Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities

Medical devices are sterilized before being used for invasive clinical procedures such as surgery, to prevent pathogen transfer. Failure to sterilize medical devices properly presents a risk of healthcare-associated infections. Studies and reports have indicated that inadequately sterilized medical...

Full description

Saved in:
Bibliographic Details
Main Authors: Gopal Panta, Ann K Richardson, Ian C Shaw
Format: Article
Language:English
Published: The Journal of Infection in Developing Countries 2019-10-01
Series:Journal of Infection in Developing Countries
Subjects:
Online Access:https://jidc.org/index.php/journal/article/view/11433
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850148228219011072
author Gopal Panta
Ann K Richardson
Ian C Shaw
author_facet Gopal Panta
Ann K Richardson
Ian C Shaw
author_sort Gopal Panta
collection DOAJ
description Medical devices are sterilized before being used for invasive clinical procedures such as surgery, to prevent pathogen transfer. Failure to sterilize medical devices properly presents a risk of healthcare-associated infections. Studies and reports have indicated that inadequately sterilized medical devices are one of the causes of a higher rate of healthcare-associated infections in developing countries. Steam sterilization (autoclaving) is the most widely used method for sterilization and is considered the most robust and cost-effective method for sterilization of medical devices. The effectiveness of steam sterilization can be measured using biological indicators. A literature search was undertaken to understand the effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities across the globe. Studies using biological indicators for measuring the effectiveness of autoclaving were obtained. Failures of steam sterilization practices were identified and discussed as a means of identifying factors that might be associated with the ineffectiveness of steam sterilization practices between different countries. The number of studies measuring the effectiveness of steam sterilization is small, and few evaluate the effectiveness of steam sterilization specifically in developing countries. There are fewer studies on higher level healthcare facilities than dental facilities. More evidence about the effectiveness of autoclaving in healthcare facilities is needed to draw firm conclusions, but the data suggest that there are inadequacies in autoclave procedures and operator education.
format Article
id doaj-art-6afa4cd827584829b7f8eb017f2d91d7
institution OA Journals
issn 1972-2680
language English
publishDate 2019-10-01
publisher The Journal of Infection in Developing Countries
record_format Article
series Journal of Infection in Developing Countries
spelling doaj-art-6afa4cd827584829b7f8eb017f2d91d72025-08-20T02:27:18ZengThe Journal of Infection in Developing CountriesJournal of Infection in Developing Countries1972-26802019-10-01131010.3855/jidc.11433Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilitiesGopal Panta0Ann K Richardson1Ian C Shaw2School of Health Sciences, University of Canterbury, Christchurch, New ZealandSchool of Health Sciences, University of Canterbury, Christchurch, New ZealandSchool of Physical and Chemical Sciences, University of Canterbury, Christchurch, New Zealand Medical devices are sterilized before being used for invasive clinical procedures such as surgery, to prevent pathogen transfer. Failure to sterilize medical devices properly presents a risk of healthcare-associated infections. Studies and reports have indicated that inadequately sterilized medical devices are one of the causes of a higher rate of healthcare-associated infections in developing countries. Steam sterilization (autoclaving) is the most widely used method for sterilization and is considered the most robust and cost-effective method for sterilization of medical devices. The effectiveness of steam sterilization can be measured using biological indicators. A literature search was undertaken to understand the effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities across the globe. Studies using biological indicators for measuring the effectiveness of autoclaving were obtained. Failures of steam sterilization practices were identified and discussed as a means of identifying factors that might be associated with the ineffectiveness of steam sterilization practices between different countries. The number of studies measuring the effectiveness of steam sterilization is small, and few evaluate the effectiveness of steam sterilization specifically in developing countries. There are fewer studies on higher level healthcare facilities than dental facilities. More evidence about the effectiveness of autoclaving in healthcare facilities is needed to draw firm conclusions, but the data suggest that there are inadequacies in autoclave procedures and operator education. https://jidc.org/index.php/journal/article/view/11433Steam Sterilizationbiological indicatorshealthcare-associated infectionsevaluation
spellingShingle Gopal Panta
Ann K Richardson
Ian C Shaw
Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities
Journal of Infection in Developing Countries
Steam Sterilization
biological indicators
healthcare-associated infections
evaluation
title Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities
title_full Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities
title_fullStr Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities
title_full_unstemmed Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities
title_short Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities
title_sort effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities
topic Steam Sterilization
biological indicators
healthcare-associated infections
evaluation
url https://jidc.org/index.php/journal/article/view/11433
work_keys_str_mv AT gopalpanta effectivenessofautoclavinginsterilizingreusablemedicaldevicesinhealthcarefacilities
AT annkrichardson effectivenessofautoclavinginsterilizingreusablemedicaldevicesinhealthcarefacilities
AT iancshaw effectivenessofautoclavinginsterilizingreusablemedicaldevicesinhealthcarefacilities