Response Surface Method for Design of Room Air Conditioner Heat Exchangers with Decreasing Tube Diameter
The response surface method is applied to design the heat exchanger with decreasing tube diameter, for the traditional design methods are not suitable for the optimization of the performance and cost of heat exchanger simultaneously. The method fits the relationship among the tube length, fin pitch,...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2011-01-01
|
| Series: | Zhileng xuebao |
| Subjects: | |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2011.05.047 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850027345656676352 |
|---|---|
| author | Wu Zhaoguo Ren Tao Ding Guoliang Hu Haitao Zheng Yongxin Gao Yifeng |
| author_facet | Wu Zhaoguo Ren Tao Ding Guoliang Hu Haitao Zheng Yongxin Gao Yifeng |
| author_sort | Wu Zhaoguo |
| collection | DOAJ |
| description | The response surface method is applied to design the heat exchanger with decreasing tube diameter, for the traditional design methods are not suitable for the optimization of the performance and cost of heat exchanger simultaneously. The method fits the relationship among the tube length, fin pitch, performance and cost of heat exchanger into a quadratic continuous function that can be solved directly. The accuracy of the method is verified by applying it to the optimization of 7mm tube heat exchanger, the deviation from the experimental data is 0.3%. Using the method for the optimization of 9.52mm tube heat exchanger into 5mm tube heat exchanger, the cost and refrigeration charge of designed heat exchanger decrease by 28% and 39.8%, respectively, while the performance is unchanged. |
| format | Article |
| id | doaj-art-69a34b5b23c04ed0b50ad2439bbd8bef |
| institution | DOAJ |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2011-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-69a34b5b23c04ed0b50ad2439bbd8bef2025-08-20T03:00:13ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392011-01-013266520437Response Surface Method for Design of Room Air Conditioner Heat Exchangers with Decreasing Tube DiameterWu ZhaoguoRen TaoDing GuoliangHu HaitaoZheng YongxinGao YifengThe response surface method is applied to design the heat exchanger with decreasing tube diameter, for the traditional design methods are not suitable for the optimization of the performance and cost of heat exchanger simultaneously. The method fits the relationship among the tube length, fin pitch, performance and cost of heat exchanger into a quadratic continuous function that can be solved directly. The accuracy of the method is verified by applying it to the optimization of 7mm tube heat exchanger, the deviation from the experimental data is 0.3%. Using the method for the optimization of 9.52mm tube heat exchanger into 5mm tube heat exchanger, the cost and refrigeration charge of designed heat exchanger decrease by 28% and 39.8%, respectively, while the performance is unchanged.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2011.05.047pyrologyRefrigeration and cryogenicsroom air conditionerResponse surface methodTube diameterdesign |
| spellingShingle | Wu Zhaoguo Ren Tao Ding Guoliang Hu Haitao Zheng Yongxin Gao Yifeng Response Surface Method for Design of Room Air Conditioner Heat Exchangers with Decreasing Tube Diameter Zhileng xuebao pyrology Refrigeration and cryogenics room air conditioner Response surface method Tube diameter design |
| title | Response Surface Method for Design of Room Air Conditioner Heat Exchangers with Decreasing Tube Diameter |
| title_full | Response Surface Method for Design of Room Air Conditioner Heat Exchangers with Decreasing Tube Diameter |
| title_fullStr | Response Surface Method for Design of Room Air Conditioner Heat Exchangers with Decreasing Tube Diameter |
| title_full_unstemmed | Response Surface Method for Design of Room Air Conditioner Heat Exchangers with Decreasing Tube Diameter |
| title_short | Response Surface Method for Design of Room Air Conditioner Heat Exchangers with Decreasing Tube Diameter |
| title_sort | response surface method for design of room air conditioner heat exchangers with decreasing tube diameter |
| topic | pyrology Refrigeration and cryogenics room air conditioner Response surface method Tube diameter design |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2011.05.047 |
| work_keys_str_mv | AT wuzhaoguo responsesurfacemethodfordesignofroomairconditionerheatexchangerswithdecreasingtubediameter AT rentao responsesurfacemethodfordesignofroomairconditionerheatexchangerswithdecreasingtubediameter AT dingguoliang responsesurfacemethodfordesignofroomairconditionerheatexchangerswithdecreasingtubediameter AT huhaitao responsesurfacemethodfordesignofroomairconditionerheatexchangerswithdecreasingtubediameter AT zhengyongxin responsesurfacemethodfordesignofroomairconditionerheatexchangerswithdecreasingtubediameter AT gaoyifeng responsesurfacemethodfordesignofroomairconditionerheatexchangerswithdecreasingtubediameter |