Room Temperature Field Characteristics with Multi- air-conditioner in Operation

The experiments were conducted to determine the influences of some factors on the air flow fields and temperature distributions in an air-conditioned room.The results show that the positioning of the air-conditioners influences the cooling rate dominantly and the air discharging angle and speed also...

Full description

Saved in:
Bibliographic Details
Main Authors: 吴丹尼, 陈伟, 萧峰
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2006-01-01
Series:Zhileng xuebao
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2006.03.005
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849705405435871232
author 吴丹尼
陈伟
萧峰
author_facet 吴丹尼
陈伟
萧峰
author_sort 吴丹尼
collection DOAJ
description The experiments were conducted to determine the influences of some factors on the air flow fields and temperature distributions in an air-conditioned room.The results show that the positioning of the air-conditioners influences the cooling rate dominantly and the air discharging angle and speed also have certain effect.In particular,the average indoor temperature decreases faster when the two air conditioners are at opposite ends of the room long side and the air discharges in the horizontal direction.Moreover,the air temperature drops more slowly when the two air conditioners stand corner to corner in the cross.In addition,the temperature field has the minimum temperature difference when cool air issues at an angle of 120 degrees.
format Article
id doaj-art-67930d36eadc4166b58e4043ff068333
institution DOAJ
issn 0253-4339
language zho
publishDate 2006-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-67930d36eadc4166b58e4043ff0683332025-08-20T03:16:29ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392006-01-0166524253Room Temperature Field Characteristics with Multi- air-conditioner in Operation吴丹尼陈伟萧峰The experiments were conducted to determine the influences of some factors on the air flow fields and temperature distributions in an air-conditioned room.The results show that the positioning of the air-conditioners influences the cooling rate dominantly and the air discharging angle and speed also have certain effect.In particular,the average indoor temperature decreases faster when the two air conditioners are at opposite ends of the room long side and the air discharges in the horizontal direction.Moreover,the air temperature drops more slowly when the two air conditioners stand corner to corner in the cross.In addition,the temperature field has the minimum temperature difference when cool air issues at an angle of 120 degrees.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2006.03.005
spellingShingle 吴丹尼
陈伟
萧峰
Room Temperature Field Characteristics with Multi- air-conditioner in Operation
Zhileng xuebao
title Room Temperature Field Characteristics with Multi- air-conditioner in Operation
title_full Room Temperature Field Characteristics with Multi- air-conditioner in Operation
title_fullStr Room Temperature Field Characteristics with Multi- air-conditioner in Operation
title_full_unstemmed Room Temperature Field Characteristics with Multi- air-conditioner in Operation
title_short Room Temperature Field Characteristics with Multi- air-conditioner in Operation
title_sort room temperature field characteristics with multi air conditioner in operation
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2006.03.005
work_keys_str_mv AT wúdānní roomtemperaturefieldcharacteristicswithmultiairconditionerinoperation
AT chénwěi roomtemperaturefieldcharacteristicswithmultiairconditionerinoperation
AT xiāofēng roomtemperaturefieldcharacteristicswithmultiairconditionerinoperation