APPLICATION OF SOLID-STATE TRACK DETECTORS FOR MEASUREMENT OF THE LOW-LEVEL ACTIVITY OF ALPHA-EMITTERS

Alpha spectrometry approach using solid state nuclear track detectors  of CR-39 type is considered within the energy range 4-6 MeV. Experimental information obtaining stages are described from solid state nuclear track detectors  irradiation procedure to follow analysis of individual tracks. Results...

Full description

Saved in:
Bibliographic Details
Main Author: S. G. Gorbachev
Format: Article
Language:English
Published: Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev 2016-06-01
Series:Радиационная гигиена
Subjects:
Online Access:https://www.radhyg.ru/jour/article/view/401
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849240218801012736
author S. G. Gorbachev
author_facet S. G. Gorbachev
author_sort S. G. Gorbachev
collection DOAJ
description Alpha spectrometry approach using solid state nuclear track detectors  of CR-39 type is considered within the energy range 4-6 MeV. Experimental information obtaining stages are described from solid state nuclear track detectors  irradiation procedure to follow analysis of individual tracks. Results of plutonium isotopes contained samples and dependence of minimal detectible activity from exposure time and spike (tracer) activity for nuclide are presented.
format Article
id doaj-art-6c72e04b04eb43fa8ff1bce848399b32
institution Kabale University
issn 1998-426X
language English
publishDate 2016-06-01
publisher Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
record_format Article
series Радиационная гигиена
spelling doaj-art-6c72e04b04eb43fa8ff1bce848399b322025-08-20T04:00:40ZengSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. RamzaevРадиационная гигиена1998-426X2016-06-01225356390APPLICATION OF SOLID-STATE TRACK DETECTORS FOR MEASUREMENT OF THE LOW-LEVEL ACTIVITY OF ALPHA-EMITTERSS. G. Gorbachev0Radiation Protection InstituteAlpha spectrometry approach using solid state nuclear track detectors  of CR-39 type is considered within the energy range 4-6 MeV. Experimental information obtaining stages are described from solid state nuclear track detectors  irradiation procedure to follow analysis of individual tracks. Results of plutonium isotopes contained samples and dependence of minimal detectible activity from exposure time and spike (tracer) activity for nuclide are presented.https://www.radhyg.ru/jour/article/view/401solid-state nuclear detectopassive detectorscr-39processing images of tracksirradiation proceduremda
spellingShingle S. G. Gorbachev
APPLICATION OF SOLID-STATE TRACK DETECTORS FOR MEASUREMENT OF THE LOW-LEVEL ACTIVITY OF ALPHA-EMITTERS
Радиационная гигиена
solid-state nuclear detecto
passive detectors
cr-39
processing images of tracks
irradiation procedure
mda
title APPLICATION OF SOLID-STATE TRACK DETECTORS FOR MEASUREMENT OF THE LOW-LEVEL ACTIVITY OF ALPHA-EMITTERS
title_full APPLICATION OF SOLID-STATE TRACK DETECTORS FOR MEASUREMENT OF THE LOW-LEVEL ACTIVITY OF ALPHA-EMITTERS
title_fullStr APPLICATION OF SOLID-STATE TRACK DETECTORS FOR MEASUREMENT OF THE LOW-LEVEL ACTIVITY OF ALPHA-EMITTERS
title_full_unstemmed APPLICATION OF SOLID-STATE TRACK DETECTORS FOR MEASUREMENT OF THE LOW-LEVEL ACTIVITY OF ALPHA-EMITTERS
title_short APPLICATION OF SOLID-STATE TRACK DETECTORS FOR MEASUREMENT OF THE LOW-LEVEL ACTIVITY OF ALPHA-EMITTERS
title_sort application of solid state track detectors for measurement of the low level activity of alpha emitters
topic solid-state nuclear detecto
passive detectors
cr-39
processing images of tracks
irradiation procedure
mda
url https://www.radhyg.ru/jour/article/view/401
work_keys_str_mv AT sggorbachev applicationofsolidstatetrackdetectorsformeasurementofthelowlevelactivityofalphaemitters