Can we trust naked eye assessments of the capillary refill test in children? An experimental study

Abstract Background The capillary refill test is widely used in pediatric emergency medicine and critical care although its validity and reliability are debated. Naked eye estimation is the recommended method for capillary refill time (CR time) assessment. The goal of this study was to compare naked...

Full description

Saved in:
Bibliographic Details
Main Authors: Frida Meyer, Jonatan Stahre, Joakim Henricson, Daniel B. Wilhelms
Format: Article
Language:English
Published: BMC 2025-03-01
Series:BMC Emergency Medicine
Subjects:
Online Access:https://doi.org/10.1186/s12873-025-01204-0
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850063669789982720
author Frida Meyer
Jonatan Stahre
Joakim Henricson
Daniel B. Wilhelms
author_facet Frida Meyer
Jonatan Stahre
Joakim Henricson
Daniel B. Wilhelms
author_sort Frida Meyer
collection DOAJ
description Abstract Background The capillary refill test is widely used in pediatric emergency medicine and critical care although its validity and reliability are debated. Naked eye estimation is the recommended method for capillary refill time (CR time) assessment. The goal of this study was to compare naked eye estimations of the CR time in pediatric patients to quantified capillary refill time (qCR time) using polarized reflectance imaging as an objective reference, and to investigate interobserver and intra-observer consistency of naked eye assessments of CR time. Method A film sequence comprising videos of capillary refill tests from 15 emergency pediatric patients was shown under standardized conditions to 62 observers (pediatricians, nurses, assistant nurses, and medical secretaries). The observers’ estimations of CR time in seconds and in descriptive categorizations were compared to objectively derived qCR time. Three tests were shown twice without the observers’ knowledge. Results There was poor interobserver agreement in all professions, with limits of agreement ranging from 1.17 s (assistant nurses) to 2.00 s (secretaries). Intra-observer agreement for estimations of both time and descriptive categorizations was limited. The correlation between naked eye assessments and qCR time was weak. Conclusion This study shows that naked eye assessment of CR time in children is highly subjective with poor reproducibility in pediatric nurses and pediatricians, as well as in comparison to a quantitative method. Based on the lack of both inter- and intra-observer consistency in the assessments, these findings suggest that CR time assessed by naked eye should be questioned as a routine test in pediatric emergencies.
format Article
id doaj-art-68bbcf15206148ca840ad5572a3323f2
institution DOAJ
issn 1471-227X
language English
publishDate 2025-03-01
publisher BMC
record_format Article
series BMC Emergency Medicine
spelling doaj-art-68bbcf15206148ca840ad5572a3323f22025-08-20T02:49:31ZengBMCBMC Emergency Medicine1471-227X2025-03-012511910.1186/s12873-025-01204-0Can we trust naked eye assessments of the capillary refill test in children? An experimental studyFrida Meyer0Jonatan Stahre1Joakim Henricson2Daniel B. Wilhelms3Department of Emergency Medicine in Linköping, Department of Biomedical and Clinical Sciences, Linköping UniversityCrown Princess Victoria’s Child and Youth Hospital, Department of Biomedical and Clinical Sciences, Linköping UniversityDepartment of Emergency Medicine in Linköping, Department of Biomedical and Clinical Sciences, Linköping UniversityDepartment of Emergency Medicine in Linköping, Department of Biomedical and Clinical Sciences, Linköping UniversityAbstract Background The capillary refill test is widely used in pediatric emergency medicine and critical care although its validity and reliability are debated. Naked eye estimation is the recommended method for capillary refill time (CR time) assessment. The goal of this study was to compare naked eye estimations of the CR time in pediatric patients to quantified capillary refill time (qCR time) using polarized reflectance imaging as an objective reference, and to investigate interobserver and intra-observer consistency of naked eye assessments of CR time. Method A film sequence comprising videos of capillary refill tests from 15 emergency pediatric patients was shown under standardized conditions to 62 observers (pediatricians, nurses, assistant nurses, and medical secretaries). The observers’ estimations of CR time in seconds and in descriptive categorizations were compared to objectively derived qCR time. Three tests were shown twice without the observers’ knowledge. Results There was poor interobserver agreement in all professions, with limits of agreement ranging from 1.17 s (assistant nurses) to 2.00 s (secretaries). Intra-observer agreement for estimations of both time and descriptive categorizations was limited. The correlation between naked eye assessments and qCR time was weak. Conclusion This study shows that naked eye assessment of CR time in children is highly subjective with poor reproducibility in pediatric nurses and pediatricians, as well as in comparison to a quantitative method. Based on the lack of both inter- and intra-observer consistency in the assessments, these findings suggest that CR time assessed by naked eye should be questioned as a routine test in pediatric emergencies.https://doi.org/10.1186/s12873-025-01204-0Capillary refillEmergency carePediatricsMicrocirculation
spellingShingle Frida Meyer
Jonatan Stahre
Joakim Henricson
Daniel B. Wilhelms
Can we trust naked eye assessments of the capillary refill test in children? An experimental study
BMC Emergency Medicine
Capillary refill
Emergency care
Pediatrics
Microcirculation
title Can we trust naked eye assessments of the capillary refill test in children? An experimental study
title_full Can we trust naked eye assessments of the capillary refill test in children? An experimental study
title_fullStr Can we trust naked eye assessments of the capillary refill test in children? An experimental study
title_full_unstemmed Can we trust naked eye assessments of the capillary refill test in children? An experimental study
title_short Can we trust naked eye assessments of the capillary refill test in children? An experimental study
title_sort can we trust naked eye assessments of the capillary refill test in children an experimental study
topic Capillary refill
Emergency care
Pediatrics
Microcirculation
url https://doi.org/10.1186/s12873-025-01204-0
work_keys_str_mv AT fridameyer canwetrustnakedeyeassessmentsofthecapillaryrefilltestinchildrenanexperimentalstudy
AT jonatanstahre canwetrustnakedeyeassessmentsofthecapillaryrefilltestinchildrenanexperimentalstudy
AT joakimhenricson canwetrustnakedeyeassessmentsofthecapillaryrefilltestinchildrenanexperimentalstudy
AT danielbwilhelms canwetrustnakedeyeassessmentsofthecapillaryrefilltestinchildrenanexperimentalstudy