Characterizing Subjective Noisiness in Hospital Lobbies

The present study was conducted in the lobbies of 16 Taiwanese urban hospitals to establish what contributes to the degree of noisiness experienced by patients and those accompanying them. Noise level measurements were then conducted by 15 min equivalent sound pressure levels (LAeq, 15m, dB) during...

Full description

Saved in:
Bibliographic Details
Main Author: Chiung Yao CHEN
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2015-04-01
Series:Archives of Acoustics
Subjects:
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/1492
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849318562937700352
author Chiung Yao CHEN
author_facet Chiung Yao CHEN
author_sort Chiung Yao CHEN
collection DOAJ
description The present study was conducted in the lobbies of 16 Taiwanese urban hospitals to establish what contributes to the degree of noisiness experienced by patients and those accompanying them. Noise level measurements were then conducted by 15 min equivalent sound pressure levels (LAeq, 15m, dB) during daytime hours. The average LAeq itself was found to be poorly related to perceived noisiness. Levels variations were better correlated, more continual noise may actually be perceived as noisier. According to the findings of a multiple linear stepwise regression model (r = 0.91, R2 = 0.83), the 3 independent variables shown to have the largest effects on perceived noisiness were 1)  $1/(L_5−L_{95})$, 2) effective duration of the normalized autocorrelation function $(\tau_e, h)$, of all LAeq, 15m over 9–17, and 3) percentile loudness, N5, 15m. These results resemble previous studies that had assumed that a larger fluctuation of noise level corresponds to less annoyance experienced for mixed traffic noise studied in a laboratory situation. As an advanced approach, for hospital noise that consisted of 12 audible noise events, subjective noisiness were evaluated by the noise time structure analyzed by autocorrelation with loudness and levels variation.
format Article
id doaj-art-68dba1e610e54bdea9065088b7a18028
institution Kabale University
issn 0137-5075
2300-262X
language English
publishDate 2015-04-01
publisher Institute of Fundamental Technological Research Polish Academy of Sciences
record_format Article
series Archives of Acoustics
spelling doaj-art-68dba1e610e54bdea9065088b7a180282025-08-20T03:50:48ZengInstitute of Fundamental Technological Research Polish Academy of SciencesArchives of Acoustics0137-50752300-262X2015-04-0140210.1515/aoa-2015-0026Characterizing Subjective Noisiness in Hospital LobbiesChiung Yao CHEN0Dept. of Architecture, Chaoyang University of TechnologyThe present study was conducted in the lobbies of 16 Taiwanese urban hospitals to establish what contributes to the degree of noisiness experienced by patients and those accompanying them. Noise level measurements were then conducted by 15 min equivalent sound pressure levels (LAeq, 15m, dB) during daytime hours. The average LAeq itself was found to be poorly related to perceived noisiness. Levels variations were better correlated, more continual noise may actually be perceived as noisier. According to the findings of a multiple linear stepwise regression model (r = 0.91, R2 = 0.83), the 3 independent variables shown to have the largest effects on perceived noisiness were 1)  $1/(L_5−L_{95})$, 2) effective duration of the normalized autocorrelation function $(\tau_e, h)$, of all LAeq, 15m over 9–17, and 3) percentile loudness, N5, 15m. These results resemble previous studies that had assumed that a larger fluctuation of noise level corresponds to less annoyance experienced for mixed traffic noise studied in a laboratory situation. As an advanced approach, for hospital noise that consisted of 12 audible noise events, subjective noisiness were evaluated by the noise time structure analyzed by autocorrelation with loudness and levels variation.https://acoustics.ippt.pan.pl/index.php/aa/article/view/1492noisinesshospitalannoyanceloudnessautocorrection functionreverberation time.
spellingShingle Chiung Yao CHEN
Characterizing Subjective Noisiness in Hospital Lobbies
Archives of Acoustics
noisiness
hospital
annoyance
loudness
autocorrection function
reverberation time.
title Characterizing Subjective Noisiness in Hospital Lobbies
title_full Characterizing Subjective Noisiness in Hospital Lobbies
title_fullStr Characterizing Subjective Noisiness in Hospital Lobbies
title_full_unstemmed Characterizing Subjective Noisiness in Hospital Lobbies
title_short Characterizing Subjective Noisiness in Hospital Lobbies
title_sort characterizing subjective noisiness in hospital lobbies
topic noisiness
hospital
annoyance
loudness
autocorrection function
reverberation time.