A Method for Searching for Defective Solar Panels in Telemetry Data of a Power Plant Based on the Results of a Digital Twin
Searching for faulty, and therefore operating in abnormal mode, solar panels at a power plant is an urgent task in the context of the development and growth of the share of solar energy in electricity generation. The research is aimed at developing and evaluating the effectiveness of a new methodolo...
Saved in:
| Main Author: | |
|---|---|
| Format: | Article |
| Language: | Russian |
| Published: |
Educational institution «Belarusian State University of Informatics and Radioelectronics»
2024-01-01
|
| Series: | Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki |
| Subjects: | |
| Online Access: | https://doklady.bsuir.by/jour/article/view/3799 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849398476388958208 |
|---|---|
| author | K. S. Dzik |
| author_facet | K. S. Dzik |
| author_sort | K. S. Dzik |
| collection | DOAJ |
| description | Searching for faulty, and therefore operating in abnormal mode, solar panels at a power plant is an urgent task in the context of the development and growth of the share of solar energy in electricity generation. The research is aimed at developing and evaluating the effectiveness of a new methodology and software algorithm for searching for anomalies in the operation of solar panels based on the results of a digital twin created and trained using telemetry data from a solar power plant. The methodology is based on studies of deviations in power values at the point of maximum efficient operation of the solar panel, calculated by the digital twin, from the average statistical values for the power plant. Using the proposed methodology, over six months of direct observations, 16 anomalies in the operation of the solar panels of the power plant were discovered and confirmed. It has been established that when analyzing deviations of normalized power values at the maximum power point PN, it is possible to detect solar panels that have defects or operate with loss of efficiency. |
| format | Article |
| id | doaj-art-670ecbac4d7e45ba9dd39f27d711a762 |
| institution | Kabale University |
| issn | 1729-7648 |
| language | Russian |
| publishDate | 2024-01-01 |
| publisher | Educational institution «Belarusian State University of Informatics and Radioelectronics» |
| record_format | Article |
| series | Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki |
| spelling | doaj-art-670ecbac4d7e45ba9dd39f27d711a7622025-08-20T03:38:35ZrusEducational institution «Belarusian State University of Informatics and Radioelectronics»Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki1729-76482024-01-0121611312010.35596/1729-7648-2023-21-6-113-1201959A Method for Searching for Defective Solar Panels in Telemetry Data of a Power Plant Based on the Results of a Digital TwinK. S. Dzik0Belarusian State University of Informatics and RadioelectronicsSearching for faulty, and therefore operating in abnormal mode, solar panels at a power plant is an urgent task in the context of the development and growth of the share of solar energy in electricity generation. The research is aimed at developing and evaluating the effectiveness of a new methodology and software algorithm for searching for anomalies in the operation of solar panels based on the results of a digital twin created and trained using telemetry data from a solar power plant. The methodology is based on studies of deviations in power values at the point of maximum efficient operation of the solar panel, calculated by the digital twin, from the average statistical values for the power plant. Using the proposed methodology, over six months of direct observations, 16 anomalies in the operation of the solar panels of the power plant were discovered and confirmed. It has been established that when analyzing deviations of normalized power values at the maximum power point PN, it is possible to detect solar panels that have defects or operate with loss of efficiency.https://doklady.bsuir.by/jour/article/view/3799solar panelnormalized power valueanomaly searchsolar panel chainsolar power plantmaximum power point |
| spellingShingle | K. S. Dzik A Method for Searching for Defective Solar Panels in Telemetry Data of a Power Plant Based on the Results of a Digital Twin Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki solar panel normalized power value anomaly search solar panel chain solar power plant maximum power point |
| title | A Method for Searching for Defective Solar Panels in Telemetry Data of a Power Plant Based on the Results of a Digital Twin |
| title_full | A Method for Searching for Defective Solar Panels in Telemetry Data of a Power Plant Based on the Results of a Digital Twin |
| title_fullStr | A Method for Searching for Defective Solar Panels in Telemetry Data of a Power Plant Based on the Results of a Digital Twin |
| title_full_unstemmed | A Method for Searching for Defective Solar Panels in Telemetry Data of a Power Plant Based on the Results of a Digital Twin |
| title_short | A Method for Searching for Defective Solar Panels in Telemetry Data of a Power Plant Based on the Results of a Digital Twin |
| title_sort | method for searching for defective solar panels in telemetry data of a power plant based on the results of a digital twin |
| topic | solar panel normalized power value anomaly search solar panel chain solar power plant maximum power point |
| url | https://doklady.bsuir.by/jour/article/view/3799 |
| work_keys_str_mv | AT ksdzik amethodforsearchingfordefectivesolarpanelsintelemetrydataofapowerplantbasedontheresultsofadigitaltwin AT ksdzik methodforsearchingfordefectivesolarpanelsintelemetrydataofapowerplantbasedontheresultsofadigitaltwin |