Patients skin dose measurements during interventional radiological examinations using Gafchromic XR-RV3 FILM

This work is devoted to the assessment of the absorbed dose in the skin of patients undergoing interventional radiological examinations. There is a probability of deterministic effects in the skin of patients due to high doses of radiation during this type of medical examinations. The aim of this wo...

Full description

Saved in:
Bibliographic Details
Main Author: Svetlana S. Sarycheva
Format: Article
Language:English
Published: Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev 2020-01-01
Series:Радиационная гигиена
Subjects:
Online Access:https://www.radhyg.ru/jour/article/view/663
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849240299840208896
author Svetlana S. Sarycheva
author_facet Svetlana S. Sarycheva
author_sort Svetlana S. Sarycheva
collection DOAJ
description This work is devoted to the assessment of the absorbed dose in the skin of patients undergoing interventional radiological examinations. There is a probability of deterministic effects in the skin of patients due to high doses of radiation during this type of medical examinations. The aim of this work was to conduct direct measurements of the absorbed dose in the skin of patients undergoing interventional radiological procedures using special dosimetric radiochromic films Gafchromic XR-RV3 to visualize the distribution of radiation over the patient’s skin surface and to study the possibility of exceeding the threshold values for the deterministic effects in the skin. The paper discusses the features of measurements with GafchromiC XR-RV3 films. The method of film digitization on conventional flatbed scanner and image processing with the ImageJ program was tested. The obtained calibration curve for this type of film was presented. The skin dose distributions for several interventional studies obtained with radiochromic films were presented. The measured value of the maximum absorbed dose in the skin for four of the fourteen analyzed procedures exceeded the threshold value of the absorbed dose for the occurrence of skin erythema in 2 Gy. The highest values of the maximum absorbed dose in the skin were obtained for the coronary angioplasty – 3.2 Gy and for the procedure of embolization of the uterine arteries – 2.9 Gy.
format Article
id doaj-art-67c35c2d61b2495a8b6c7a6bb0742c23
institution Kabale University
issn 1998-426X
language English
publishDate 2020-01-01
publisher Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
record_format Article
series Радиационная гигиена
spelling doaj-art-67c35c2d61b2495a8b6c7a6bb0742c232025-08-20T04:00:39ZengSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. RamzaevРадиационная гигиена1998-426X2020-01-01124899510.21514/1998-426X-2019-12-4-89-95625Patients skin dose measurements during interventional radiological examinations using Gafchromic XR-RV3 FILMSvetlana S. Sarycheva0Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-BeingThis work is devoted to the assessment of the absorbed dose in the skin of patients undergoing interventional radiological examinations. There is a probability of deterministic effects in the skin of patients due to high doses of radiation during this type of medical examinations. The aim of this work was to conduct direct measurements of the absorbed dose in the skin of patients undergoing interventional radiological procedures using special dosimetric radiochromic films Gafchromic XR-RV3 to visualize the distribution of radiation over the patient’s skin surface and to study the possibility of exceeding the threshold values for the deterministic effects in the skin. The paper discusses the features of measurements with GafchromiC XR-RV3 films. The method of film digitization on conventional flatbed scanner and image processing with the ImageJ program was tested. The obtained calibration curve for this type of film was presented. The skin dose distributions for several interventional studies obtained with radiochromic films were presented. The measured value of the maximum absorbed dose in the skin for four of the fourteen analyzed procedures exceeded the threshold value of the absorbed dose for the occurrence of skin erythema in 2 Gy. The highest values of the maximum absorbed dose in the skin were obtained for the coronary angioplasty – 3.2 Gy and for the procedure of embolization of the uterine arteries – 2.9 Gy.https://www.radhyg.ru/jour/article/view/663interventional radiologyfilm dosimetrydeterministic effectsabsorbed dose in the skin
spellingShingle Svetlana S. Sarycheva
Patients skin dose measurements during interventional radiological examinations using Gafchromic XR-RV3 FILM
Радиационная гигиена
interventional radiology
film dosimetry
deterministic effects
absorbed dose in the skin
title Patients skin dose measurements during interventional radiological examinations using Gafchromic XR-RV3 FILM
title_full Patients skin dose measurements during interventional radiological examinations using Gafchromic XR-RV3 FILM
title_fullStr Patients skin dose measurements during interventional radiological examinations using Gafchromic XR-RV3 FILM
title_full_unstemmed Patients skin dose measurements during interventional radiological examinations using Gafchromic XR-RV3 FILM
title_short Patients skin dose measurements during interventional radiological examinations using Gafchromic XR-RV3 FILM
title_sort patients skin dose measurements during interventional radiological examinations using gafchromic xr rv3 film
topic interventional radiology
film dosimetry
deterministic effects
absorbed dose in the skin
url https://www.radhyg.ru/jour/article/view/663
work_keys_str_mv AT svetlanassarycheva patientsskindosemeasurementsduringinterventionalradiologicalexaminationsusinggafchromicxrrv3film