Stability Evaluation of Non-ideal Grid-tied Photovoltaic on IEEE-9 Bus System

The integration of photovoltaic in power systems has proved its capability of being a viable source of power to be considered in grid-tied power systems. However, in some cases various electrical challenges may arise when high photovoltaic power is integrated into power systems at the time the volt...

Full description

Saved in:
Bibliographic Details
Main Authors: S. D. Lumina, M. E. S. Mnguni, Y. D. Mfoumboulou
Format: Article
Language:English
Published: Penerbit Universiti Teknikal Malaysia Melaka 2023-10-01
Series:International Journal of Electrical Engineering and Applied Sciences
Online Access:https://ijeeas.utem.edu.my/ijeeas/article/view/6156
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849340369094836224
author S. D. Lumina
M. E. S. Mnguni
Y. D. Mfoumboulou
author_facet S. D. Lumina
M. E. S. Mnguni
Y. D. Mfoumboulou
author_sort S. D. Lumina
collection DOAJ
description The integration of photovoltaic in power systems has proved its capability of being a viable source of power to be considered in grid-tied power systems. However, in some cases various electrical challenges may arise when high photovoltaic power is integrated into power systems at the time the voltage collapse caused by an increase in the load consumption. In case of non-ideal grid-tied photovoltaic due to inappropriate or absence of control strategies to regulate the power dispatch between the microgrid and the grid, the photovoltaic power may negatively further affect the grid voltage stability instead of restoring it to the stability level of the electrical grid. This paper investigates the challenge of solar power integration in the grid by demonstrating that due to its randomness and intermittent nature, the photovoltaic power is likely to be associated with voltage disturbance and low power quality that occurs on the electrical grid. Data from simulation of a non-ideal grid-tied photovoltaic are collected to demonstrate the characteristics and negative effects of high photovoltaic integration on the IEEE-9 bus system.
format Article
id doaj-art-69324119f06c402eb12e77850ae560ec
institution Kabale University
issn 2600-7495
2600-9633
language English
publishDate 2023-10-01
publisher Penerbit Universiti Teknikal Malaysia Melaka
record_format Article
series International Journal of Electrical Engineering and Applied Sciences
spelling doaj-art-69324119f06c402eb12e77850ae560ec2025-08-20T03:43:55ZengPenerbit Universiti Teknikal Malaysia MelakaInternational Journal of Electrical Engineering and Applied Sciences2600-74952600-96332023-10-016210.54554/ijeeas.2023.6.02.002Stability Evaluation of Non-ideal Grid-tied Photovoltaic on IEEE-9 Bus SystemS. D. Lumina0M. E. S. Mnguni1Y. D. Mfoumboulou Cape Peninsula University of TechnologyCape Peninsula University of Technology The integration of photovoltaic in power systems has proved its capability of being a viable source of power to be considered in grid-tied power systems. However, in some cases various electrical challenges may arise when high photovoltaic power is integrated into power systems at the time the voltage collapse caused by an increase in the load consumption. In case of non-ideal grid-tied photovoltaic due to inappropriate or absence of control strategies to regulate the power dispatch between the microgrid and the grid, the photovoltaic power may negatively further affect the grid voltage stability instead of restoring it to the stability level of the electrical grid. This paper investigates the challenge of solar power integration in the grid by demonstrating that due to its randomness and intermittent nature, the photovoltaic power is likely to be associated with voltage disturbance and low power quality that occurs on the electrical grid. Data from simulation of a non-ideal grid-tied photovoltaic are collected to demonstrate the characteristics and negative effects of high photovoltaic integration on the IEEE-9 bus system. https://ijeeas.utem.edu.my/ijeeas/article/view/6156
spellingShingle S. D. Lumina
M. E. S. Mnguni
Y. D. Mfoumboulou
Stability Evaluation of Non-ideal Grid-tied Photovoltaic on IEEE-9 Bus System
International Journal of Electrical Engineering and Applied Sciences
title Stability Evaluation of Non-ideal Grid-tied Photovoltaic on IEEE-9 Bus System
title_full Stability Evaluation of Non-ideal Grid-tied Photovoltaic on IEEE-9 Bus System
title_fullStr Stability Evaluation of Non-ideal Grid-tied Photovoltaic on IEEE-9 Bus System
title_full_unstemmed Stability Evaluation of Non-ideal Grid-tied Photovoltaic on IEEE-9 Bus System
title_short Stability Evaluation of Non-ideal Grid-tied Photovoltaic on IEEE-9 Bus System
title_sort stability evaluation of non ideal grid tied photovoltaic on ieee 9 bus system
url https://ijeeas.utem.edu.my/ijeeas/article/view/6156
work_keys_str_mv AT sdlumina stabilityevaluationofnonidealgridtiedphotovoltaiconieee9bussystem
AT mesmnguni stabilityevaluationofnonidealgridtiedphotovoltaiconieee9bussystem
AT ydmfoumboulou stabilityevaluationofnonidealgridtiedphotovoltaiconieee9bussystem