The dependence of the internal electrical resistance of the cable rubber rope on the presence of a cable rupture

Problems. The introduction of steel reinforced concrete coatings of structures, in our opinion, is preceded by the development of methods for monitoring the state of cable-stayed ropes - creating safe conditions for long-term operation of structures. The aim of the study. Analytical determinatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Іван Бельмас, Олена Білоус, Ганна Танцура, Ангеліна Швачка
Format: Article
Language:English
Published: National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute" 2022-06-01
Series:Mechanics and Advanced Technologies
Subjects:
Online Access:http://journal.mmi.kpi.ua/article/view/250801
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850055107359539200
author Іван Бельмас
Олена Білоус
Ганна Танцура
Ангеліна Швачка
author_facet Іван Бельмас
Олена Білоус
Ганна Танцура
Ангеліна Швачка
author_sort Іван Бельмас
collection DOAJ
description Problems. The introduction of steel reinforced concrete coatings of structures, in our opinion, is preceded by the development of methods for monitoring the state of cable-stayed ropes - creating safe conditions for long-term operation of structures. The aim of the study. Analytical determination of the dependence of the internal electrical resistance of a cable-stayed rubber cable rope on the presence of a cable rupture. Methods of implementation. To control all cables, the system must provide alternate monitoring of the electrical resistances of the circuits formed by the cables, compare them with reference values, and issue a signal regarding the condition of the rope. It should be designed on the basis of the following data: the type and design of the cable-stayed rope, its length, the number and layout of the cables in the rope, the ability to access one or both of its ends, the electrical properties of the cables and rubber, the resistance values ​​of the cables for all schemes of their determination. Research results. Requirements for the automatic control system of the cable-stayed rubber cord rope. The regularity of the dependence of the electrical resistance of the cable-stayed rope on the burst of an arbitrary cable. Possibility of automatic control of the state of the rubber-cable cable-stayed rope. Conclusions. The results obtained can be considered quite reliable, since the equations obtained on the basis of the fundamental provisions of electrical engineering are obtained analytically in a closed form. Experimental studies have established that the internal electrical resistance of the rope cables depends on its properties and the presence or absence of damage to the cables. The rope includes a number of cables. Any cable can be damaged.
format Article
id doaj-art-69c319cc283340909a6afb63df5a3c1e
institution DOAJ
issn 2521-1943
2522-4255
language English
publishDate 2022-06-01
publisher National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute"
record_format Article
series Mechanics and Advanced Technologies
spelling doaj-art-69c319cc283340909a6afb63df5a3c1e2025-08-20T02:52:03ZengNational Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute"Mechanics and Advanced Technologies2521-19432522-42552022-06-016110.20535/2521-1943.2022.6.1.250801The dependence of the internal electrical resistance of the cable rubber rope on the presence of a cable ruptureІван Бельмас0Олена Білоус1Ганна Танцура2Ангеліна Швачка3Faculty of Mechanical Engineering, Department of Mechanical Engineering TechnologyDniprovs'kyi state technical universityDniprovs'kyi state technical universityDniprovs'kyi state technical university Problems. The introduction of steel reinforced concrete coatings of structures, in our opinion, is preceded by the development of methods for monitoring the state of cable-stayed ropes - creating safe conditions for long-term operation of structures. The aim of the study. Analytical determination of the dependence of the internal electrical resistance of a cable-stayed rubber cable rope on the presence of a cable rupture. Methods of implementation. To control all cables, the system must provide alternate monitoring of the electrical resistances of the circuits formed by the cables, compare them with reference values, and issue a signal regarding the condition of the rope. It should be designed on the basis of the following data: the type and design of the cable-stayed rope, its length, the number and layout of the cables in the rope, the ability to access one or both of its ends, the electrical properties of the cables and rubber, the resistance values ​​of the cables for all schemes of their determination. Research results. Requirements for the automatic control system of the cable-stayed rubber cord rope. The regularity of the dependence of the electrical resistance of the cable-stayed rope on the burst of an arbitrary cable. Possibility of automatic control of the state of the rubber-cable cable-stayed rope. Conclusions. The results obtained can be considered quite reliable, since the equations obtained on the basis of the fundamental provisions of electrical engineering are obtained analytically in a closed form. Experimental studies have established that the internal electrical resistance of the rope cables depends on its properties and the presence or absence of damage to the cables. The rope includes a number of cables. Any cable can be damaged. http://journal.mmi.kpi.ua/article/view/250801rubber ropeelectrical resistancecontrolcable ropemathematical modelsignal
spellingShingle Іван Бельмас
Олена Білоус
Ганна Танцура
Ангеліна Швачка
The dependence of the internal electrical resistance of the cable rubber rope on the presence of a cable rupture
Mechanics and Advanced Technologies
rubber rope
electrical resistance
control
cable rope
mathematical model
signal
title The dependence of the internal electrical resistance of the cable rubber rope on the presence of a cable rupture
title_full The dependence of the internal electrical resistance of the cable rubber rope on the presence of a cable rupture
title_fullStr The dependence of the internal electrical resistance of the cable rubber rope on the presence of a cable rupture
title_full_unstemmed The dependence of the internal electrical resistance of the cable rubber rope on the presence of a cable rupture
title_short The dependence of the internal electrical resistance of the cable rubber rope on the presence of a cable rupture
title_sort dependence of the internal electrical resistance of the cable rubber rope on the presence of a cable rupture
topic rubber rope
electrical resistance
control
cable rope
mathematical model
signal
url http://journal.mmi.kpi.ua/article/view/250801
work_keys_str_mv AT ívanbelʹmas thedependenceoftheinternalelectricalresistanceofthecablerubberropeonthepresenceofacablerupture
AT olenabílous thedependenceoftheinternalelectricalresistanceofthecablerubberropeonthepresenceofacablerupture
AT gannatancura thedependenceoftheinternalelectricalresistanceofthecablerubberropeonthepresenceofacablerupture
AT angelínašvačka thedependenceoftheinternalelectricalresistanceofthecablerubberropeonthepresenceofacablerupture
AT ívanbelʹmas dependenceoftheinternalelectricalresistanceofthecablerubberropeonthepresenceofacablerupture
AT olenabílous dependenceoftheinternalelectricalresistanceofthecablerubberropeonthepresenceofacablerupture
AT gannatancura dependenceoftheinternalelectricalresistanceofthecablerubberropeonthepresenceofacablerupture
AT angelínašvačka dependenceoftheinternalelectricalresistanceofthecablerubberropeonthepresenceofacablerupture