Measurement and analysis of dose uniformity ratio for pile-up irradiation in static state in irradiation room

The quality of three irradiation techniques for five irradiated products has been studied using the measurement of dose ununiformity in product box irradiated. The results were as follows: 1) The range of dose ununiformity was from 1.36 to 1.67 with changing the position from the top to the bottom a...

Full description

Saved in:
Bibliographic Details
Main Authors: SHI Jian-jun, CHEN Hui
Format: Article
Language:English
Published: Zhejiang University Press 2001-01-01
Series:浙江大学学报. 农业与生命科学版
Subjects:
Online Access:https://www.academax.com/doi/10.3785/1008-9209.2001.01.0078
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The quality of three irradiation techniques for five irradiated products has been studied using the measurement of dose ununiformity in product box irradiated. The results were as follows: 1) The range of dose ununiformity was from 1.36 to 1.67 with changing the position from the top to the bottom and from the front to the back and it didn't exceeded the dose ununiformity limitation (U&lt;2). This technique can been used to production.2) The dose ununiformity of single face irradiation was 2.67. It exceeded the limitation described, so which can not be used to production.3) The dose ununiformity of single face irradiation in the back rank (two products) were 3.25 and 3.69 respectively, also exceeded the limitation described and can not be used to production. But it can be used as assistant irradiation method for increasing the utilization efficiency of <sup>60</sup>Co.