High Energy X-Ray Detection by MicroPattern Gaseous Detector

Purpose: The paper aims to discuss the response of the Micro-Mesh Gaseous Structure (Micromegas) detector to high-energy X-ray with 2.3 MeV energy using photon to neutron converters in addition to optimization of the detector components by Monte Carlo simulation. Materials and Methods: Methods o...

Full description

Saved in:
Bibliographic Details
Main Authors: Saeedeh Khezripour, Mohammad Reza Rezai Rayeni
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2025-01-01
Series:Frontiers in Biomedical Technologies
Subjects:
Online Access:https://fbt.tums.ac.ir/index.php/fbt/article/view/1052
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823863921089445888
author Saeedeh Khezripour
Mohammad Reza Rezai Rayeni
author_facet Saeedeh Khezripour
Mohammad Reza Rezai Rayeni
author_sort Saeedeh Khezripour
collection DOAJ
description Purpose: The paper aims to discuss the response of the Micro-Mesh Gaseous Structure (Micromegas) detector to high-energy X-ray with 2.3 MeV energy using photon to neutron converters in addition to optimization of the detector components by Monte Carlo simulation. Materials and Methods: Methods of using Micromegas are different in terms of energy and intensity of high-energy X-ray. Response of Micromegas detector to X-ray with 2.3 MeV by different photoneutron converters was calculated by Monte Carlo N Particle X-Version (MCNPX) code. The number of electrons in the drift and multiplication regions and the depth-dose in the various regions of the detector were measured to study the response of the Micromegas detector to high energy X-ray. Also, the thickness of the upper electrode, and the type of gas in the detector were studied and optimized. Results: D2O with 2×10-5 efficiency is the best target to convert photons with 2.3 MeV energy to neutrons. It is the proper convertor to change the high energy X-ray into a photoneutron that can be detected by Micromegas. The optimum thickness of the upper electrode is 0.0026 cm for air and P10 gas in the detector. Conclusion: The results show that this detector can detect high-energy X-rays with energy above 2 MeV. The Monte Carlo results showed the output current of the Micromegas detector is 5.12 pA per one input hard X-ray photon.
format Article
id doaj-art-6b44844f0d31474abde96a46413ac0b3
institution Kabale University
issn 2345-5837
language English
publishDate 2025-01-01
publisher Tehran University of Medical Sciences
record_format Article
series Frontiers in Biomedical Technologies
spelling doaj-art-6b44844f0d31474abde96a46413ac0b32025-02-09T08:55:51ZengTehran University of Medical SciencesFrontiers in Biomedical Technologies2345-58372025-01-0112110.18502/fbt.v12i1.17742High Energy X-Ray Detection by MicroPattern Gaseous DetectorSaeedeh Khezripour0Mohammad Reza Rezai Rayeni1Department of Molecular and Atomic Physics, Faculty of Modern Science and Technology, Graduate University of Advanced Technology, Kerman, IranDepartment of Nuclear Engineering, Faculty of Modern Sciences and Technologies, Graduate University of Advanced Technology, Kerman, Iran Purpose: The paper aims to discuss the response of the Micro-Mesh Gaseous Structure (Micromegas) detector to high-energy X-ray with 2.3 MeV energy using photon to neutron converters in addition to optimization of the detector components by Monte Carlo simulation. Materials and Methods: Methods of using Micromegas are different in terms of energy and intensity of high-energy X-ray. Response of Micromegas detector to X-ray with 2.3 MeV by different photoneutron converters was calculated by Monte Carlo N Particle X-Version (MCNPX) code. The number of electrons in the drift and multiplication regions and the depth-dose in the various regions of the detector were measured to study the response of the Micromegas detector to high energy X-ray. Also, the thickness of the upper electrode, and the type of gas in the detector were studied and optimized. Results: D2O with 2×10-5 efficiency is the best target to convert photons with 2.3 MeV energy to neutrons. It is the proper convertor to change the high energy X-ray into a photoneutron that can be detected by Micromegas. The optimum thickness of the upper electrode is 0.0026 cm for air and P10 gas in the detector. Conclusion: The results show that this detector can detect high-energy X-rays with energy above 2 MeV. The Monte Carlo results showed the output current of the Micromegas detector is 5.12 pA per one input hard X-ray photon. https://fbt.tums.ac.ir/index.php/fbt/article/view/1052High Energy X-RayGas DetectorMicromegasD2OPhotoneutronMonte Carlo N Particle X-Version Code
spellingShingle Saeedeh Khezripour
Mohammad Reza Rezai Rayeni
High Energy X-Ray Detection by MicroPattern Gaseous Detector
Frontiers in Biomedical Technologies
High Energy X-Ray
Gas Detector
Micromegas
D2O
Photoneutron
Monte Carlo N Particle X-Version Code
title High Energy X-Ray Detection by MicroPattern Gaseous Detector
title_full High Energy X-Ray Detection by MicroPattern Gaseous Detector
title_fullStr High Energy X-Ray Detection by MicroPattern Gaseous Detector
title_full_unstemmed High Energy X-Ray Detection by MicroPattern Gaseous Detector
title_short High Energy X-Ray Detection by MicroPattern Gaseous Detector
title_sort high energy x ray detection by micropattern gaseous detector
topic High Energy X-Ray
Gas Detector
Micromegas
D2O
Photoneutron
Monte Carlo N Particle X-Version Code
url https://fbt.tums.ac.ir/index.php/fbt/article/view/1052
work_keys_str_mv AT saeedehkhezripour highenergyxraydetectionbymicropatterngaseousdetector
AT mohammadrezarezairayeni highenergyxraydetectionbymicropatterngaseousdetector