for experimental research. Through experiments, the refrigerant distributio...
Saved in:
| Main Authors: | Chen Hanbing, Li Wanyong, Chen Chaohua, Chen Tao, Shi Junye, Liu Yusheng, Chen Jiangping |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2021-01-01
|
| Series: | Zhileng xuebao |
| Subjects: | |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2021.03.077 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Study of the Frosting Factor Based on Finned-tube Heat Exchanger of Air-source Heat Pump
by: Han Xing, et al.
Published: (2014-01-01) -
Technology Development and Performance Improvement of CO2 Automobile Heat Pump Air-conditioning System
by: Wang Dandong, et al.
Published: (2018-01-01) -
Experimental Research on the Heating Performance of Waste Heat Recovery CO2 Heat Pumps for Electric Vehicles
by: Yuan Haorui, et al.
Published: (2023-01-01) -
Effects of Defrost-Initiation Criteria and Orientations of an Outdoor Heat Exchanger on the Performance of an Automotive Reversible CO<sub>2</sub> Heat Pump
by: Wenying Zhang, et al.
Published: (2025-04-01) -
Review and Potential Analysis of R1234yf Heat Pump Technology
by: Liu Yusheng, et al.
Published: (2020-01-01)