A Modified DOE-2 Model for Typical Performance of Absorption Chillers and its Application

LiBr-water absorption chillers are commonly adopted in multifunction energy systems. The empirical part-load performance model for chillers presented by DOE-2 is one of the analytical methods to solve chiller performances. In this study, the applicability of the DOE-2 model for absorption chillers w...

Full description

Saved in:
Bibliographic Details
Main Authors: 杨承, 杨泽亮, 蔡睿贤
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2007-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2007.06.010
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850232853067988992
author 杨承
杨泽亮
蔡睿贤
author_facet 杨承
杨泽亮
蔡睿贤
author_sort 杨承
collection DOAJ
description LiBr-water absorption chillers are commonly adopted in multifunction energy systems. The empirical part-load performance model for chillers presented by DOE-2 is one of the analytical methods to solve chiller performances. In this study, the applicability of the DOE-2 model for absorption chillers was analyzed. A modified DOE-2 model for double effect steam-driven absorption chillers, as an example, was developed and its reasonability and validity were tested by the product data and the general theoretical model. Application case study confirms the ability of the modified DOE-2 model to fast predict the part-load performances of absorption chillers.
format Article
id doaj-art-6bf6e53a2fc84b01b41549aa9820a5a3
institution OA Journals
issn 0253-4339
language zho
publishDate 2007-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-6bf6e53a2fc84b01b41549aa9820a5a32025-08-20T02:03:04ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392007-01-0166522833A Modified DOE-2 Model for Typical Performance of Absorption Chillers and its Application杨承杨泽亮蔡睿贤LiBr-water absorption chillers are commonly adopted in multifunction energy systems. The empirical part-load performance model for chillers presented by DOE-2 is one of the analytical methods to solve chiller performances. In this study, the applicability of the DOE-2 model for absorption chillers was analyzed. A modified DOE-2 model for double effect steam-driven absorption chillers, as an example, was developed and its reasonability and validity were tested by the product data and the general theoretical model. Application case study confirms the ability of the modified DOE-2 model to fast predict the part-load performances of absorption chillers.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2007.06.010engineering thermophysicsLiBr-water absorption chillerAnalytical methodPart-load performance
spellingShingle 杨承
杨泽亮
蔡睿贤
A Modified DOE-2 Model for Typical Performance of Absorption Chillers and its Application
Zhileng xuebao
engineering thermophysics
LiBr-water absorption chiller
Analytical method
Part-load performance
title A Modified DOE-2 Model for Typical Performance of Absorption Chillers and its Application
title_full A Modified DOE-2 Model for Typical Performance of Absorption Chillers and its Application
title_fullStr A Modified DOE-2 Model for Typical Performance of Absorption Chillers and its Application
title_full_unstemmed A Modified DOE-2 Model for Typical Performance of Absorption Chillers and its Application
title_short A Modified DOE-2 Model for Typical Performance of Absorption Chillers and its Application
title_sort modified doe 2 model for typical performance of absorption chillers and its application
topic engineering thermophysics
LiBr-water absorption chiller
Analytical method
Part-load performance
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2007.06.010
work_keys_str_mv AT yángchéng amodifieddoe2modelfortypicalperformanceofabsorptionchillersanditsapplication
AT yángzéliàng amodifieddoe2modelfortypicalperformanceofabsorptionchillersanditsapplication
AT càiruìxián amodifieddoe2modelfortypicalperformanceofabsorptionchillersanditsapplication